SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Arbuckle S) srt2:(2010-2014)"

Sökning: WFRF:(Arbuckle S) > (2010-2014)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Medin, J., et al. (författare)
  • Development and Validation of the AFSymp (TM) : An Atrial Fibrillation-Specific Measure of Patient-Reported Symptoms
  • 2014
  • Ingår i: Patient-Patient Centered Outcomes Research. - : Springer Science and Business Media LLC. - 1178-1653 .- 1178-1661. ; 7:3, s. 319-327
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Patients with atrial fibrillation (AF) can be severely incapacitated by symptoms, but validated symptom measures are lacking. The aim of this study was to develop an AF-specific symptom questionnaire (AFSymp(TM)). Methods Following a literature review, qualitative interviews with 91 patients (United States [US], n = 30; United Kingdom [UK], n = 16; France, n = 15; Germany, n = 15; Japan, n = 15) with paroxysmal, persistent, and permanent AF were conducted to identify emergent concepts and to develop the items and response options for the AFSymp(TM). Clinical experts (n = 21) in the US, the UK, France, Germany, and Japan provided feedback on the most clinically relevant symptoms via an email survey. Cognitive interviews with 30 patients were conducted to evaluate content validity. A prospective, observational, psychometric evaluation study (n = 313) consisting of two study visits was performed at 32 sites across the US. Results After item reduction, the AFSymp(TM) consisted of 11 items with a 1-week recall period. Exploratory and confirmatory factor analysis resulted in three subscales (heart symptoms, tiredness, chest discomfort) and two items: dizziness and shortness of breath. Internal consistency was strong across subscales (Cronbach's a 0.82-0.91). The test-retest reliability of items and subscales was acceptable (intra-class correlation [ICC] 0.58-0.78). The reproducibility of the single global score was strong (ICC 0.78). The construct and known-groups validity was acceptable. Conclusion The AFSymp(TM) demonstrates evidence of reliability and validity as a comprehensive measure of AF symptoms that can be used to assess patient outcomes in clinical and research settings. More research is needed to evaluate the instrument's responsiveness.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy