SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Appelgren M.) srt2:(2005-2009)"

Sökning: WFRF:(Appelgren M.) > (2005-2009)

  • Resultat 1-8 av 8
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Appelgren, Patrik, et al. (författare)
  • Parametric studies of an electrohydrodynamic plasma actuator for boundary layer flow control
  • 2009
  • Ingår i: PPC '09. IEEE Pulsed Power Conference, 2009. - : IEEE. - 9781424440658 ; , s. 1069-1074
  • Konferensbidrag (refereegranskat)abstract
    • An electrohydrodynamic plasma actuator can be used as an aerodynamic flow control device. A plasma actuator is realised as a surface-mounted dielectric barrier discharge (DBD) that transfers directed energy from ions in the discharge to the surrounding air. Parametric studies have been performed in order to investigate the relative efficiency in terms of electrical power into the actuator versus mechanical power in the generated boundary flow. The parametric study includes variations of the applied driving voltage and frequency as well as different electrode and dielectric materials. It is found that, within the range tested, for each value of electrical power into the actuator there exists an optimum driving frequency in terms of boundary layer flow velocity. It is also found that the same trend seems to be true when analyzing electric to mechanical efficiency of the device, i.e. for a given input power there exists an optimum driving frequency that produces the highest efficiency. However, this peak in efficiency of the actuator lies on the edge of the parametric space tested so that further experiments are needed to validate these results.
  •  
3.
  • Appelgren, Patrik, et al. (författare)
  • Small helical magnetic flux compression generators : Experiments and analysis
  • 2007
  • Ingår i: PPPS-2007 - Pulsed Power Plasma Science 2007. - : IEEE. - 1424409144 - 9781424409143 ; , s. 1151-1154
  • Konferensbidrag (refereegranskat)abstract
    • This paper presents experimental results with helical magnetic flux-compression generators (FCGs). FCGs convert the chemical energy bond in explosives into electric energy. The generator had an initial inductance of 23 μH and was operated into a load of 0.2 μH. The generator is charged with 0.27 kg of high-explosives (PBXN-5). Various types of diagnostics were used to monitor the operation of the generator, including current probes, optical fibres, and piezo gauges. The results are analysed and the expansion of the armature compared with hydrodynamic simulations.
  •  
4.
  •  
5.
  • Appelgren, Patrik, et al. (författare)
  • Small Helical Magnetic Flux-Compression Generators : Experiments and Analysis
  • 2008
  • Ingår i: IEEE Transactions on Plasma Science. - 0093-3813 .- 1939-9375. ; 36:5, s. 2673-2683
  • Tidskriftsartikel (refereegranskat)abstract
    • In order to gain experience in explosive pulsed power and to provide experimental data for modeling, a small high-explosive-driven helical magnetic flux-compression generator (FCG) was designed at the Swedish Defence Research Agency (FOI). The generator, of which three have been built, has an overall length of 300 mm and a diameter of 70 mm. It could serve as the energy source in a pulse-forming network to generate high power pulses for various loads. This paper presents the design of, and tests with, this helical FCG. The generator had an initial inductance of 23 mu H and was operated into a load of 0.2 mu H. The generator is charged with 0.27 kg of high explosives (PBXN-5). Various types of diagnostics were used to monitor the operation of the generator, including current probes, optical fibers, and piezo gauges. With seed currents of 5.7 and 11.2 kA, final currents of 269 and 436 kA were obtained, corresponding to current amplification factors of 47 and 39. The peak of the current was reached about 30 mu s after the time of crowbar. The two generators showed only small losses in terms of 2 pi-clocking. Using signals from optical fibers, the deflection angle of the armature could be determined to be 10 degrees in good agreement with hydrodynamic simulations of the detonation process and the detonation velocity to be 8.7 km/s in agreement with tabulated value.
  •  
6.
  • Hogberg, Johan, et al. (författare)
  • Phthalate diesters and their metabolites in human breast milk, blood or serum, and urine as biomarkers of exposure in vulnerable populations
  • 2008
  • Ingår i: Journal of Environmental Health Perspectives. - : Environmental Health Perspectives. - 0091-6765 .- 1552-9924. ; 116:3, s. 334-339
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Phthalates may pose a risk for perinatal developmental effects. An important question relates to the choice of suitable biological matrices for assessing exposure during this period. OBJECTIVES: This study was designed to measure the concentrations of phthalate diesters or their metabolites in breast milk, blood or serum, and urine and to evaluate their suitability for assessing perinatal exposure to phthalates. METHODS: In 2001, 2-3 weeks after delivery, 42 Swedish primipara provided breast milk, blood, and urine samples at home. Special care was taken to minimize contamination with phthalates (e.g., use of a special breast milk pump, heat treatment of glassware and needles, addition of phosphoric acid). RESULTS: Phthalate diesters and metabolites in milk and blood or serum, if detected, were present at concentrations close to the limit of detection. By contrast, most phthalate metabolites were detectable in urine at concentrations comparable to those from the general population in the United States and in Germany. No correlations existed between urine concentrations and those found in milk or blood/serum for single phthalate metabolites. Our data are at odds with a previous study documenting frequent detection and comparatively high concentrations of phthalate metabolites in Finnish and Danish mothers' milk. CONCLUSIONS: Concentrations of phthalate metabolites in urine are more informative than those in milk or serum. Furthermore, collection of milk or blood may be associated with discomfort and potential technical problems such as contamination (unless oxidative metabolites are measured). Although urine is a suitable matrix for health-related phthalate monitoring, urinary concentrations in nursing mothers cannot be used to estimate exposure to phthalates through milk ingestion by breast-fed infants.
  •  
7.
  • Novac, Bucur M., et al. (författare)
  • A 10-GW pulsed power supply for HPM sources
  • 2006
  • Ingår i: IEEE TRANS PLASMA SCI. ; , s. 1814-1821
  • Konferensbidrag (refereegranskat)abstract
    • A research activity involving the detailed consideration of novel high-voltage transformers for pulsed-power applications has recently begun at Loughborough University. Although the main goal is the demonstration of a compact and lightweight unit employing magnetic insulation under vacuum conditions, the initial stage of the work is directed toward the development of a conventional air-cored transformer as a main component in a compact power supply for high power microwave sources. In cooperation with the Swedish Defence Research Agency (FOI), the power supply has been tested with a microwave source of the vircator type. The power generator for the system uses a 70-kJ/25-kV capacitor bank and an exploding wire array to generate a 150-kV voltage pulse in the primary circuit of a transformer. A pressurized SF6 spark gap in the secondary circuit sharpens the high-voltage output so that pulses approaching 500 kV and with a rise time well below 100 ns are generated on a 20-Omega high-power resistors With the peak power in excess of 10 GW. Experimental results are presented from final testing of the system, where a reflex triode vircator replaces the 20-Omega resistor. Measurements of the microwave emission using free-field sensors are presented, and comments are made with the microwave emission from the same vircator when powered by a Marx generator at FOI.
  •  
8.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-8 av 8

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy