SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Batista P.) srt2:(2005-2009)"

Search: WFRF:(Batista P.) > (2005-2009)

  • Result 1-2 of 2
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Batista, P.D., et al. (author)
  • Acousto-electric single-photon detector
  • 2007
  • In: Proceedings of SPIE - The International Society for Optical Engineering. - : SPIE. - 0277-786X .- 1996-756X. ; 6583, s. 658304-
  • Journal article (peer-reviewed)abstract
    • We propose a novel concept for a semiconductor-based single-photon detector for quantum information processing, which is capable of discriminating the number of photons in a light pulse. The detector exploits the charge transport by a surface acoustic wave (SAW) in order to combine a large photon absorption area (thus providing high photon collection efficiency) with a microscopic charge detection area, where the photo generated charge is detected with resolution at the single electron level using single electron transistors (SETs). We present preliminary results on acoustic transport measured in a prototype for the detector as well as on the fabrication of radio-frequency single-electron transistors (RFSETs) for charge detection. The photon detector is a particular example of acousto-electric nanocircuits that are expected to be able to control both the spatial and the spin degrees of freedom of single electrons. If realized, these circuits will contribute substantially to a scalable quantum information technology.
  •  
2.
  • Costa, Eduardo L V, et al. (author)
  • Bedside estimation of recruitable alveolar collapse and hyperdistension by electrical impedance tomography
  • 2009
  • In: Intensive Care Medicine. - : Springer Science and Business Media LLC. - 0342-4642 .- 1432-1238. ; 35:6, s. 1132-1137
  • Journal article (peer-reviewed)abstract
    • OBJECTIVE: To present a novel algorithm for estimating recruitable alveolar collapse and hyperdistension based on electrical impedance tomography (EIT) during a decremental positive end-expiratory pressure (PEEP) titration. DESIGN: Technical note with illustrative case reports. SETTING: Respiratory intensive care unit. PATIENT: Patients with acute respiratory distress syndrome. INTERVENTIONS: Lung recruitment and PEEP titration maneuver. MEASUREMENTS AND RESULTS: Simultaneous acquisition of EIT and X-ray computerized tomography (CT) data. We found good agreement (in terms of amount and spatial location) between the collapse estimated by EIT and CT for all levels of PEEP. The optimal PEEP values detected by EIT for patients 1 and 2 (keeping lung collapse <10%) were 19 and 17 cmH2O, respectively. Although pointing to the same non-dependent lung regions, EIT estimates of hyperdistension represent the functional deterioration of lung units, instead of their anatomical changes, and could not be compared directly with static CT estimates for hyperinflation. CONCLUSIONS: We described an EIT-based method for estimating recruitable alveolar collapse at the bedside, pointing out its regional distribution. Additionally, we proposed a measure of lung hyperdistension based on regional lung mechanics.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-2 of 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view