SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Bornefalk Hans) srt2:(2020-2022)"

Sökning: WFRF:(Bornefalk Hans) > (2020-2022)

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Ahmadi, Zainab, et al. (författare)
  • Agreement of the modified Medical Research Council and New York Heart Association scales for assessing the impact of self-rated breathlessness in cardiopulmonary disease
  • 2022
  • Ingår i: ERJ Open Research. - : European Respiratory Society. - 2312-0541. ; 8:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: The functional impact of breathlessness is assessed using the modified Medical Research Council (mMRC) scale for chronic respiratory disease and with the New York Heart Association Functional Classification (NYHA) scale for heart failure. We evaluated agreement between the scales and their concurrent validity with other clinically relevant patient-reported outcomes in cardiorespiratory disease.Methods: Outpatients with stable chronic respiratory disease or heart failure were recruited. Agreement between the mMRC and NYHA scales was analysed using Cramér's V and Kendall's tau B tests. Concurrent validity was evaluated using correlations with clinically relevant measures of breathlessness, anxiety, depression, and health-related quality of life. Analyses were conducted for all participants and separately in chronic obstructive pulmonary disease (COPD) and heart failure.Results: In a total of 182 participants with cardiorespiratory disease, the agreement between the mMRC and NYHA scales was moderate (Cramér's V: 0.46; Kendall's tau B: 0.57) with similar results for COPD (Cramér's V: 0.46; Kendall's tau B: 0.66) and heart failure (Cramér's V: 0.46; Kendall's tau B: 0.67). In the total population, the scales correlated in similar ways to other patient-reported outcomes.Conclusion: In outpatients with cardiorespiratory disease, the mMRC and NYHA scales show moderate to strong correlations and similar associations with other patient-reported outcomes. This supports that the scales are comparable when assessing the impact of breathlessness on function and patient-reported outcomes.
  •  
2.
  • Ekström, Magnus, et al. (författare)
  • Minimal clinically important differences for Dyspnea-12 and MDP scores are similar at 2 weeks and 6 months : follow-up of a longitudinal clinical study
  • 2021
  • Ingår i: The European respiratory journal. - : European Respiratory Society (ERS). - 1399-3003 .- 0903-1936. ; 57:3
  • Tidskriftsartikel (refereegranskat)abstract
    • Chronic breathlessness is a dominating symptom that restricts daily life for many people with cardiorespiratory disease [1]. Different dimensions of the symptom, such as the intensity, sensory qualities and emotional responses, can be assessed using the instruments Dyspnea-12 (D-12) [2] and the Multidimensional Dyspnea Profile (MDP) [3], which share similarities in the underlying constructs of what is measured [4] and have emerged as widely used instruments for multi-dimensional measurement of breathlessness
  •  
3.
  • Ekström, Magnus P., et al. (författare)
  • Minimal Clinically Important Differences and Feasibility of Dyspnea-12 and the Multidimensional Dyspnea Profile in Cardiorespiratory Disease
  • 2020
  • Ingår i: Journal of Pain and Symptom Management. - : Elsevier. - 0885-3924 .- 1873-6513. ; 60:5, s. 968-975
  • Tidskriftsartikel (refereegranskat)abstract
    • Context: Breathlessness is a cardinal symptom in cardiorespiratory disease and consists of multiple dimensions that can be measured using the instruments Dyspnea-12 (D12) and the Multidimensional Dyspnea Profile (MDP). Objectives: The objective of the study is to determine the minimal clinically important differences (MCIDs) of all D12 and MDP summary and subdomain scores as well as the instruments' feasibility in patients with cardiorespiratory disease. Methods: Prospective multicenter cohort study of outpatients with diagnosed cardiorespiratory disease and breathlessness in daily life. D12 and MDP were assessed at baseline, after 30-90 minutes and two weeks. MCIDs were calculated using anchor-based and distributional methods for summary and subdomain scores. Feasibility was assessed as rate of missing data, help required, self-reported difficulty, and completion time. Results: A total 182 outpatients (53.3% women) were included; main diagnoses were chronic obstructive pulmonary disease (COPD; 25%), asthma (21%), heart failure (19%), and idiopathic pulmonary fibrosis (19%). Anchor-based MCIDs were for D12 total score 2.83 (95% CI 1.99-3.66); D12 physical 1.81 (1.29-2.34); D12 affective 1.07 (0.64-1.49); MDP A1 unpleasantness 0.82 (0.56-1.08); MDP perception 4.63 (3.21-6.05), and MDP emotional score 2.37 (1.10-3.64). The estimates were consistent with small-to-moderate effect sizes using distributional analysis, and MCIDs were similar between COPD and non-COPD patients. The instruments were generally feasible and quick to use. Conclusion: D12 and MDP are responsive to change and feasible for use for assessing multidimensional breathlessness in outpatients with cardiorespiratory disease. MCIDs were determined for use as endpoints in clinical trials.
  •  
4.
  • Bornefalk, Hans, et al. (författare)
  • Calibration of an x-ray imaging system
  • 2022
  • Patent (populärvet., debatt m.m.)abstract
    • Disclosed is a calibration phantom for an x-ray imaging system having an x-ray source and an x-ray detector. The calibration phantom includes a combination of geometric objects of at least three different types and/or compositions including: a first object located in the middle, including a first material; a plurality of second objects arranged around the periphery of the first object, at least a subset of the second objects including a second material different than the first material, wherein the first object is relatively larger than the second objects; a plurality of third objects arranged around the periphery of the first object and/or around the periphery of at least a subset of the second objects, at least a subset of the third objects including a third material different than the first material and the second material, wherein the third objects are relatively smaller than the second objects.
  •  
5.
  • Bornefalk, Hans, et al. (författare)
  • Enhanced spectral x-ray imaging
  • 2021
  • Patent (populärvet., debatt m.m.)abstract
    • An x-ray imaging apparatus includes an x-ray source and detector with multiple detector elements. The source and detector are on a support that rotates around a subject, enabling projections at different view angles. The apparatus operates the x-ray source in switched kVp mode for alternately applying different voltages, including lower and higher voltages, during rotation to enable lower-energy and higher-energy exposures over the projections, providing for lower-energy projections and higher-energy projections. The x-ray detector is a photon-counting multi-bin detector allocating photon counts to multiple energy bins, and the apparatus selects counts from at least a subset of the bins to provide corresponding photon count information for both lower- and higher-energy projections. The apparatus performs material basis decomposition for some of the lower-energy projections and higher-energy projections and/or for some combinations of at least one lower-energy projection and at least one higher-energy projection, based on the corresponding photon count information.
  •  
6.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy