SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Birch M.) srt2:(2020-2024)"

Sökning: WFRF:(Birch M.) > (2020-2024)

  • Resultat 1-10 av 21
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Niemi, MEK, et al. (författare)
  • 2021
  • swepub:Mat__t
  •  
2.
  • Kanai, M, et al. (författare)
  • 2023
  • swepub:Mat__t
  •  
3.
  • Aalbers, J., et al. (författare)
  • A next-generation liquid xenon observatory for dark matter and neutrino physics
  • 2023
  • Ingår i: Journal of Physics G: Nuclear and Particle Physics. - : IOP Publishing. - 0954-3899 .- 1361-6471. ; 50:1
  • Forskningsöversikt (refereegranskat)abstract
    • The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for weakly interacting massive particles, while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neutrinos through neutrinoless double-beta decay and through a variety of astrophysical sources. A next-generation xenon-based detector will therefore be a true multi-purpose observatory to significantly advance particle physics, nuclear physics, astrophysics, solar physics, and cosmology. This review article presents the science cases for such a detector.
  •  
4.
  • Patterson, Brooke E., et al. (författare)
  • Evaluation of an injury prevention programme (Prep-to-Play) in women and girls playing Australian Football : design of a pragmatic, type III, hybrid implementation-effectiveness, stepped-wedge, cluster randomised controlled trial
  • 2022
  • Ingår i: BMJ Open. - : BMJ Publishing Group. - 2044-6055. ; 12:9
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction Due to the increase in participation and risk of anterior cruciate ligament (ACL) injuries and concussion in womens Australian Football, an injury prevention programme (Prep-to-Play) was codesigned with consumers (eg, coaches, players) and stakeholders (eg, the Australian Football League). The impact of supported and unsupported interventions on the use of Prep-to-Play (primary aim) and injury rates (secondary aim) will be evaluated in women and girls playing community Australian Football. Methods and analysis This stepped-wedge, cluster randomised controlled trial will include >= 140 teams from U16, U18 or senior womens competitions. All 10 geographically separated clusters (each containing >= 14 teams) will start in the control (unsupported) phase and be randomised to one of five dates (or wedges) during the 2021 or 2022 season to sequentially transition to the intervention (supported Prep-to-Play), until all teams receive the intervention. Prep-to-Play includes four elements: a neuromuscular training warm-up, contact-focussed football skills (eg, tackling), strength exercises and education (eg, technique cues). When transitioning to supported interventions, study physiotherapists will deliver a workshop to coaches and player leaders on how to use Prep-to-Play, attend team training at least two times and provide ongoing support. In the unsupported phase, team will continue usual routines and may freely access available Prep-to-Play resources online (eg, posters and videos about the four elements), but without additional face-to-face support. Outcomes will be evaluated throughout the 2021 and 2022 seasons (similar to 14 weeks per season). Primary outcome: use of Prep-to-Play will be reported via a team designate (weekly) and an independent observer (five visits over the two seasons) and defined as the team completing 75% of the programme, two-thirds (67%) of the time. Secondary outcomes: injuries will be reported by the team sports trainer and/or players. Injury definition: any injury occurring during a football match or training that results in: (1) being unable to return to the field of play for that match or (2) missing >= one match. Outcomes in the supported and unsupported phases will be compared using a generalised linear mixed model adjusting for clustering and time. Due to the type III hybrid implementation-effectiveness design, the study is powered to detect a improvement in use of Prep-to-Play and a reduction in ACL injuries. Ethics and dissemination La Trobe University Ethics Committee (HREC 20488) approved. Coaches provided informed consent to receive the supported intervention and players provided consent to be contacted if they sustained a head or knee injury. Results will be disseminated through partner organisations, peer-reviewed publications and scientific conferences.
  •  
5.
  • Solomonidou, A., et al. (författare)
  • Spectral and emissivity analysis of the raised ramparts around Titan's northern lakes
  • 2020
  • Ingår i: Icarus. - : Academic Press. - 0019-1035 .- 1090-2643. ; 344
  • Tidskriftsartikel (refereegranskat)abstract
    • Some of Titan's small northern hemisphere lakes show raised rampart features (which are distinct from raised rims), and appear as SAR-bright mound-like annuli extending away from the lake for up to tens of kilometers from the shoreline. We investigate the infrared and microwave characteristics of these features using Cassini Visual and Infrared Mapping Spectrometer (VIMS) and RADAR data. A spectral comparative analysis is performed among the lakes, their ramparts, and the surrounding regions. We overcome the profound difference in spatial resolution between VIMS and SAR data by using a method that provides overlays between the spectral images and SAR, thus enabling the correct selection of VIMS pixels. The surface properties of the selected areas are obtained using a radiative transfer analysis on the selected VIMS pixels, in addition to emissivity obtained from the RADAR in radiometry mode. Analysis of these combined and co-registered data provides constraints for the formation mechanism(s) of raised ramparts. The results show that the emissivity of the raised ramparts is close to that of Titan's labyrinthic terrains and to that of empty lake floors in the northern polar regions. This is confirmed by the VIMS analysis that also shows that the infrared spectral response of the raised ramparts is very similar to that of some empty lake floors. This suggests that both areas are made from or are covered by a similar material. In addition, two out of the eight lakes with raised ramparts show spectral differences at three specific wavelengths, 1.6, 2.0, and 5.0 mu m, between the ramparts and the surrounding terrain. We hypothesize that this could be due to some component, or mixture of components in the ramparts that is less absorbent at these specific wavelengths, or it could be an effect of different grain sizes. These observations provide first insights into the possible mechanisms leading to the formation of the raised ramparts that are discussed here.
  •  
6.
  • Backis, A., et al. (författare)
  • Time- and energy-resolved effects in the boron-10 based multi-grid and helium-3 based thermal neutron detectors
  • 2021
  • Ingår i: Measurement science and technology. - : IOP PUBLISHING LTD. - 0957-0233 .- 1361-6501. ; 32:3
  • Tidskriftsartikel (refereegranskat)abstract
    • The boron-10 based multi-grid detector is being developed as an alternative to helium-3 based neutron detectors. At the European Spallation Source, the detector will be used for time-of-flight neutron spectroscopy at cold to thermal neutron energies. The objective of this work is to investigate fine time- and energy-resolved effects of the Multi-Grid detector, down to a few mu eV, while comparing it to the performance of a typical helium-3 tube. Furthermore, it is to characterize differences between the detector technologies in terms of internal scattering, as well as the time reconstruction of similar to mu s short neutron pulses. The data were taken at the Helmholtz Zentrum Berlin, where the Multi-Grid detector and a helium-3 tube were installed at the ESS test beamline, V20. Using a Fermi-chopper, the neutron beam of the reactor was chopped into a few tens of mu s wide pulses before reaching the detector, located a few tens of cm downstream. The data of the measurements show an agreement between the derived and calculated neutron detection efficiency curve. The data also provide fine details on the effect of internal scattering, and how it can be reduced. For the first time, the chopper resolution was comparable to the timing resolution of the Multi-Grid detector. This allowed a detailed study of time- and energy resolved effects, as well as a comparison with a typical helium-3 tube.
  •  
7.
  •  
8.
  •  
9.
  • Povoli, M., et al. (författare)
  • 3D silicon detectors for neutron imaging applications
  • 2023
  • Ingår i: Journal of Instrumentation. - : IOP Publishing. - 1748-0221. ; 18:01
  • Tidskriftsartikel (refereegranskat)abstract
    • Neutron detection is of great importance in many fields spanning from scientific research, to nuclear science, and to medical application. The development of silicon-based neutron detectors with enhanced neutron detection efficiency can offer several advantages such as spatial resolution, enhanced dynamic range and background discrimination. In this work, increased detection efficiency is pursued by fabricating high aspect ratio 3D micro-structures filled with neutron converting materials (B4C) on planar silicon detectors. An in-depth feasibility study was carried out in all aspects of the sensor fabrication technology. Passivation of the etched structures was studied in detail, to ensure good electrical performance. The conformal deposition of B4C with a newly developed process showed excellent results. Preliminary electrical characterisation of the completed devices is promising, and detectors have been mounted on dedicated boards in view of the upcoming tests with neutrons.
  •  
10.
  • Povoli, M., et al. (författare)
  • 3D silicon detectors for neutron imaging applications
  • 2023
  • Ingår i: Journal of Instrumentation. - : IOP Publishing Ltd. - 1748-0221. ; 18:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Neutron detection is of great importance in many fields spanning from scientific research, to nuclear science, and to medical application. The development of silicon-based neutron detectors with enhanced neutron detection efficiency can offer several advantages such as spatial resolution, enhanced dynamic range and background discrimination. In this work, increased detection efficiency is pursued by fabricating high aspect ratio 3D micro-structures filled with neutron converting materials (B4C) on planar silicon detectors. An in-depth feasibility study was carried out in all aspects of the sensor fabrication technology. Passivation of the etched structures was studied in detail, to ensure good electrical performance. The conformal deposition of B4C with a newly developed process showed excellent results. Preliminary electrical characterisation of the completed devices is promising, and detectors have been mounted on dedicated boards in view of the upcoming tests with neutrons.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 21

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy