SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Bolejko Anetta) srt2:(2015-2019)"

Sökning: WFRF:(Bolejko Anetta) > (2015-2019)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Bolejko, Anetta, et al. (författare)
  • Prevalence, Long-term Development, and Predictors of Psychosocial Consequences of False-Positive Mammography among Women Attending Population-Based Screening
  • 2015
  • Ingår i: Cancer Epidemiology, Biomarkers and Prevention. - : American Association for Cancer Research. - 1055-9965 .- 1538-7755. ; 24:9, s. 1388-1397
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Cancer screening aims to detect cancer at an asymptomatic stage, although side effects from screening also occur. We investigated the prevalence, longitudinal development, and predictors of psychosocial consequences of false-positive breast cancer screening. METHODS: Three hundred ninety-nine women with false-positive screening mammography responded to the Consequences of Screening-Breast Cancer (COS-BC) questionnaire immediately after a negative diagnosis (free from breast cancer) following recall examination(s) (baseline), and 6 and 12 months later. Age-matched controls (n = 499) with a negative mammogram responded to the COS-BC at the same occasions. Five COS-BC scales (Sense of dejection, Anxiety, Behavioral, Sleep, and Existential values) were used as outcome measures. RESULTS: Women with false-positive mammography had consistently higher prevalence of all five consequences compared with controls (P < 0.001). The prevalences decreased between baseline and 6 months (P < 0.001) but were stable between 6 and 12 months (P ≥ 0.136). Early recall profoundly predicted long-term consequences for all five outcomes (OR, 3.05-10.31), along with dissatisfaction with information at recall (OR, 2.28-2.56), being foreign-born (OR, 2.35-3.71), and lack of social support (OR, 1.13-1.25). CONCLUSION: This 1-year longitudinal study shows that women experience psychosocial consequences of false-positive screening mammography. Early recall should be performed cautiously, and provision of information as well as social support may reduce psychosocial consequences. IMPACT: Although delivery of population-based screening reduces breast cancer mortality, it also raises the issue of its impact on the psychosocial well-being of healthy women. Our findings identify predictors that can be targeted in future efforts to reduce the side effects of mammographic screening.
  •  
2.
  •  
3.
  • Phexell, Erika, et al. (författare)
  • Intra- and inter-rater reliability in a comparative study of cross-sectional and spiral computed tomography pelvimetry methods
  • 2019
  • Ingår i: Acta Radiologica Open. - : SAGE Publications. - 2058-4601. ; 8:6
  • Tidskriftsartikel (refereegranskat)abstract
    • Different low-dose computed tomography (CT) pelvimetry methods can be used to evaluate the size of birth canal before delivery. CT pelvimetry might generate an acceptable low fetal radiation dose but its measurement accuracy is unknown. Purpose To investigate intra- and inter-rater measurement reliability of cross-sectional and two spiral CT pelvimetry methods: standard spiral and short spiral. Material and Methods Ten individuals (age ≥60 years, body mass index ≥30 kg/m2) having a CT scan of the abdomen also had CT pelvimetry scans. Three radiologists made independent measurements of each pelvimetry method on two occasions and also in consensus for a reference pelvimetry computed from the standard-dose CT scan of the abdomen. Inter- and intra-rater reliability was analyzed by intraclass correlation coefficient. Results Measurements in the short spiral pelvimetry demonstrated excellent intra- and inter-rater reliability, intraclass correlation coefficient ≥0.93, and good to excellent 95% confidence interval 0.87–0.99. Corresponding results of the standard spiral and cross-sectional pelvimetry showed good to excellent intraclass correlation coefficient ≥0.85 and ≥0.76, and 95% confidence interval was least good and moderate 0.73–0.98 and 0.59–0.97, respectively. Intraclass correlation coefficient between reference pelvimetry and other CT methods showed analogous results. Conclusion The short spiral pelvimetry demonstrated high and best reliability in comparison to other methods. Standard spiral method showed also good measurement reliability but the short spiral pelvimetry generates lower fetal radiation dose. This method might be suitable for measurements at narrow pelvis. Patient acceptance and attitude to CT pelvimetry should be investigated.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy