SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Baumbach C) srt2:(2017)"

Sökning: WFRF:(Baumbach C) > (2017)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Puri, Rishi, et al. (författare)
  • Transcatheter aortic valve implantation in patients with small aortic annuli using a 20 mm balloon-expanding valve
  • 2017
  • Ingår i: Heart. - : BMJ. - 1355-6037 .- 1468-201X. ; 103, s. 148-153
  • Tidskriftsartikel (refereegranskat)abstract
    • Background While transcatheter aortic valve implantation (TAVI) is established for treating highoperative risk surgical aortic valve replacement candidates, until recently the smallest transcatheter heart valve (THV) measured 23 mm, posing greater risk for annular rupture and THV failure in patients with aortic stenosis (AS) with small aortic annuli (=20 mm). Objectives In the setting of a multicentre registry, we report on the safety, efficacy and early clinical outcomes of the SAPIEN XT 20 mm balloon-expanding THV. Results Among TAVI 55 recipients (n=30 for native AS, n=25 for a valve-in-valve procedure (V-in-V)), median age and Society of Thoracic Surgeons score were 85 (81 to 87) years and 7.8 (4.7 to 12.4)%, respectively. Mean and minimum annular diameters were 19±1 and 17±2 mm, respectively, in native patients with AS, and 17±1 mm (internal diameter) in V-in-V recipients. Successful device implantation rate was 96%, with no procedural-related death. Overall in-hospital-30-day death, stroke and major bleeding rates were 5%, 2% and 9%, respectively. In native AS TAVI recipients, mean transaortic gradient decreased from 54±20 to 12±5 mm Hg ( p<0.001), and from 45±17 to 24±8 mm Hg (p<0.001) in V-in-V recipients. Severe prosthesis-patient mismatch (PPM) rates were 10% and 48% in native AS and V-in-V TAVI recipients, respectively ( p=0.03). Post-TAVI, the rate of moderate aortic regurgitation was 7% and 0% in native AS and V-in-V TAVI recipients, respectively. Conclusions TAVI with the 20 mm SAPIEN XT THV appears safe and technically feasible, with acceptable short-term clinical outcomes and low rates of severe PPM in those with native AS.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy