SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(CLINE D) srt2:(2005-2009)"

Sökning: WFRF:(CLINE D) > (2005-2009)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Achterberg, A., et al. (författare)
  • The search for muon neutrinos from northern hemisphere gamma-ray bursts with AMANDA
  • 2008
  • Ingår i: Astrophysical Journal. - : American Astronomical Society. - 0004-637X .- 1538-4357. ; 674:1, s. 357-370
  • Tidskriftsartikel (refereegranskat)abstract
    • We present the results of the analysis of neutrino observations by the Antarctic Muon and Neutrino Detector Array (AMANDA) correlated with photon observations of more than 400 gamma-ray bursts (GRBs) in the northern hemisphere from 1997 to 2003. During this time period, AMANDA's effective collection area for muon neutrinos was larger than that of any other existing detector. After the application of various selection criteria to our data, we expect similar to 1 neutrino event and <2 background events. Based on our observations of zero events during and immediately prior to the GRBs in the data set, we set the most stringent upper limit on muon neutrino emission correlated with GRBs. Assuming a Waxman-Bahcall spectrum and incorporating all systematic uncertainties, our flux upper limit has a normalization at 1 PeV of E-2 Phi(nu) <= 6.3 x 10(-9) GeV cm(-2) s(-1) sr(-1), with 90% of the events expected within the energy range of similar to 10 TeV to similar to 3 PeV. The impact of this limit on several theoretical models of GRBs is discussed, as well as the future potential for detection of GRBs by next-generation neutrino telescopes. Finally, we briefly describe several modifications to this analysis in order to apply it to other types of transient point sources.
  •  
2.
  • Regan, P H, et al. (författare)
  • Vibrational and rotational sequences in Mo-101 and Ru-103,Ru-4 studied via multinucleon transfer reactions
  • 2005
  • Ingår i: Acta Physica Polonica B. - 0587-4254 .- 1509-5770. ; 36:4, s. 1313-1322
  • Tidskriftsartikel (refereegranskat)abstract
    • The near-yrast states of Mo-101(42)59 and Ru-103,4(44)59,60 have been studied following their population via heavy-ion multinucleon transfer reactions between a Xe-136 beam and a thin, self-supporting Mo-100 target. The ground state sequence in Ru-104 can be understood as demonstrating a simple evolution from a quasi-vibrational structure at lower spins to statically deformed, quasi-rotational excitation involving the population of a pair of low-Omega h(11/2) neutron orbitals. The effect of the decoupled h(11/2) orbital on this vibration-to-rotational evolution is demonstrated by an extension of the "E-GOS" prescription to include odd-A nuclei. The experimental results are also compared with self-consistent Total Routhian Surface calculations which also highlight the polarising role of the highly aligned neutron h(11/2) orbital in these nuclei.
  •  
3.
  • Andersson, V., et al. (författare)
  • Large-Area Balloon-Borne Polarized Gamma Ray Observer (PoGO)
  • 2005
  • Ingår i: Proceedings of the 22nd Texas Symposium on Relativistic Astrophysics at Stanford. ; , s. 736-743
  • Konferensbidrag (refereegranskat)abstract
    • We are developing a new balloon-borne instrument (PoGO), to measure polarization of soft gamma rays (30-200 keV) using asymmetry in azimuth angle distribution of Compton scattering. PoGO is designed to detect 10 % polarization in 100mCrab sources in a 6-8 hour observation and bring a new dimension to studies on gamma ray emission/transportation mechanism in pulsars, AGNs, black hole binaries, and neutron star surface. The concept is an adaptation to polarization measurements of well-type phoswich counter consisting of a fast plastic scintillator (the detection part), a slow plastic scintillator (the active collimator) and a BGO scintillator (the bottom anti-counter). PoGO consists of close-packed array of 217 hexagonal well-type phoswich counters and has a narrow field-of-view (~ 5 deg2) to reduce possible source confusion. A prototype instrument has been tested in the polarized soft gamma-ray beams at Advanced Photon Source (ANL) and at Photon Factory (KEK). On the results, the polarization dependence of EGS4 has been validated and that of Geant4 has been corrected.
  •  
4.
  • Remme, Willem J, et al. (författare)
  • Awareness and perception of heart failure among European cardiologists, internists, geriatricians, and primary care physicians.
  • 2008
  • Ingår i: European Heart Journal. - : Oxford University Press (OUP). - 0195-668X .- 1522-9645. ; 29:14, s. 1739-52
  • Tidskriftsartikel (refereegranskat)abstract
    • AIMS: To assess awareness of heart failure (HF) management recommendations in Europe among cardiologists (C), internists and geriatricians (I/G), and primary care physicians (PCPs). METHODS AND RESULTS: The Study group on HF Awareness and Perception in Europe (SHAPE) surveyed randomly selected C (2041), I/G (1881), and PCP (2965) in France, Germany, Italy, the Netherlands, Poland, Romania, Spain, Sweden, and the UK. Each physician completed a 32-item questionnaire about the diagnosis and treatment of HF (left ventricular ejection fraction <40%). This report provides an analysis of HF awareness among C, I/G, and PCP. Seventy-one per cent I/G and 92% C use echocardiography, and 43% I/G and 82% C use echo-Doppler as a routine diagnostic test (both P < 0.0001). In contrast, 75% PCP use signs and symptoms to diagnose HF. Fewer I/G would use an angiotensin-converting enzyme (ACE)-inhibitor in >90% of their patients (64 vs. 82% C, P < 0.0001), whereas only 47% PCP would routinely prescribe an ACE-inhibitor. Worsening HF was considered a risk of ACE-inhibitor therapy by 35% PCP. I/G and PCP consistently do not prescribe target ACE-inhibitor doses (P < 0.0001 vs. C). Only 39% I/G would use a beta-blocker in >50% of their patients (vs. 73% C, P < 0.0001). Also, only 5% PCP would always, and 35% often, prescribe a beta-blocker and reach target doses in only 7-29%. Moreover, 34% PCP and 26% I/G vs. 11% C (P < 0.0001) do not start a beta-blocker in patients with mild HF, who are already on an ACE-inhibitor and are on diuretic. In mild, stable HF, 39% PCP and 18% I/G would only prescribe diuretics, vs. 7% C (P < 0.0001). In patients with worsening HF in sinus rhythm and on an optimal ACE-inhibitor, beta-blockade and diuretics, significantly more C would add spironolactone, but I/G would more often add digoxin. CONCLUSION: Although each physician group lacks complete adherence to guideline-recommended management strategies, these are used significantly less well by I, G, and PCPs, indicating the need for education of these essential healthcare providers.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy