SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Boland W.) srt2:(2010-2014)"

Sökning: WFRF:(Boland W.) > (2010-2014)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • De Jong, R. S., et al. (författare)
  • 4MOST - 4-metre multi-object spectroscopic telescope
  • 2012
  • Ingår i: Proceedings of SPIE - The International Society for Optical Engineering. - : SPIE. - 9780819491473 ; , s. 84460T-
  • Konferensbidrag (refereegranskat)abstract
    • The 4MOST consortium is currently halfway through a Conceptual Design study for ESO with the aim to develop a wide-field (>3 square degree, goal >5 square degree), high-multiplex (>1500 fibres, goal 3000 fibres) spectroscopic survey facility for an ESO 4m-class telescope (VISTA). 4MOST will run permanently on the telescope to perform a 5 year public survey yielding more than 20 million spectra at resolution R∼5000 (λ=390-1000 nm) and more than 2 million spectra at R∼20,000 (395-456.5 nm & 587-673 nm). The 4MOST design is especially intended to complement three key all-sky, space-based observatories of prime European interest: Gaia, eROSITA and Euclid. Initial design and performance estimates for the wide-field corrector concepts are presented. Two fibre positioner concepts are being considered for 4MOST. The first one is a Phi-Theta system similar to ones used on existing and planned facilities. The second one is a new R-Theta concept with large patrol area. Both positioner concepts effectively address the issues of fibre focus and pupil pointing. The 4MOST spectrographs are fixed configuration two-arm spectrographs, with dedicated spectrographs for the high- and low-resolution fibres. A full facility simulator is being developed to guide trade-off decisions regarding the optimal field-of-view, number of fibres needed, and the relative fraction of high-to-low resolution fibres. The simulator takes mock catalogues with template spectra from Design Reference Surveys as starting point, calculates the output spectra based on a throughput simulator, assigns targets to fibres based on the capabilities of the fibre positioner designs, and calculates the required survey time by tiling the fields on the sky. The 4MOST consortium aims to deliver the full 4MOST facility by the end of 2018 and start delivering high-level data products for both consortium and ESO community targets a year later with yearly increments.
  •  
2.
  • Adler, Jan-Olof, et al. (författare)
  • The upgraded photon tagging facility at the MAX IV Laboratory
  • 2013
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - : Elsevier BV. - 0167-5087 .- 0168-9002. ; 715, s. 1-10
  • Tidskriftsartikel (refereegranskat)abstract
    • A description is given of the upgraded photon tagging facility at the MAX IV Laboratory. Two magnetic spectrometers are used to momentum analyze post-bremsstrahlung electrons. The tagged photon range extends from 10 to 180 MeV with an energy resolution of about 300 keV. The system has been operated at rates up to 4 x 10(6) photons s(-1) MeV (-1). Different diagnostic tools are described as well as the experimental program.
  •  
3.
  • Urayama, Kevin Y., et al. (författare)
  • Genome-Wide Association Study of Classical Hodgkin Lymphoma and Epstein-Barr Virus Status-Defined Subgroups
  • 2012
  • Ingår i: Journal of the National Cancer Institute. - Oxford : Oxford University Press (OUP). - 0027-8874 .- 1460-2105. ; 104:3, s. 240-253
  • Tidskriftsartikel (refereegranskat)abstract
    • Accumulating evidence suggests that risk factors for classical Hodgkin lymphoma (cHL) differ by tumor Epstein-Barr virus (EBV) status. This potential etiological heterogeneity is not recognized in current disease classification. We conducted a genome-wide association study of 1200 cHL patients and 6417 control subjects, with validation in an independent replication series, to identify common genetic variants associated with total cHL and subtypes defined by tumor EBV status. Multiple logistic regression was used to calculate odds ratios (ORs) and 95% confidence intervals (CIs) assuming a log-additive genetic model for the variants. All statistical tests were two-sided. Two novel loci associated with total cHL irrespective of EBV status were identified in the major histocompatibility complex region; one resides adjacent to MICB (rs2248462: OR = 0.61, 95% CI = 0.53 to 0.69, P = 1.3 x 10(-13)) and the other at HLA-DRA (rs2395185: OR = 0.56, 95% CI = 0.50 to 0.62, P = 8.3 x 10(-25)) with both results confirmed in an independent replication series. Consistent with previous reports, associations were found between EBV-positive cHL and genetic variants within the class I region (rs2734986, HLA-A: OR = 2.45, 95% CI = 2.00 to 3.00, P = 1.2 x 10(-15); rs6904029, HCG9: OR = 0.46, 95% CI = 0.36 to 0.59, P = 5.5 x 10(-10)) and between EBV-negative cHL and rs6903608 within the class II region (rs6903608, HLA-DRA: OR = 2.08, 95% CI = 1.84 to 2.35, P = 6.1 x 10(-31)). The association between rs6903608 and EBV-negative cHL was confined to the nodular sclerosis histological subtype. Evidence for an association between EBV-negative cHL and rs20541 (5q31, IL13: OR = 1.53, 95% CI = 1.32 to 1.76, P = 5.4 x 10(-9)), a variant previously linked to psoriasis and asthma, was observed; however, the evidence for replication was less clear. Notably, one additional psoriasis-associated variant, rs27524 (5q15, ERAP1), showed evidence of an association with cHL in the genome-wide association study (OR = 1.21, 95% CI = 1.10 to 1.33, P = 1.5 x 10(-4)) and replication series (P = .03). Overall, these results provide strong evidence that EBV status is an etiologically important classification of cHL and also suggest that some components of the pathological process are common to both EBV-positive and EBV-negative patients.
  •  
4.
  • Wootton, K. P., et al. (författare)
  • Storage ring lattice calibration using resonant spin depolarization
  • 2013
  • Ingår i: Physical Review Special Topics. Accelerators and Beams. - 1098-4402. ; 16:7
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper presents measurements of the GeV-scale electron beam energy for the storage rings at the synchrotron light source facilities Australian Synchrotron (AS) and SPEAR3 at SLAC. Resonant spin depolarization was employed in the beam energy measurement, since it is presently the highest precision technique and an uncertainty of order 10(-6) was achieved at SPEAR3 and AS. Using the resonant depolarization technique, the beam energy was measured at various rf frequencies to measure the linear momentum compaction factor. This measured linear momentum compaction factor was used to evaluate models of the beam trajectory through combined-function bending magnets. The main bending magnets of both lattices are rectangular, horizontally defocusing gradient bending magnets. Four modeling approaches are compared for the beam trajectory through the bending magnet: a circular trajectory, linear and nonlinear hyperbolic cosine trajectories, and numerical evaluation of the trajectory through the measured magnetic field map. Within the uncertainty of the measurement the momentum compaction factor is shown to agree with the numerical model of the trajectory within the bending magnet, and disagree with the hyperbolic cosine approximation.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy