SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Bevilacqua F)
 

Sökning: WFRF:(Bevilacqua F) > (2000-2004) > Quantifying the abs...

Quantifying the absorption and reduced scattering coefficients of tissuelike turbid media over a broad spectral range with noncontact Fourier-transform hyperspectral imaging

Pham, T. H (författare)
Bevilacqua, F (författare)
Spott, T (författare)
visa fler...
Dam, J. S (författare)
Tromberg, B. J (författare)
Andersson-Engels, Stefan (författare)
Lund University,Lunds universitet,Atomfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Atomic Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
visa färre...
 (creator_code:org_t)
2000
2000
Engelska.
Ingår i: Applied Optics. - 2155-3165. ; 39:34, s. 6487-6497
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Absorption (mu (a)) and reduced scattering (mu (s)') spectra of turbid media were quanti fied with a noncontact imaging approach based on a Fourier-transform interferometric imaging system (FTIIS). The FTIIS was used to collect hyperspectral images of the steady-state diffuse reflectance from turbid media. Spatially resolved reflectance data from Monte Carlo simulations were fitted to the recorded hyperspectral images to quantify mu (a) and mu (s)' spectra in the 550-850-nm region. A simple and effective calibration approach was introduced to account for the instrument response. With reflectance data that were close to and far from the source (0.5-6.5 mm), mu (a) and mu (')(s) of homogeneous, semi-infinite turbid phantoms with optical property ranges comparable with those of tissues were determined with an accuracy of +/-7% and +/-3%, respectively. Prediction accuracy for mu (a) and mu (s)' degraded to +/-12% and +/-4%, respectively, when only reflectance data close to the source (0.5-2.5 mm) were used. Results indicate that reflectance data close to and far hom the source are necessary for optimal quantification of mu (a) and mu (s)'. The spectral properties of mu (a) and mu (s)' values were used to determine the concentrations of absorbers and scatterers, respectively. Absorber and scatterer concentrations of two-chromophore turbid media were determined with an accuracy of +/-5% and +/-3%, respectively. (C) 2000 Optical Society of America OCIS codes: 170.0110, 170.7050, 170.6510, 070.2590, 120.3180.

Ämnesord

NATURVETENSKAP  -- Fysik -- Atom- och molekylfysik och optik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Atom and Molecular Physics and Optics (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Pham, T. H
Bevilacqua, F
Spott, T
Dam, J. S
Tromberg, B. J
Andersson-Engels ...
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Fysik
och Atom och molekyl ...
Artiklar i publikationen
Applied Optics
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy