SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Button Terry)
 

Search: WFRF:(Button Terry) > High resolution pin...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

High resolution pinhole SPECT for tumor imaging

Strand, Sven-Erik (author)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Ivanovic, Marijana (author)
Erlandsson, Kjell (author)
show more...
Weber, David A (author)
Franceschi, Dinko (author)
Button, Terry (author)
Sjögreen Gleisner, Katarina (author)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
show less...
 (creator_code:org_t)
2009-07-08
1993
English.
In: Acta Oncologica. - : Informa UK Limited. - 1651-226X .- 0284-186X. ; 32:7-8, s. 861-867
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • High-resolution, non-invasive, 3D-imaging techniques would greatly benefit the investigation of the localization properties of tumor-specific radiopharmaceuticals in laboratory animals. The present study reports how pinhole SPECT can be applied to tumor localization studies in small laboratory animals to provide high resolution SPECT images in vivo. Pinhole SPECT was performed using a rotating scintillation camera, equipped with a pinhole collimator. The sensitivity of a 2 mm diameter collimator at 45 mm from the source is 90 cps/MBq for 99mTc. The planar spatial resolution at a 45 mm distance is 2.2 mm. The transaxial spatial resolution, with a distance of 45 mm between the collimator aperture and the axis of rotation, is 3.1 mm. For SPECT imaging, spatial linearity is preserved across the usable field-of-view. The major advantage of the high resolution properties of pinhole tomography is demonstrated by the enhanced lesion-to-normal-brain uptake ratio achieved on tomographic slices as compared to planar images. For example, 201Tl tumor-to-normal-brain uptake ratios of 1.1 to 1.3 observed on planar images, corresponded to ratios ranging from 3.2 to 3.7 on the SPECT slices. Examples of the activity distributions of two radiopharmaceuticals in tumor and in normal brain for sagittal and coronal images are given. In all cases, tumors are clearly delineated on the pinhole SPECT slices. The present study shows that pinhole SPECT performed with standard SPECT instrumentation can give high spatial resolution images, with a FWHM approximately 3 mm and a sensitivity approximately 100 cps/MBq for 99mTc.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Cancer och onkologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cancer and Oncology (hsv//eng)

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view