SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Berggren Karl) srt2:(2020-2024)"

Sökning: WFRF:(Berggren Karl) > (2020-2024)

  • Resultat 1-10 av 17
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Ahmed, Fareed, et al. (författare)
  • Manufacturing Poly(3,4-Ethylenedioxythiophene) Electrocatalytic Sheets for Large-Scale H2O2 Production
  • 2022
  • Ingår i: Advanced Sustainable Systems. - : John Wiley and Sons Inc. - 2366-7486. ; 6:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Producing thick films of conducting polymers by a low-cost manufacturing technique would enable new applications. However, removing huge solvent volume from diluted suspension or dispersion (1–3 wt%) in which conducting polymers are typically obtained is a true manufacturing challenge. In this work, a procedure is proposed to quickly remove water from the conducting polymer poly(3,4-ethylenedioxythiophene:poly(4-styrene sulfonate) (PEDOT:PSS) suspension. The PEDOT:PSS suspension is first flocculated with 1 m H2SO4 transforming PEDOT nanoparticles (≈50–500 nm) into soft microparticles. A filtration process inspired by pulp dewatering in a paper machine on a wire mesh with apertures dimension between 60 µm and 0.5 mm leads to thick free-standing films (≈0.5 mm). Wire mesh clogging that hinders dewatering (known as dead-end filtration) is overcome by adding to the flocculated PEDOT:PSS dispersion carbon fibers that aggregate and form efficient water channels. Moreover, this enables fast formation of thick layers under simple atmospheric pressure filtration, thus making the process truly scalable. Thick freestanding PEDOT films thus obtained are used as electrocatalysts for efficient reduction of oxygen to hydrogen peroxide, a promising green chemical and fuel. The inhomogeneity of the films does not affect their electrochemical function. © 2021 The Authors. 
  •  
2.
  • Andersson, Malte, 1941, et al. (författare)
  • ”Minskande befolkning är inte problemet”
  • 2020
  • Ingår i: Dagens Nyheter. ; :1 augusti, DN-debatt
  • Tidskriftsartikel (populärvet., debatt m.m.)abstract
    • Nätverket Population Matters Sweden: En uppmärksammad studie i The Lancet pekar mot en lägre befolkningsökning i världen än tidigare prognoser. Men en miljard människor till är fortfarande långt över vad jorden klarar. Befolkningstrenden måste snarare vända neråt, och det kräver åtgärder för att stärka kvinnors rättigheter världen över.
  •  
3.
  • Belaineh Yilma, Dagmawi, et al. (författare)
  • Printable carbon-based supercapacitors reinforced with cellulose and conductive polymers
  • 2022
  • Ingår i: Journal of Energy Storage. - : Elsevier Ltd. - 2352-152X .- 2352-1538. ; 50
  • Tidskriftsartikel (refereegranskat)abstract
    • Sustainable electrical energy storage is one of the most important scientific endeavors of this century. Battery and supercapacitor technologies are here crucial, but typically the current state of the art suffers from either lack of large-scale production possibilities, sustainability or insufficient performance and hence cannot match growing demands in society. Paper and cellulosic materials are mature scalable templates for industrial roll-to-roll production. Organic materials, such as conducting polymers, and carbon derivatives are materials that can be synthesized or derived from abundant sources. Here, we report the combination of cellulose, PEDOT:PSS and carbon derivatives for bulk supercapacitor electrodes adapted for printed electronics. Cellulose provides a mesoscopic mesh for the organization of the active ingredients. Furthermore, the PEDOT:PSS in combination with carbon provides superior device characteristics when comparing to the previously standard combination of activated carbon and carbon black. PEDOT:PSS acts as a mixed ion-electron conducting glue, which physically binds activated carbon particles together, while at the same time facilitating swift transport of both electrons and ions. A surprisingly small amount (10%) of PEDOT:PSS is needed to achieve an optimal performance. This work shows that cellulose added to PEDOT:PSS-carbon enables high-performing, mechanically stable, printed supercapacitor electrodes using a combination of printing methods.
  •  
4.
  • Berggren, Johanna, et al. (författare)
  • Reperfusion of Free Full-Thickness Skin Grafts in Periocular Reconstructive Surgery Monitored Using Laser Speckle Contrast Imaging
  • 2021
  • Ingår i: Ophthalmic Plastic and Reconstructive Surgery. - 1537-2677. ; 37:4, s. 324-328
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: Free skin grafts are frequently used in reconstructive surgery. However, little is known about the course of reperfusion due to the previous lack of reliable perfusion monitoring techniques. The aim of this study was to use state-of-the-art laser speckle contrast imaging to monitor free skin grafts in the periocular area.METHODS: Seven patients needing surgery due to tumor removal or cicatricial ectropion in the periocular region underwent reconstructive surgery using free skin grafts from either the contralateral upper eyelid or the upper inner arm. The free skin grafts measured 10-30 mm horizontally and 9-30 mm vertically. Blood perfusion was monitored using laser speckle contrast imaging immediately postoperatively (0 weeks) and at follow-up after 1, 3, and 7 weeks.RESULTS: All grafts were reperfused gradually during healing, the median value being 46% in the central part of the graft after 1 week and 79% after 3 weeks. The grafts were completely reperfused after 7 weeks. No difference was observed in the rate of reperfusion between the center and periphery of the grafts (p = not significant). The cosmetic and functional outcome was excellent in all but 1 patient, who developed ectropion that had to be surgically corrected.CONCLUSIONS: Skin grafts in the periorbital area are fully reperfused after 7 weeks. The periocular area is known to be well-vascularized and thus forgiving to reconstructive surgery. Future investigations of the reperfusion of free skin grafts in other parts of the body or in higher-risk populations should be carried out.
  •  
5.
  • Berggren, Johanna, et al. (författare)
  • Revascularization After H-plasty Reconstructive Surgery in the Periorbital Region Monitored With Laser Speckle Contrast Imaging
  • 2021
  • Ingår i: Ophthalmic Plastic and Reconstructive Surgery. - 1537-2677. ; 37:3, s. 269-273
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: H-plasty reconstructive surgery is commonly used to close defects after tumor excision in the periorbital region. Revascularization of the bipedicle skin flaps is essential for healing. However, it has not previously been possible to study this revascularization in humans due to the lack of noninvasive perfusion monitoring techniques. The aim was to monitor perfusion in H-plasty flaps during surgery and during postoperative follow-up, using laser speckle contrast imaging.METHOD: H-plasty, i.e., bipedicle random advancement skin flaps, was used for reconstruction of the eyelids after tumor removal in 7 patients. The median length and width of the skin flaps were 13 mm (range, 8-20 mm) and 10 mm (range, 5-11 mm), respectively. Blood perfusion was measured using laser speckle contrast imaging during surgery and at follow up 1, 3, and 6 weeks postoperatively, to monitor revascularization.RESULTS: Immediately postoperatively, the perfusion in the distal end of the flaps had fallen to 54% (95% CI, 38%-67%). The perfusion then quickly increased during the healing process, being 104% (86%-124%) after 1 week, 115% (94%-129%) after 3 weeks, and 112% (96%-137%) after 6 weeks. There was no clinically observable ischemia or tissue necrosis.CONCLUSIONS: Revascularization of the H-plasty procedure flaps occurs quickly, within a week postoperatively, presumably due to the existing vascular network of the flap pedicle, and was not dependent on significant angiogenesis. This perfusion study confirms the general opinion that H-plasty is a good reconstructive technique, especially in the periorbital region with its rich vascular supply.
  •  
6.
  • Berggren, Johanna V, et al. (författare)
  • Laser Speckle Contrast Imaging of a Rotational Full-Thickness Lower Eyelid Flap Shows Satisfactory Blood Perfusion
  • 2021
  • Ingår i: Ophthalmic Plastic and Reconstructive Surgery. - 1537-2677. ; 37:4, s. 139-141
  • Tidskriftsartikel (refereegranskat)abstract
    • Full-thickness eyelid flaps from the lower eyelid are frequently used to repair larger upper eyelid defects. Perfusion monitoring has recently been implemented in several reconstructive surgical procedures, however, perfusion monitoring of a rotational eyelid flap has not yet been described. The authors' employed laser speckle contrast imaging to monitor blood perfusion in a rotational flap from the lower eyelid, used to cover a large tumor defect in the upper eyelid. Perfusion in the flap decreased by only 50% during surgery and was almost completely restored 5 weeks later at flap division (91%). The excellent surgical outcome in the present case is deemed to be the result of satisfactory blood perfusion of the flap.
  •  
7.
  • Berggren, Johanna V, et al. (författare)
  • Laser Speckle Contrast Imaging of the Blood Perfusion in Glabellar Flaps Used to Repair Medial Canthal Defects
  • 2022
  • Ingår i: Ophthalmic Plastic and Reconstructive Surgery. - 1537-2677. ; 38:3, s. 274-279
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: The glabellar flap is a common technique for surgical repair after tumor excision in the medial canthal area. However, the outcome may be affected by partial flap necrosis. Little is known about the impact of surgery on blood perfusion and the postoperative course of reperfusion due to the absence of reliable and noninvasive perfusion monitoring techniques. The aim of this study was to use a modern imaging technique to assess blood perfusion in glabellar flaps.METHODS: Glabellar flaps were used to repair medial canthal defects following tumor excision in 7 patients. Blood perfusion was monitored using laser speckle contrast imaging: during surgery, immediately postoperatively (0 weeks), and at follow-up, 1, 3, and 6 weeks after surgery.RESULTS: Perfusion decreased gradually along the length of the flap, and reached a minimum 15 mm from the flap base. Perfusion in the proximal 20 mm of the flap was completely restored after 1 week, while the distal part of the flap was gradually reperfused over 6 weeks. Both the functional and esthetic surgical outcomes were excellent.CONCLUSIONS: The rapid reperfusion of the glabellar flap may be explained by its connection to the vascular network via the flap pedicle. In flaps longer than 20 mm, the distal part can be considered a free skin transplant, and a combination of a glabellar flap and a free skin graft could then be considered.
  •  
8.
  • Bohman, Elin, et al. (författare)
  • Novel Evidence Concerning Lacrimal Sac Movement Using Ultra-High-Frequency Ultrasound Examinations of Lacrimal Drainage Systems
  • 2021
  • Ingår i: Ophthalmic Plastic and Reconstructive Surgery. - 1537-2677. ; 37:4, s. 334-340
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: Current hypothesis regarding the mechanism of active tear drainage is based on studies performed ex vivo or under nonphysiological conditions. Novel ultra-high-frequency ultrasound has the advantage of generating images with superior resolution, enabling measurements of low flow in small vessels, and the tracking of tissue motion in real time. The purpose of this study was to investigate the lacrimal drainage system and active drainage using this modality.METHODS: The upper lacrimal drainage system was investigated with 40-70 MHz ultrasound in 22 eyes in 13 patients. Irrigation confirmed a lacrimal obstruction in 10 eyes. Motion tracking was used to map movement of the lateral lacrimal sac wall and to measure flow when possible.RESULTS: The anatomy of the upper lacrimal drainage system was mapped in vivo, including the proximal canaliculi, which have not previously been imaged. The lacrimal sac lumen is slit shaped in its resting state but is distended when irrigated or if a nasolacrimal duct obstruction is present. Thus, the healthy lacrimal sac is not a cavity, and the medial retinaculum does not act against a stretched structure. Motion tracking visualized the "lacrimal pump," showing that the direction of motion of the lateral lacrimal sac wall is mainly in the sagittal plane during blinking.CONCLUSIONS: Ultra-high-frequency ultrasound allows detailed physiological monitoring of the upper lacrimal drainage system in vivo. Our findings suggest that current theories of active tear drainage need to be reappraised.
  •  
9.
  • Brooke, Robert, 1989-, et al. (författare)
  • Nanocellulose and PEDOT:PSS composites and their applications
  • 2023
  • Ingår i: Polymer Reviews. - : Taylor and Francis Ltd.. - 1558-3724 .- 1558-3716. ; :2, s. 437-
  • Tidskriftsartikel (refereegranskat)abstract
    • The need for achieving sustainable technologies has encouraged research on renewable and biodegradable materials for novel products that are clean, green, and environmentally friendly. Nanocellulose (NC) has many attractive properties such as high mechanical strength and flexibility, large specific surface area, in addition to possessing good wet stability and resistance to tough chemical environments. NC has also been shown to easily integrate with other materials to form composites. By combining it with conductive and electroactive materials, many of the advantageous properties of NC can be transferred to the resulting composites. Conductive polymers, in particular poly(3,4-ethylenedioxythiophene:poly(styrene sulfonate) (PEDOT:PSS), have been successfully combined with cellulose derivatives where suspensions of NC particles and colloids of PEDOT:PSS are made to interact at a molecular level. Alternatively, different polymerization techniques have been used to coat the cellulose fibrils. When processed in liquid form, the resulting mixture can be used as a conductive ink. This review outlines the preparation of NC/PEDOT:PSS composites and their fabrication in the form of electronic nanopapers, filaments, and conductive aerogels. We also discuss the molecular interaction between NC and PEDOT:PSS and the factors that affect the bonding properties. Finally, we address their potential applications in energy storage and harvesting, sensors, actuators, and bioelectronics. © 2022 The Author(s). 
  •  
10.
  • Charaev, Ilya, et al. (författare)
  • Single-photon detection using large-scale high-temperature MgB 2 sensors at 20 K
  • 2024
  • Ingår i: Nature Communications. - 2041-1723 .- 2041-1723. ; 15:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Ultra-fast single-photon detectors with high current density and operating temperature can benefit space and ground applications, including quantum optical communication systems, lightweight cryogenics for space crafts, and medical use. Here we demonstrate magnesium diboride (MgB2) thin-film superconducting microwires capable of single-photon detection at 1.55 μm optical wavelength. We used helium ions to alter the properties of MgB2, resulting in microwire-based detectors exhibiting single-photon sensitivity across a broad temperature range of up to 20 K, and detection efficiency saturation for 1 μm wide microwires at 3.7 K. Linearity of detection rate vs incident power was preserved up to at least 100 Mcps. Despite the large active area of up to 400 × 400 μm2, the reset time was found to be as low as ~ 1 ns. Our research provides possibilities for breaking the operating temperature limit and maximum single-pixel count rate, expanding the detector area, and raises inquiries about the fundamental mechanisms of single-photon detection in high-critical-temperature superconductors.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 17
Typ av publikation
tidskriftsartikel (16)
doktorsavhandling (1)
Typ av innehåll
refereegranskat (15)
övrigt vetenskapligt/konstnärligt (1)
populärvet., debatt m.m. (1)
Författare/redaktör
Malmsjö, Malin (6)
Hult, Jenny (4)
Håkansson, Karl (3)
Albinsson, John (3)
Berggren, Magnus (2)
Moruzzi, Noah (2)
visa fler...
Berggren, Per-Olof (2)
Cinthio, Magnus (2)
Grinnemo, Karl-Henri ... (2)
Wågberg, Lars, 1956- (2)
Brooke, Robert, 1989 ... (2)
Yu, Yang (1)
Götmark, Frank, 1955 (1)
Cherednichenko, Serg ... (1)
Engquist, Isak (1)
Wang, Xin (1)
Granberg, Hjalmar (1)
Fall, Andreas (1)
Berggren, Magnus, Pr ... (1)
Vagin, Mikhail, 1976 ... (1)
Lara Avila, Samuel, ... (1)
Wallin, Mats (1)
Zubarev, Roman A (1)
Berggren, Karl (1)
Holmdahl, Rikard (1)
Ahmed, Fareed (1)
Ding, Penghui (1)
Ail, Ujwala, 1980- (1)
Warczak, Magdalena (1)
Grimoldi, Andrea, 19 ... (1)
Ederth, Thomas, 1969 ... (1)
Gueskine, Viktor (1)
Berggren, Magnus, 19 ... (1)
Crispin, Xavier, Pro ... (1)
Hasegawa, Hideyuki (1)
Holm, Stig-Olof (1)
Micke, Patrick (1)
Alici, Evren (1)
Berggren, Christian (1)
Boldemann, Cecilia (1)
Simonson, Oscar (1)
Millischer, Vincent (1)
Zhang, Bin (1)
Drakinskiy, Vladimir ... (1)
Lidmar, Jack, 1968- (1)
Pekar-Lukacs, Agnes (1)
Merdasa, Aboma (1)
Andersson, Malte, 19 ... (1)
Deinum, Johanna (1)
Wijkman, Anders (1)
visa färre...
Lärosäte
Lunds universitet (7)
Karolinska Institutet (5)
Kungliga Tekniska Högskolan (4)
Linköpings universitet (4)
RISE (4)
Göteborgs universitet (1)
visa fler...
Uppsala universitet (1)
Högskolan i Skövde (1)
Chalmers tekniska högskola (1)
visa färre...
Språk
Engelska (17)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (10)
Naturvetenskap (7)
Teknik (4)
Samhällsvetenskap (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy