SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Bourgeois J.) srt2:(2020-2024)"

Sökning: WFRF:(Bourgeois J.) > (2020-2024)

  • Resultat 1-10 av 10
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  • Aalbers, Jelle, et al. (författare)
  • Solar neutrino detection sensitivity in DARWIN via electron scattering
  • 2020
  • Ingår i: European Physical Journal C. - : Springer Science and Business Media LLC. - 1434-6044 .- 1434-6052. ; 80:12
  • Tidskriftsartikel (refereegranskat)abstract
    • We detail the sensitivity of the proposed liquid xenon DARWIN observatory to solar neutrinos via elastic electron scattering. We find that DARWIN will have the potential to measure the fluxes of five solar neutrino components: pp, 7Be, 13N, 15O and pep. The precision of the 13N, 15O and pep components is hindered by the double-beta decay of 136Xe and, thus, would benefit from a depleted target. A high-statistics observation of pp neutrinos would allow us to infer the values of the electroweak mixing angle, sin2 theta w, and the electron-type neutrino survival probability, Pee, in the electron recoil energy region from a few keV up to 200 keV for the first time, with relative precision of 5% and 4%, respectively, with 10 live years of data and a 30 tonne fiducial volume. An observation of pp and 7Be neutrinos would constrain the neutrino-inferred solar luminosity down to 0.2%. A combination of all flux measurements would distinguish between the high- (GS98) and low-metallicity (AGS09) solar models with 2.1-2.5 sigma significance, independent of external measurements from other experiments or a measurement of 8B neutrinos through coherent elastic neutrino-nucleus scattering in DARWIN. Finally, we demonstrate that with a depleted target DARWIN may be sensitive to the neutrino capture process of 131Xe.
  •  
4.
  • Aalbers, J., et al. (författare)
  • A next-generation liquid xenon observatory for dark matter and neutrino physics
  • 2023
  • Ingår i: Journal of Physics G: Nuclear and Particle Physics. - : IOP Publishing. - 0954-3899 .- 1361-6471. ; 50:1
  • Forskningsöversikt (refereegranskat)abstract
    • The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for weakly interacting massive particles, while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neutrinos through neutrinoless double-beta decay and through a variety of astrophysical sources. A next-generation xenon-based detector will therefore be a true multi-purpose observatory to significantly advance particle physics, nuclear physics, astrophysics, solar physics, and cosmology. This review article presents the science cases for such a detector.
  •  
5.
  • Maier, N., et al. (författare)
  • Efficacy of an Enterotoxigenic Escherichia coli (ETEC) Vaccine on the Incidence and Severity of Traveler's Diarrhea (TD): Evaluation of Alternative Endpoints and a TD Severity Score
  • 2023
  • Ingår i: Microorganisms. - 2076-2607. ; 11:10
  • Tidskriftsartikel (refereegranskat)abstract
    • The efficacy of an Oral Whole Cell ETEC Vaccine (OEV) against Travelers' Diarrhea (TD) was reexamined using novel outcome and immunologic measures. More specifically, a recently developed disease severity score and alternative clinical endpoints were evaluated as part of an initial validation effort to access the efficacy of a vaccine intervention for the first time in travelers to an ETEC endemic area. A randomized, double-blind, placebo-controlled trial followed travelers to Guatemala or Mexico up to 28 days after arrival in the country following vaccination (two doses two weeks apart) with an ETEC vaccine. Fecal samples were collected upon arrival, departure, and during TD for pathogen identification. Serum was collected in a subset of subjects to determine IgA cholera toxin B subunit (CTB) antibody titers upon their arrival in the country. The ETEC vaccine's efficacy, utilizing a TD severity score and other alternative endpoints, including the relationship between antibody levels and TD risk, was assessed and compared to the per-protocol primary efficacy endpoint. A total of 1435 subjects completed 7-28 days of follow-up and had available data. Vaccine efficacy was higher against more severe (>= 5 unformed stools/24 h) ETEC-attributable TD and when accounting for immunologic take (PE >= 50%; p < 0.05). The vaccine protected against less severe (3 and 4 unformed stools/24 h) ETEC-attributable TD when accounting for symptom severity or change in activity (PE = 76.3%, p = 0.01). Immunologic take of the vaccine was associated with a reduced risk of infection with ETEC and other enteric pathogens, and with lower TD severity. Clear efficacy was observed among vaccinees with a TD score of >= 4 or >= 5, regardless of immunologic take (PE = 72.0% and 79.0%, respectively, p <= 0.03). The vaccine reduced the incidence and severity of ETEC, and this warrants accelerated evaluation of the improved formulation (designated ETVAX), currently undergoing advanced field testing. Subjects with serum IgA titers to CTB had a lower risk of infection with ETEC and Campylobacter jejuni/coli. Furthermore, the TD severity score provided a more robust descriptor of disease severity and should be included as an endpoint in future studies.
  •  
6.
  • Maitrallain, A., et al. (författare)
  • Parametric study of high-energy ring-shaped electron beams from a laser wakefield accelerator
  • 2022
  • Ingår i: New Journal of Physics. - : IOP Publishing. - 1367-2630. ; 24:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Laser wakefield accelerators commonly produce on-axis, low-divergence, high-energy electron beams. However, a high charge, annular shaped beam can be trapped outside the bubble and accelerated to high energies. Here we present a parametric study on the production of low-energy-spread, ultra-relativistic electron ring beams in a two-stage gas cell. Ring-shaped beams with energies higher than 750 MeV are observed simultaneously with on axis, continuously injected electrons. Often multiple ring shaped beams with different energies are produced and parametric studies to control the generation and properties of these structures were conducted. Particle tracking and particle-in-cell simulations are used to determine properties of these beams and investigate how they are formed and trapped outside the bubble by the wake produced by on-axis injected electrons. These unusual femtosecond duration, high-charge, high-energy, ring electron beams may find use in beam driven plasma wakefield accelerators and radiation sources.
  •  
7.
  • Streeter, M. J.V., et al. (författare)
  • Characterization of laser wakefield acceleration efficiency with octave spanning near-IR spectrum measurements
  • 2022
  • Ingår i: Physical Review Accelerators and Beams. - 2469-9888. ; 25:10
  • Tidskriftsartikel (refereegranskat)abstract
    • We report on experimental measurements of energy transfer efficiencies in a GeV-class laser wakefield accelerator. Both the transfer of energy from the laser to the plasma wakefield and from the plasma to the accelerated electron beam was diagnosed by simultaneous measurement of the deceleration of laser photons and the acceleration of electrons as a function of plasma length. The extraction efficiency, which we define as the ratio of the energy gained by the electron beam to the energy lost by the self-guided laser mode, was maximized at 19±3% by tuning the plasma density and length. The additional information provided by the octave-spanning laser spectrum measurement allows for independent optimization of the plasma efficiency terms, which is required for the key goal of improving the overall efficiency of laser wakefield accelerators.
  •  
8.
  • Cassetta, L, et al. (författare)
  • Differential expansion of circulating human MDSC subsets in patients with cancer, infection and inflammation
  • 2020
  • Ingår i: Journal for immunotherapy of cancer. - : BMJ. - 2051-1426. ; 8:2
  • Tidskriftsartikel (refereegranskat)abstract
    • Myeloid-derived suppressor cells (MDSC) are a functional myeloid cell subset that includes myeloid cells with immune suppressive properties. The presence of MDSC has been reported in the peripheral blood of patients with several malignant and non-malignant diseases. So far, direct comparison of MDSC across different diseases and Centers is hindered by technical pitfalls and a lack of standardized methodology. To overcome this issue, we formed a network through the COST Action Mye-EUNITER (www.mye-euniter.eu) with the goal to standardize and facilitate the comparative analysis of human circulating MDSC in cancer, inflammation and infection. In this manuscript, we present the results of the multicenter study Mye-EUNITER MDSC Monitoring Initiative, that involved 13 laboratories and compared circulating MDSC subsets across multiple diseases, using a common protocol for the isolation, identification and characterization of these cells.MethodsWe developed, tested, executed and optimized a standard operating procedure for the isolation and immunophenotyping of MDSC using blood from healthy donors. We applied this procedure to the blood of almost 400 patients and controls with different solid tumors and non-malignant diseases. The latter included viral infections such as HIV and hepatitis B virus, but also psoriasis and cardiovascular disorders.ResultsWe observed that the frequency of MDSC in healthy donors varied substantially between centers and was influenced by technical aspects such as the anticoagulant and separation method used. Expansion of polymorphonuclear (PMN)-MDSC exceeded the expansion of monocytic MDSC (M-MDSC) in five out of six solid tumors. PMN-MDSC expansion was more pronounced in cancer compared with infection and inflammation. Programmed death-ligand 1 was primarily expressed in M-MDSC and e-MDSC and was not upregulated as a consequence of disease. LOX-1 expression was confined to PMN-MDSC.ConclusionsThis study provides improved technical protocols and workflows for the multi-center analysis of circulating human MDSC subsets. Application of these workflows revealed a predominant expansion of PMN-MDSC in solid tumors that exceeds expansion in chronic infection and inflammation.
  •  
9.
  • Kepp, Kasper P., et al. (författare)
  • Panel stacking is a threat to consensus statement validity
  • 2024
  • Ingår i: Journal of Clinical Epidemiology. - : Elsevier. - 0895-4356 .- 1878-5921. ; 173
  • Tidskriftsartikel (refereegranskat)abstract
    • Consensus statements can be very influential in medicine and public health. Some of these statements use systematic evidence synthesis but others fail on this front. Many consensus statements use panels of experts to deduce perceived consensus through Delphi processes. We argue that stacking of panel members toward one particular position or narrative is a major threat, especially in absence of systematic evidence review. Stacking may involve financial conflicts of interest, but nonfinancial conflicts of strong advocacy can also cause major bias. Given their emerging importance, we describe here how such consensus statements may be misleading, by analyzing in depth a recent high-impact Delphi consensus statement on COVID-19 recommendations as a case example. We demonstrate that many of the selected panel members and at least 35% of the core panel members had advocated toward COVID-19 elimination (Zero-COVID) during the pandemic and were leading members of aggressive advocacy groups. These advocacy conflicts were not declared in the Delphi consensus publication, with rare exceptions. Therefore, we propose that consensus statements should always require rigorous evidence synthesis and maximal transparency on potential biases toward advocacy or lobbyist groups to be valid. While advocacy can have many important functions, its biased impact on consensus panels should be carefully avoided.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 10

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy