SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Böhlen T. T.) "

Sökning: WFRF:(Böhlen T. T.)

  • Resultat 1-7 av 7
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Pleskac, R., et al. (författare)
  • The FIRST experiment at GSI
  • 2012
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 678, s. 130-138
  • Tidskriftsartikel (refereegranskat)abstract
    • The FIRST (Fragmentation of Ions Relevant for Space and Therapy) experiment at the SIS accelerator of GSl laboratory in Darmstadt has been designed for the measurement of ion fragmentation crosssections at different angles and energies between 100 and 1000 MeV/nucleon. Nuclear fragmentation processes are relevant in several fields of basic research and applied physics and are of particular interest for tumor therapy and for space radiation protection applications. The start of the scientific program of the FIRST experiment was on summer 2011 and was focused on the measurement of 400 MeV/nucleon C-12 beam fragmentation on thin (8 mm) graphite target. The detector is partly based on an already existing setup made of a dipole magnet (ALADiN). a time projection chamber (TP-MUSIC IV), a neutron detector (LAND) and a time of flight scintillator system (TOFWALL). This pre-existing setup has been integrated with newly designed detectors in the Interaction Region, around the carbon target placed in a sample changer. The new detectors are a scintillator Start Counter, a Beam Monitor drift chamber, a silicon Vertex Detector and a Proton Tagger scintillator system optimized for the detection of light fragments emitted at large angles. In this paper we review the experimental setup, then we present the simulation software, the data acquisition system and finally the trigger strategy of the experiment.
  •  
2.
  • Toppi, M., et al. (författare)
  • Measurement of fragmentation cross sections of C-12 ions on a thin gold target with the FIRST apparatus
  • 2016
  • Ingår i: Physical Review C. - 2469-9985 .- 2469-9993. ; 93:6
  • Tidskriftsartikel (refereegranskat)abstract
    • A detailed knowledge of the light ions interaction processes with matter is of great interest in basic and applied physics. As an example, particle therapy and space radioprotection require highly accurate fragmentation cross-section measurements to develop shielding materials and estimate acute and late health risks for manned missions in space and for treatment planning in particle therapy. The Fragmentation of Ions Relevant for Space and Therapy experiment at the Helmholtz Center for Heavy Ion research (GSI) was designed and built by an international collaboration from France, Germany, Italy, and Spain for studying the collisions of a C-12 ion beam with thin targets. The collaboration's main purpose is to provide the double-differential cross-section measurement of carbon-ion fragmentation at energies that are relevant for both tumor therapy and space radiation protection applications. Fragmentation cross sections of light ions impinging on a wide range of thin targets are also essential to validate the nuclear models implemented in MC simulations that, in such an energy range, fail to reproduce the data with the required accuracy. This paper presents the single differential carbon-ion fragmentation cross sections on a thin gold target, measured as a function of the fragment angle and kinetic energy in the forward angular region (theta less than or similar to 6 degrees), aiming to provide useful data for the benchmarking of the simulation softwares used in light ions fragmentation applications. The C-12 ions used in the measurement were accelerated at the energy of 400 MeV/nucleon by the SIS (heavy ion synchrotron) GSI facility.
  •  
3.
  • Böhlen, Till Tobias, et al. (författare)
  • A Monte Carlo-based treatment-planning tool for ion beam therapy
  • 2013
  • Ingår i: Journal of radiation research. - : Oxford University Press (OUP). - 0449-3060 .- 1349-9157. ; 54, s. 77-81
  • Tidskriftsartikel (refereegranskat)abstract
    • Ion beam therapy, as an emerging radiation therapy modality, requires continuous efforts to develop and improve tools for patient treatment planning (TP) and research applications. Dose and fluence computation algorithms using the Monte Carlo (MC) technique have served for decades as reference tools for accurate dose computations for radiotherapy. In this work, a novel MC-based treatment-planning (MCTP) tool for ion beam therapy using the pencil beam scanning technique is presented. It allows single-field and simultaneous multiple-fields optimization for realistic patient treatment conditions and for dosimetric quality assurance for irradiation conditions at state-of-the-art ion beam therapy facilities. It employs iterative procedures that allow for the optimization of absorbed dose and relative biological effectiveness (RBE)-weighted dose using radiobiological input tables generated by external RBE models. Using a re-implementation of the local effect model (LEM), the MCTP tool is able to perform TP studies using ions with atomic numbers Z < 8. Example treatment plans created with the MCTP tool are presented for carbon ions in comparison with a certified analytical treatment-planning system. Furthermore, the usage of the tool to compute and optimize mixed-ion treatment plans, i.e. plans including pencil beams of ions with different atomic numbers, is demonstrated. The tool is aimed for future use in research applications and to support treatment planning at ion beam facilities.
  •  
4.
  • Böhlen, Till Tobias, et al. (författare)
  • Investigating the robustness of ion beam therapy treatment plans to uncertainties in biological treatment parameters
  • 2012
  • Ingår i: Physics in Medicine and Biology. - : IOP Publishing. - 0031-9155 .- 1361-6560. ; 57:23, s. 7983-8004
  • Tidskriftsartikel (refereegranskat)abstract
    • Uncertainties in determining clinically-used relative biological effectiveness (RBE) values for ion beam therapy carry the risk of absolute and relative misestimations of RBE-weighted doses for clinical scenarios. The present study assesses the consequences of hypothetical misestimations of input parameters to the RBE modelling for carbon ion treatment plans by a variational approach. The impact of the variations on resulting cell survival and RBE values is evaluated as a function of the remaining ion range. In addition, the sensitivity to misestimations in RBE modelling is compared for single fields and two opposed fields using differing optimization criteria. It is demonstrated for single treatment fields that moderate variations (up to ±50%) of representative nominal input parameters for four tumours result mainly in a misestimation of the RBE-weighted dose in the planning target volume (PTV) by a constant factor and only smaller RBE-weighted dose gradients. Ensuring a more uniform radiation quality in the PTV eases the clinical importance of uncertainties in the radiobiological treatment parameters as for such a condition uncertainties tend to result only in a systematic misestimation of RBE-weighted dose in the PTV by a constant factor. Two opposed carbon ion fields with a constant RBE in the PTV are found to result in rather robust conditions. Treatments using two ion species may be used to achieve a constant RBE in the PTV irrespective of the size and depth of the spread-out Bragg peak.
  •  
5.
  • Mairani, A., et al. (författare)
  • A Monte Carlo-based treatment planning tool for proton therapy
  • 2012
  • Annan publikation (övrigt vetenskapligt/konstnärligt)abstract
    • In the field of radiotherapy Monte Carlo (MC) particle transport calculations are recognized for their superior accuracy in predicting dose and fluence distributions in patient geometries compared to analytical algorithms which are generally used for treatment planning due to their shorter execution time. In the present work, a newly-developed MC-based treatment planning (MCTP) tool for proton therapy is proposed to support treatment planning studies and research applications. It allows for single-field and simultaneous multiple-field optimization in realistic treatment scenarios and is based on the MC code FLUKA. Relative biological effectiveness (RBE)-weighted dose is optimized either with the common approach using a constant RBE of 1.1 or using a variable RBE according to radiobiological input tables. A validated reimplementation of the local effect model was used in this work to generate radiobiological input tables. Examples of treatment plans in water phantoms and in patient-CT geometries are presented for clinical treatment parameters as used at the CNAO (Italian Center for Hadrontherapy) facility. To conclude, a versatile MCTP tool for proton therapy was developed and validated for realistic patient treatment scenarios and dosimetric measurements. It is aimed to be used in future for research and to support treatment planning at state-of-the-art ion beam therapy facilities.
  •  
6.
  • Mairani, A., et al. (författare)
  • A Monte Carlo-based treatment planning tool for proton therapy
  • 2013
  • Ingår i: Physics in Medicine and Biology. - : IOP Publishing. - 0031-9155 .- 1361-6560. ; 58:8, s. 2471-2490
  • Tidskriftsartikel (refereegranskat)abstract
    • In the field of radiotherapy, Monte Carlo (MC) particle transport calculations are recognized for their superior accuracy in predicting dose and fluence distributions in patient geometries compared to analytical algorithms which are generally used for treatment planning due to their shorter execution times. In this work, a newly developed MC-based treatment planning (MCTP) tool for proton therapy is proposed to support treatment planning studies and research applications. It allows for single-field and simultaneous multiple-field optimization in realistic treatment scenarios and is based on the MC code FLUKA. Relative biological effectiveness (RBE)-weighted dose is optimized either with the common approach using a constant RBE of 1.1 or using a variable RBE according to radiobiological input tables. A validated reimplementation of the local effect model was used in this work to generate radiobiological input tables. Examples of treatment plans in water phantoms and in patient-CT geometries together with an experimental dosimetric validation of the plans are presented for clinical treatment parameters as used at the Italian National Center for Oncological Hadron Therapy. To conclude, a versatile MCTP tool for proton therapy was developed and validated for realistic patient treatment scenarios against dosimetric measurements and commercial analytical TP calculations. It is aimed to be used in future for research and to support treatment planning at state-of-the-art ion beam therapy facilities.
  •  
7.
  • Rescigno, R., et al. (författare)
  • Performance of the reconstruction algorithms of the FIRST experiment pixel sensors vertex detector
  • 2014
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 767, s. 34-40
  • Tidskriftsartikel (refereegranskat)abstract
    • Hadrontherapy treatments use charged particles (e.g. protons and carbon ions) to treat tumors. During a therapeutic treatment with carbon ions, the beam undergoes nuclear fragmentation processes giving rise to significant yields of secondary charged particles. An accurate prediction of these production rates is necessary to estimate precisely the dose deposited into the tumours and the surrounding healthy tissues. Nowadays, a limited set of double differential carbon fragmentation cross-section is available. Experimental data are necessary to benchmark Monte Carlo simulations for their use in hadrontherapy. The purpose of the FIRST experiment is to study nuclear fragmentation processes of ions with kinetic energy in the range from 100 to 1000 MeV/u. Tracks are reconstructed using information from a pixel silicon detector based on the CMOS technology. The performances achieved using this device for hadrontherapy purpose are discussed. For each reconstruction step (clustering, tracking and vertexing), different methods are implemented. The algorithm performances and the accuracy on reconstructed observables are evaluated on the basis of simulated and experimental data.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-7 av 7

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy