SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Brodin Ola) srt2:(2015-2019)"

Sökning: WFRF:(Brodin Ola) > (2015-2019)

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Brodin, Ola, et al. (författare)
  • Pharmacokinetics and Toxicity of Sodium Selenite in the Treatment of Patients with Carcinoma in a Phase I Clinical Trial: The SECAR Study
  • 2015
  • Ingår i: Nutrients. - : MDPI. - 2072-6643. ; 7:6, s. 4978-4994
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Sodium selenite at high dose exerts antitumor effects and increases efficacy of cytostatic drugs in multiple preclinical malignancy models. We assessed the safety and efficacy of intravenous administered sodium selenite in cancer patients refractory to cytostatic drugs in a phase I trial. Patients received first line of chemotherapy following selenite treatment to investigate altered sensitivity to these drugs and preliminary assessment of any clinical benefits. Materials and Methods: Thirty-four patients with different therapy resistant tumors received iv sodium selenite daily for consecutive five days either for two weeks or four weeks. Each cohort consisted of at least three patients who received the same daily dose of selenite throughout the whole treatment. If 0/3 patients had dose-limiting toxicities (DLTs), the study proceeded to the next dose-level. If 2/3 had DLT, the dose was considered too high and if 1/3 had DLT, three more patients were included. Dose-escalation continued until the maximum tolerated dose (MTD) was reached. MTD was defined as the highest dose-level on which 0/3 or 1/6 patients experienced DLT. The primary endpoint was safety, dose-limiting toxic effects and the MTD of sodium selenite. The secondary endpoint was primary response evaluation. Results and Conclusion: MTD was defined as 10.2 mg/m(2), with a calculated median plasma half-life of 18.25 h. The maximum plasma concentration of selenium from a single dose of selenite increased in a nonlinear pattern. The most common adverse events were fatigue, nausea, and cramps in fingers and legs. DLTs were acute, of short duration and reversible. Biomarkers for organ functions indicated no major systemic toxicity. In conclusion, sodium selenite is safe and tolerable when administered up to 10.2 mg/m(2) under current protocol. Further development of the study is underway to determine if prolonged infusions might be a more effective treatment strategy.
  •  
2.
  • Frånberg, Oskar, 1976- (författare)
  • Oxygen content in semi-closed rebreathing apparatuses for underwater use : Measurements and modeling
  • 2015
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • The present series of unmanned hyperbaric tests were conducted in order to investigate the oxygen fraction variability in semi-closed underwater rebreathing apparatuses. The tested rebreathers were RB80 (Halcyon dive systems, High springs, FL, USA), IS-Mix (Interspiro AB, Stockholm, Sweden), CRABE (Aqua Lung, Carros Cedex, France), and Viper+ (Cobham plc, Davenport, IA, USA). The tests were conducted using a catalytically based propene combusting metabolic simulator. The metabolic simulator connected to a breathing simulator, both placed inside a hyperbaric pressure chamber, was first tested to demonstrate its usefulness to simulate human respiration in a hyperbaric situation. Following this the metabolic simulator was shown to be a useful tool in accident investigations as well as to assess the impact of different engineering designs and physiological variables on the oxygen content in the gas delivered to the diver by the rebreathing apparatuses. A multi-compartment model of the oxygen fractions was developed and compared to the previously published single-compartment models. The root mean squared error (RMSE) of the multi-compartment model was smaller than the RMSE for the single-compartment model, showing its usefulness to estimate the impact of different designs and physiological variables on the inspired oxygen fraction.
  •  
3.
  • Mellin, Pelle, et al. (författare)
  • Evaluating flowability of additive manufacturing powders, using the gustavsson flow meter
  • 2016
  • Ingår i: World PM 2016 Congress and Exhibition. - : European Powder Metallurgy Association (EPMA). - 9781899072484
  • Konferensbidrag (refereegranskat)abstract
    • The Gustavsson flow meter (including standard ISO-13517) is in this paper used to measure flow rate of fine AM powders. In the current paper, the results are compared to the Hall flow meter and a Freeman FT4 powder rheometer in terms of success of measuring these AM powders. The robustness is clearly superior to the Hall flow meter. Compared to using the rheometer, the Gustavsson flow meter is faster and simpler to use; however, other powder-aspects are evaluated since little correlation was found. All methods of characterizing the flowability could distinguish between (1) two alloys, and (2) if the alloys were new or used (in SLM), and (3) if they were dried or non-dried.
  •  
4.
  • Mellin, Pelle, et al. (författare)
  • Evaluating flowability of additive manufacturing powders, using the Gustavsson flow meter
  • 2017
  • Ingår i: Metal Powder Report. - : Elsevier Ltd. - 0026-0657 .- 1873-4065. ; 72:5, s. 322-326
  • Tidskriftsartikel (refereegranskat)abstract
    • The Gustavsson flow meter (including standard ISO-13517) is in this paper used to measure flow rate of fine AM powders. In the current paper, the results are compared to the Hall flow meter and a Freeman FT4 powder rheometer in terms of success of measuring these AM powders. The range of possible powders to measure is smaller with Gustavsson flow meter; but in this range, the difference in flow time is greater compared to the Hall flow meter. Compared to using the rheometer, the Gustavsson flow meter is faster and simpler to use; however, other powder-aspects are evaluated since little correlation was found. For the powders in this paper, all methods of characterizing the flowability could distinguish between (1) two alloys, and (2) if the alloys were new or used (in SLM), and (3) if they were dried or non-dried.
  •  
5.
  • Strondl, Annika, et al. (författare)
  • Characterization and Control of Powder Properties for Additive Manufacturing
  • 2015
  • Ingår i: JOM. - : Springer Science and Business Media LLC. - 1047-4838 .- 1543-1851. ; 67:3, s. 549-554
  • Tidskriftsartikel (refereegranskat)abstract
    • Powder characterization and handling in powder metallurgy are important issues and the required powder properties will vary between different component manufacturing processes. By understanding and controlling these, the final material properties for different applications can be improved and become more reliable. In this study, the metal powders used in additive manufacturing (AM) in terms of electron beam melting and selective laser melting have been investigated regarding particle size and shape using dynamic image analysis. In parallel, powder flow characteristics have been evaluated with a powder rheometer. Correlations within the results have been found between particle shape and powder flow characteristics that could explain certain effects of the powder processing in the AM processes. The impact, however, in the processing performance as well as in ultimate material properties was found to be limited.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy