SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Bauer A) srt2:(2000-2004)"

Sökning: WFRF:(Bauer A) > (2000-2004)

  • Resultat 1-10 av 31
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Abt, I, et al. (författare)
  • Inclusive V-0 production cross sections from 920 GeV fixed target proton-nucleus collisions
  • 2003
  • Ingår i: European Physical Journal C. Particles and Fields. - : Springer Science and Business Media LLC. - 1434-6044. ; 29:2, s. 181-190
  • Tidskriftsartikel (refereegranskat)abstract
    • Inclusive differential cross sections dsigma(pA)/dx(F) and dsigma(pA)/dp(t)(2) for the production of K-S(0), Lambda, and (&ULambda;) over bar particles are measured at HERA in proton-induced reactions on C, Al, Ti, and W targets. The incident beam energy is 920 GeV, corresponding to roots = 41.6 GeV in the proton-nucleon system. The ratios of differential cross sections dsigma(pA)(K-S(0))/dsigma(pA)(Lambda) and dsigma(pA)((&ULambda;) over bar)/dsigma(pA) (Lambda) are measured to be 6.2 +/- 0.5 and 0.66 +/- 0.07, respectively, for x(F) approximate to -0.06. No significant dependence upon the target material is observed. Within errors, the slopes of the transverse momentum distributions da,Ald t also show no significant dependence upon the target material. The dependence of the extrapolated total cross sections sigma(pA) on the atomic mass A of the target material is discussed, and the deduced cross sections per nucleon sigma(pN) are compared with results obtained at other energies.
  •  
2.
  • Abt, I, et al. (författare)
  • Measurement of the b(b)over-bar production cross section in 920 GeV fixed-target proton-nucleus collisions
  • 2003
  • Ingår i: European Physical Journal C. Particles and Fields. - : Springer Science and Business Media LLC. - 1434-6044. ; 26:3, s. 345-355
  • Tidskriftsartikel (refereegranskat)abstract
    • Using the HERA-B detector, the b (b) over bar production cross section has been measured in 920 GeV proton collisions on carbon and titanium targets. The b (b) over bar production was tagged via inclusive bottom quark decays into J/psi by exploiting the longitudinal separation of J/psi --> l(+)l(-) decay vertices from the primary proton-nucleus interaction. Both e(+)e(-) and mu(+)mu(-) channels have been reconstructed and the combined analysis yields the cross section sigma(b (b) over bar) = 32(-12)(+14)(stat) (+6)(-7)(sys) nb/nucleon.
  •  
3.
  • Adler, SS, et al. (författare)
  • Double helicity asymmetry in inclusive midrapidity pi(0) production for polarized p+p collisions at root s=200 GeV
  • 2004
  • Ingår i: Physical Review Letters. - 1079-7114. ; 93:20: 202002
  • Tidskriftsartikel (refereegranskat)abstract
    • We present a measurement of the double longitudinal spin asymmetry in inclusive pi(0) production in polarized proton-proton collisions at roots=200 GeV. The data were taken at the Relativistic Heavy Ion Collider with average beam polarizations of 0.27. The measurements are the first in a program to study the longitudinal spin structure of the proton, using strongly interacting probes, at collider energies. The asymmetry is presented for transverse momenta 1-5 GeV/c at midrapidity, where next-to-leading-order perturbative quantum chromodynamic (NLO pQCD) calculations well describe the unpolarized cross section. The observed asymmetry is small and is compared to a NLO pQCD calculation with a range of polarized gluon distributions.
  •  
4.
  • Lee, A. Y., et al. (författare)
  • Bilateral vs. ipsilateral venography as the primary efficacy outcome measure in thromboprophylaxis clinical trials: a systematic review
  • 2004
  • Ingår i: J Thromb Haemost. - 1538-7933. ; 2:10, s. 1752-9
  • Tidskriftsartikel (refereegranskat)abstract
    • Contrast venography, in combination with symptomatic venous thromboembolism (VTE), is the standard efficacy outcome measure in clinical trials of thromboprophylaxis in major orthopedic surgery. It is uncertain whether performing bilateral venography offers any real advantage over venography of the operated leg alone. This study was undertaken to determine the risk of isolated contralateral deep vein thrombosis (DVT) following major orthopedic surgery and to evaluate whether bilateral venography, rather than venography on the operated leg alone, offers any gain in DVT detection and, thereby, improves efficiency in clinical study design. A systematic review of prospective studies that reported DVT incidence as the primary efficacy outcome based on mandatory bilateral venography in patients undergoing elective hip or knee arthroplasty or hip fracture repair was conducted. Based on the use of bilateral venography as a primary efficacy outcome measure, the incidence of any DVT is 16.7% following total hip replacement, 18.8% after hip fracture repair, and 33.8% after total knee replacement. While DVT risk in the operated leg varies depending on the type of surgery, the risk of isolated DVT in the non-operated leg is approximately 4% to 5% in all three procedures. By increasing the detection of any DVT, the use of bilateral venography reduces required sample size by 16% to 25% compared to ipsilateral venography. In clinical trials evaluating the efficacy of thromboprophylaxis in major orthopedic surgery, bilateral venography reduces the risk of undiagnosed DVT in the non-operated leg and improves the efficiency of study design by substantially reducing the sample size requirement.
  •  
5.
  • Fischer, S. M., et al. (författare)
  • Alignment delays in the N = Z nuclei Kr-72, Sr-76, and Zr-80
  • 2001
  • Ingår i: Physical Review Letters. - 0031-9007 .- 1079-7114. ; 8713:13
  • Tidskriftsartikel (refereegranskat)abstract
    • The ground state rotational bands of the N = Z nuclei Kr-72, Sr-76, and Zr-80 have been extended into the angular momentum region where rotation alignment of particles is normally expected. By measuring the moments of inertia of these bands we have observed a consistent increase in the rotational frequency required to start pair breaking, when compared to neighboring nuclei. Kr-72 shows the most marked effect. It has been widely suggested that these delayed alignments arise from np-pairing correlations. However, alignment frequencies are very sensitive to shape degrees of freedom and normal pairing, so the new experimental observations are still open to interpretation.
  •  
6.
  •  
7.
  •  
8.
  • Gasser, T. Christian, et al. (författare)
  • A three-dimensional finite element model for arterial clamping
  • 2002
  • Ingår i: Journal of Biomechanical Engineering. - : ASME International. - 0148-0731 .- 1528-8951. ; 124:4, s. 355-363
  • Tidskriftsartikel (refereegranskat)abstract
    • Clamp induced injuries of the arterial wall may determine the outcome of surgical procedures. Thus, it is important to investigate the underlying mechanical effects. We present a three-dimensional finite element model, which allows the study of the mechanical response of an artery-treated as a two-layer tube-during arterial clamping. The important residual stresses, which are associated with the load free configuration of the artery, are also considered. In particular, the finite element analysis of the deformation process of a clamped artery and the associated stress distribution is presented. Within the clamping area a zone of axial tensile peak-stresses was identified, which (may) cause intimal and medial injury. This is an additional injury mechanism, which clearly differs from the commonly assumed wall damage occurring due to compression between the jaws of the clamp. The proposed numerical model provides essential insights into the mechanics of the clamping procedure and the associated injury mechanisms. It allows detailed parameter studies on a virtual clamped artery, which can not be performed with other methodologies. This approach has the potential to identify the most appropriate clamps for certain types of arteries and to guide optimal clamp design.
  •  
9.
  • Holzapfel, Gerhard A., et al. (författare)
  • A layer-specific three-dimensional model for the simulation of balloon angioplasty using magnetic resonance imaging and mechanical testing
  • 2002
  • Ingår i: Annals of Biomedical Engineering. - : Springer Science and Business Media LLC. - 0090-6964 .- 1573-9686. ; 30:6, s. 753-767
  • Tidskriftsartikel (refereegranskat)abstract
    • A detailed understanding of the mechanical procedure of balloon angioplasty requires three-dimensional (3D) modeling and efficient numerical simulations. We have developed a 3D model for eight distinct arterial components associated with specific mechanical responses. The 3D geometrical model is based on in vitro magnetic resonance imaging of a human stenotic postmortem artery and is represented by nonuniform rational B-spline surfaces. Mechanical tests of the corresponding vascular tissues provide a fundamental basis for the formulation of large strain constitutive laws, which model the typical anisotropic, highly nonlinear, and inelastic mechanical characteristics under supraphysiological loadings. The 3D finite-element realization considers the balloon-artery interaction and accounts for vessel-specific axial in situ prestretches. 3D stress states of the investigated artery during balloon expansion and stent deployment were analyzed. Furthermore, we studied the changes of the 3D stress state due to model simplifications, which are characterized by neglecting axial in situ prestretch, assuming plane strain states, and isotropic material responses, as commonly utilized in previous works. Since these simplifications lead to maximum stress deviations of up to 600%-where even the stress character may interchange-the associated models are, in general, inappropriate. The proposed approach provides a tool that has the potential (i) to improve procedural protocols and the design of interventional instruments on a lesion-specific basis, and (ii) to determine postangioplasty mechanical environments, which may be correlated with restenosis responses.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 31

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy