SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Bech Hanssen Odd 1956) srt2:(2005-2009)"

Sökning: WFRF:(Bech Hanssen Odd 1956) > (2005-2009)

  • Resultat 1-10 av 16
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Wierup, Per, et al. (författare)
  • Moderate mitral regurgitation in patients undergoing CABG--the MoMIC trial.
  • 2009
  • Ingår i: Scandinavian cardiovascular journal. - : Informa UK Limited. - 1651-2006 .- 1401-7431. ; 43:1, s. 50-6
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: The presence of mild to moderate ischemic mitral regurgitation (IMR) marks a significantly reduced long-term survival and increased hospitalizations due to heart-failure. However, it is common practice in many institutions to refrain from repairing the mitral valve in these patients. There are no available conclusive data to support this practice, and thus there is a need for an adequately powered randomized trial. STUDY DESIGN: The Moderate Mitral Regurgitation In Patients Undergoing CABG (MoMIC) trial is the first international multi-center, large-scale study to clarify whether moderate IMR in CABG patients should be corrected. A total of 550 CABG patients with moderate IMR are to be randomized to treatment of either CABG alone or CABG plus mitral valve correction. The primary end point is a composite end point of mortality and rehospitalization for heart failure at five years. The inclusion and randomization of patients started in February 2008. IMPLICATION: If correction of moderate IMR in CABG patients proves to be the superior strategy, most patients should be treated accordingly.
  •  
2.
  • Wierup, Per, et al. (författare)
  • The prevalence of moderate mitral regurgitation in patients undergoing CABG.
  • 2009
  • Ingår i: Scandinavian cardiovascular journal : SCJ. - : Informa UK Limited. - 1651-2006 .- 1401-7431. ; 43:1, s. 46-9
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: The aim of this study was to determine the prevalence of moderate ischemic mitral regurgitation (IMR) in the contemporary CABG population. We also aimed to correlate the effective regurgitant orifice area (ERO) of any regurgitant mitral valve in patients with coronary artery disease with the semiquantitative integrated scale of IMR. DESIGN: From March 15 through June 15, 2006, 510 consecutive CABG patients in three tertiary centres were included in the study. All patients showing any sign of mitral regurgitation (MR) at the referring hospital underwent a preoperative transthoracic echocardiographic estimation of the degree of MR using the integrated scale (1-4) and ERO. RESULTS: IMR was found in 141 patients (28%). The prevalence of moderate 2+ or worse IMR was 4% (95% CI; 2.5-6.1%) and the ERO corresponding to 2+ IMR or more ranged from 5 to 30 mm(2). Fourteen patients had an ERO between 15-30 mm(2). CONCLUSIONS: According to our study, patients with moderate IMR, defined as an ERO between 15-30 mm(2), account for only 2.7% (95% CI; 1.5-4.7%) of a non-emergency CABG population.
  •  
3.
  • Aljassim, Obaid, et al. (författare)
  • Doppler-catheter discrepancies in patients with bileaflet mechanical prostheses or bioprostheses in the aortic valve position.
  • 2008
  • Ingår i: The American journal of cardiology. - : Elsevier BV. - 1879-1913 .- 0002-9149. ; 102:10, s. 1383-9
  • Tidskriftsartikel (refereegranskat)abstract
    • The aims of the present study were to investigate in vivo Doppler-catheter discrepancies in aortic bileaflet mechanical and stented biologic valves and evaluate whether these can be predicted using Doppler echocardiography. Results of in vitro studies of bileaflet mechanical valves suggested overestimation using Doppler gradients. Findings in stented biologic valves were conflicting. Patients who underwent valve replacement with a St. Jude Medical mechanical (n = 14, size 19 to 29) or a St. Jude Medical Biocor (Biocor, n = 13, size 21 to 25) valve were included. Simultaneous continuous Doppler recordings (transesophageal transducer) and left ventricular and aortic pressure measurements were performed using high-fidelity catheters. Gradients after pressure recovery were predicted from Doppler using a validated equation. Doppler overestimated catheter gradients in both the mechanical and Biocor. Mean Doppler catheter differences for the mechanical/Biocor were for mean gradients of 4 +/- 3 (SD; p = 0.002)/6 +/- 4 mm Hg (p = 0.002). There was a strong relation between catheter and Doppler gradients (r = 0.85 to 0.92). Doppler catheter discrepancy as a percentage of the Doppler mean gradient for the mechanical was median 41% (range -30% to 76%) and for the Biocor was median 35% (range -7% to 75%). The catheter-Doppler discrepancy was not significant using the predicted net gradient from Doppler. In conclusion, this was the first in vivo investigation of prosthetic valves using simultaneous Doppler and high-fidelity catheters. Doppler overestimated catheter gradients in both mechanical and stented biologic valves. However, the discrepancy can be predicted considering pressure recovery in the aorta.
  •  
4.
  • Bech-Hanssen, Odd, 1956, et al. (författare)
  • Doppler echocardiography can provide a comprehensive assessment of right ventricular afterload
  • 2009
  • Ingår i: Journal of the American Society of Echocardiography. - : Elsevier BV. - 0894-7317. ; 22:12, s. 1360-7
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: The purpose of this study was to evaluate novel Doppler echocardiographic methods for a comprehensive assessment of right ventricular afterload, including pulmonary artery (PA) mean pressure (PAMP) and the PA pressure waveform. METHODS: The study comprised 109 patients who underwent right-heart catheterization simultaneously (group A, n = 31) with Doppler echocardiography on 35 occasions or nonsimultaneously (group B, n = 78) within 24 hours of Doppler echocardiography. Right ventricular afterload variables were obtained using pulsed Doppler in the PA and continuous Doppler of tricuspid regurgitation. The intervals from QRS to the opening and closing of the pulmonary valve and to the peak velocity of tricuspid regurgitation were measured. PA end-diastolic pressure, PA systolic pressure, and PA notch pressure were calculated. The Doppler-derived pressure curve was separated into 3 parts with fitted second-order curves. RESULTS: Catheter PAMP and Doppler PA systolic pressure in group A were strongly related (R = 0.85). The regression equation from group A (PAMP = 0.65 x Doppler PA systolic pressure - 1.2 mm Hg) was used to calculate PAMP in group B. There was no difference between catheter PAMP (mean, 39 +/- 18 mm Hg; range, 8-95 mm Hg) and Doppler PAMP (mean, 39 +/- 15 mm Hg; range, 12-83 mm Hg) (P = .85). The systolic areas under the curves for catheter and Doppler PAMP in group A were 20 +/- 4.7 and 20 +/- 4.0 mm Hg s, respectively (P = .52), and the diastolic areas were 21 +/- 5.7 and 22 +/- 6.3 mm Hg s, respectively (P = .21). CONCLUSION: A comprehensive assessment of right ventricular afterload that includes PAMP and the PA pressure waveform can be provided by Doppler echocardiography in patients with a wide range of PA pressures and different diagnoses.
  •  
5.
  • Gjertsson, Peter, 1961, et al. (författare)
  • Diagnostic and referral delay in patients with aortic stenosis is common and negatively affects outcome
  • 2007
  • Ingår i: Scand Cardiovasc J. - : Informa UK Limited. - 1401-7431 .- 1651-2006. ; 41:1, s. 12-8
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: Aortic stenosis (AS) patients are often severely symptomatic at the time of aortic valve replacement (AVR). We wanted to investigate doctors' delay and its impact on outcome. DESIGN: AS patients undergoing AVR (n = 422) were included. Clinical and echocardiographic data at the time of diagnosis and preoperatively were noted. The risk of death after AVR was estimated using Poisson regression, incorporating age, gender, coronary artery disease, NYHA III/IV and time on the waiting list for AVR. RESULTS: The age (mean+/-SD) was 71+/-8.6 years, 45% were women, and 48% were in NYHA III/IV. 55% underwent AVR within one year of diagnosis, indicating late diagnosis. The time from referral to AVR (median, range) was 112 (1-803) days. NYHA III/IV independently predicted mortality (hazard ratio 1.76, 95% CI 1.28-2.43, p = 0.0005). The time from referral to AVR influenced the risk of death immediately after operation (p = 0.0083). CONCLUSION: Late diagnosis and late referral for AVR are common, and negatively influence outcome in patients with AS. Delay in surgery after referral increase the mortality immediately after AVR.
  •  
6.
  • Gjertsson, Peter, 1961, et al. (författare)
  • Left ventricular diastolic dysfunction late after aortic valve replacement in patients with aortic stenosis
  • 2005
  • Ingår i: Am J Cardiol. - : Elsevier BV. - 0002-9149. ; 96:5, s. 722-7
  • Tidskriftsartikel (refereegranskat)abstract
    • Patients with severe aortic stenosis (AS) are known to have increased left ventricular (LV) mass and diastolic dysfunction. It has been suggested that LV mass and diastolic function normalize after aortic valve replacement (AVR). In the present study, change in LV mass index and diastolic function 10 years after AVR for AS was evaluated. Patients who underwent AVR from 1991 to 1993 (n = 57; mean age 67 +/- 8.6 years at AVR, 58% men) were investigated with Doppler echocardiography preoperatively and 2 and 10 years postoperatively. Diastolic function was evaluated by integrating mitral and pulmonary venous flow data. Expected values for each patient, taking age into consideration, were defined using a control group (n = 71; age range 18 to 83 years). Patients were classified into 4 types: normal diastolic function (type A), mild diastolic dysfunction (type B), moderate diastolic dysfunction (type C), and severe diastolic dysfunction (type D). There was a reduction in LV mass index between the preoperative (161 +/- 39 g/m2) and 2-year follow-up (114 +/- 28 g/m2) examinations (p <0.0001), but no further reduction was seen at 10 years (119 +/- 49 g/m2). The percentage of patients with increased LV mass index decreased from 83% preoperatively to 29% at 2-year follow-up (p <0.001). The percentage of patients with moderate to severe LV diastolic dysfunction (types C and D) was unchanged between the preoperative (7%) and 2-year follow-up (13%) examinations (p = 0.27). The percentage of patients increased at 10-year follow-up to 61% (p <0.0001). In conclusion, this reveals the development of moderate to severe diastolic dysfunction 10 years after AVR, despite a reduction in the LV mass index.
  •  
7.
  • Gjertsson, Peter, 1961, et al. (författare)
  • Preoperative moderate to severe diastolic dysfunction: a novel Doppler echocardiographic long-term prognostic factor in patients with severe aortic stenosis
  • 2005
  • Ingår i: J Thorac Cardiovasc Surg. - : Elsevier BV. - 0022-5223. ; 129:4, s. 890-6
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: We studied long-term outcomes in severe aortic stenosis and the importance of prosthesis type (mechanical vs biologic) and size, preoperative left ventricular ejection fraction, diastolic function, and left ventricular mass. METHODS: Patients undergoing valve replacement from 1991 to 1993 (n = 399, 45% women) were included. The diastolic function was evaluated by integrating mitral and pulmonary venous flow data with Doppler echocardiography. The patients were classified as having either normal diastolic function to mild diastolic dysfunction or moderate to severe diastolic dysfunction. Left ventricular ejection fraction and the diastolic function category were incorporated together with age, sex, and time since operation into a Poisson regression model with death as the end point. Prosthesis type and size and left ventricular mass were also investigated. RESULTS: The age (mean +/- SD) was 71 +/- 9 years, and the overall survival after 12 years was 50%. Although markedly reduced during the initial 6-month period, mortality risk subsequently increased more than could be explained by age (hazard ratio of 1-year difference = 1.12, P = .0005). The moderate to severe diastolic dysfunction pattern independently predicted late mortality (hazard ratio = 1.72, P = .0038), whereas left ventricular ejection fraction did not (hazard ratio = 0.99, P = .18). The prognostic importance of moderate to severe diastolic dysfunction did not diminish with time; on the contrary, it tended to increase. Mortality after 12 years was not predicted by left ventricular mass (P = .66), prosthesis type (P = .57), or prosthesis size (P = .58). CONCLUSION: This study reveals that moderate to severe diastolic dysfunction in patients with aortic stenosis is an independent predictor of late mortality after valve replacement and that its importance does not decrease with time. Our findings may suggest that moderate to severe diastolic dysfunction implies nonreversible myocardial changes that negatively affect survival.
  •  
8.
  • Guron, Cecilia Wallentin, 1965, et al. (författare)
  • The E/e filling index and right ventricular pressure in relation to applied international Doppler recommendations of left ventricular filling assessment
  • 2005
  • Ingår i: Eur J Echocardiogr. - : Oxford University Press (OUP). - 1525-2167. ; 6:6, s. 419-28
  • Tidskriftsartikel (refereegranskat)abstract
    • AIM: A ratio>15 between the early diastolic pulsed Doppler velocities of the mitral inflow (E) and the basal left ventricular (LV) tissue (e) has been demonstrated to predict an elevated LV filling pressure (FP). An elevated LVFP implies an elevated right ventricular pressure (RVp). In order to investigate the sensitivity of the E/e filling index, we compared E/e and RVp, in their ability to identify a Doppler-assumed elevation of LVFP. METHODS AND RESULTS: Application of pulsed Doppler international recommendations grouped 134 patients with acute coronary syndromes (ACS) and 50 age- and sex-matched controls, according to LV filling: normal; delayed relaxation; an isolated pathological mitral-pulmonary venous-A-wave-duration difference; pseudo normal; or a restrictive filling pattern. An E/e>15 and an RVp>30 mmHg showed the following (%) sensitivity (32/94), specificity (95/76), positive (68/59), and negative (80/97) predictive values of a Doppler-assumed elevation of LVFP, in terms of either a pseudo normal or a restrictive filling pattern. CONCLUSION: The low sensitivity of E/e to detect a Doppler-assumed elevation of LVFP could limit its clinical usefulness as a single variable, in ACS. The high sensitivity and negative predictive value of RVp support its use as an additional LV filling variable in these patients.
  •  
9.
  • Hadimeri, Henrik, 1962, et al. (författare)
  • Echocardiographic findings in kidney transplant patients with autosomal dominant polycystic kidney disease
  • 2009
  • Ingår i: Scand J Urol Nephrol. ; 43:5, s. 416-9
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: Autosomal dominant polycystic kidney disease (ADPKD) is a systemic disorder with a tendency for aneurysm formation which may also affect the heart. ADPKD kidney transplant patients were studied by echocardiography. MATERIAL AND METHODS: The case-control study consisted of 21 kidney transplant recipients and a group of 21 transplant patients with other diagnoses. They were in a stable phase a median of 3 years (range 1-10) after transplantation. M-mode and two-dimensional echocardiography were performed. RESULTS: Age, haemoglobin and renal function were not different between the groups but ADPKD patients had significantly lower systolic blood pressure (p=0.004). There were no abnormalities in the aortic or mitral valve in either group. The diameter of the left ventricular outflow tract, the bulb or the ascending aorta did not differ between the groups. The diameters of the left ventricle or atrium were also similar. The left ventricular mass index was 132+/-36 in ADPKD patients versus 163+/-63 g/m(2) in the controls (p=0.11). The left ventricular ejection fraction was 69+/-9.0 versus 70+/-8.9%. Early and atrial filling waves were equal. CONCLUSION: Valvular anomalies were infrequent. Aneurysm formation in the aorta and signs of dilated cardiomyopathy were not increased in patients with ADPKD.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 16
Typ av publikation
tidskriftsartikel (16)
Typ av innehåll
refereegranskat (16)
Författare/redaktör
Bech-Hanssen, Odd, 1 ... (16)
Caidahl, Kenneth, 19 ... (5)
Gjertsson, Peter, 19 ... (3)
Selimovic, Nedim, 19 ... (2)
Kimblad, Per Ola (2)
Roijer, Anders (2)
visa fler...
Wierup, Per (2)
Houltz, Erik, 1951 (2)
Rundqvist, Bengt, 19 ... (2)
Scherstén, Henrik, 1 ... (2)
Nilsson, Folke, 1950 (2)
Poulsen, Steen Hvitf ... (2)
Egeblad, Henrik (2)
Nielsen, Sten Lyager (2)
Snygg, Johan, 1963 (1)
Oden, A (1)
Rosengren, Annika, 1 ... (1)
Lönn, L (1)
Hadimeri, Henrik, 19 ... (1)
Odén, Anders, 1942 (1)
Nyberg, Gudrun, 1942 (1)
Aljassim, Obaid (1)
Svensson, Gunnar, 19 ... (1)
Guron, Cecilia Walle ... (1)
Andersson, Bert, 195 ... (1)
Wikh, R (1)
Andersson, Bertil (1)
Mobini, Reza, 1965 (1)
Rundqvist, B. (1)
Ricksten, Sven-Erik, ... (1)
Wallentin, Jonas, 19 ... (1)
Bergh, Claes-Håkan, ... (1)
Hartford, Marianne, ... (1)
Johansson, Lena (1)
Johnsen, Søren Paask ... (1)
Ljungman, Susanne, 1 ... (1)
Åneman, Anders, 1965 (1)
Carlson, Jan, 1955 (1)
Skoogh, Bengt-Eric, ... (1)
Jörgensen, Kirsten, ... (1)
Farasati, M. (1)
Hemlin, Mats, 1959 (1)
Maljukanovic, S (1)
Selimovic, N. (1)
Sadik, May, 1970 (1)
Petersson, Sofia (1)
Mykén, Pia, 1951 (1)
Nordblom, P. (1)
Nielsen, Per Hostrup (1)
McCarthy, Patrick M (1)
visa färre...
Lärosäte
Göteborgs universitet (16)
Karolinska Institutet (4)
Lunds universitet (2)
Chalmers tekniska högskola (2)
Språk
Engelska (16)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (7)
Lantbruksvetenskap (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy