SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Brolin Hans) srt2:(2005-2009)"

Sökning: WFRF:(Brolin Hans) > (2005-2009)

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  • Halldin, Peter, et al. (författare)
  • Finite element analysis of the effects of head-supported mass on neck responses : Complete phase three report, united states army european research office of the U.S.army
  • 2006
  • Rapport (refereegranskat)abstract
    • The objectives for the whole project were to: I. determine the relationships between head supported mass and the risk of neck injuries. The results should be used in a Graphical user interface. In this phase three report has also the Graphical User Interface (GUI) been evaluated and the question about the how the muscle activation affect the injury risk. II. to develop and implement a 3D numerical muscle model. Results: I. The KTH neck model has successfully been used to generate results for the GUI. Results from all simulations have been reported and sent to Titan Corporation that is contracted by USAARL to program the GUI. The GUI that uses an interpolation method to calculate the neck injury risk for a general helmet with a user defined HSM configuration shows to give realistic interpolated values compared to the FE model of the neck. II. The 3D muscle model for the cervical spine includes 22 pairs of muscles. The solid muscle model showed to stabilize the vertebral column better than the spring muscle model. The model is still under evaluation and need further validation to be used in the HSM evaluation project.
  •  
4.
  •  
5.
  • Nordberg, Axel, et al. (författare)
  • Vertebral fractures fixation with composite patch fibre reinforced adhesives
  • 2007
  • Ingår i: Bio-medical materials and engineering. - 0959-2989 .- 1878-3619. ; 17:5, s. 299-308
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: The aim is to investigate fixation of cervical vertebral fractures by patching it with a composite laminate of adhesive and fibres, in comparison with use of only adhesives. Material and methods: The composite fixation was tested on bonded roe deer vertebrae. 25 specimens were sawed in two halves, creating a generic fracture, and thereafter bonded. The adhesives used were a dental system, Scotchbond XT, and a cyanoacrylate, M-bond 200. The fibres used were unidirectional carbon fibres and randomly distributed E-glass fibres. The composites were applied as a 7 mm wide patch circumferential along the induced fracture. Reference specimens for comparison were also made. The ultimate tensile strength was tested in an Instron 5567. The failure site was examined with a microscope. Strain vectors were tracked using Digital Speckle Analysis. Results: Scotchbond XT + E-glass fibres gave best results, with a tensile strength of 3.5 N/mm circumferential length (24.3% of reference). All composites had lower stiffness than cortical bone. The dental adhesive fibre composites gave better results than the cyanoacrylate fibre composites. In all cases fibre reinforced adhesive composite gave better results than adhesive without fibre reinforcement. Conclusion: Fibre-adhesive composite is a promising technique for fixating cervical vertebral fractures.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5
Typ av publikation
tidskriftsartikel (3)
rapport (2)
Typ av innehåll
refereegranskat (5)
Författare/redaktör
von Holst, Hans (5)
Brolin, Karin (5)
Halldin, Peter (3)
Hedenstierna, Sofia (3)
Nordberg, Axel (2)
Aare, Magnus (1)
visa fler...
Beckman, Anders (1)
visa färre...
Lärosäte
Kungliga Tekniska Högskolan (5)
Karolinska Institutet (1)
Språk
Engelska (5)
Forskningsämne (UKÄ/SCB)
Teknik (5)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy