SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Carlsson Lars 1952) srt2:(2005-2009)"

Sökning: WFRF:(Carlsson Lars 1952) > (2005-2009)

  • Resultat 1-10 av 19
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Carlsson, Lars, 1952, et al. (författare)
  • Minimally invasive surgery vs conventional exposure using the Miller-Galante unicompartmental knee arthroplasty: a randomized radiostereometric study
  • 2006
  • Ingår i: J Arthroplasty. - 0883-5403. ; 21:2, s. 151-6
  • Tidskriftsartikel (refereegranskat)abstract
    • Forty-one patients were randomized to a cemented Miller-Galante unicompartmental (Zimmer, Warsaw, Ind) knee arthroplasty inserted with either minimally invasive surgery or with a standard exposure. Clinical data and conventional radiographs were recorded and patients were followed with radiostereometric analysis to measure migration rate of the tibial component. The rehabilitation of patients operated through a small incision was faster, and there was a significant difference in days of hospitalization (P = .03). No statistical significant difference was found between the 2 groups regarding clinical or radiographic data. The Hospital for Special Surgery score was 96 and 92, respectively, for the minimally invasive surgery and conventional group at 2 years. The limb alignment was equal in both groups with a mean femorotibial axis of 182 degrees after surgery. The rate of migration for tibial components was very small, with a maximal total point motion of 0.8 mm for both groups after 2 years follow-up.
  •  
2.
  • Carlsson, Lars, 1952, et al. (författare)
  • Stepwise introduction of a bone-conserving osseointegrated hip arthroplasty using RSA and a randomized study: II. Clinical proof of concept--40 patients followed for 2 years
  • 2006
  • Ingår i: Acta Orthopaedica. - : Medical Journals Sweden AB. - 1745-3674 .- 1745-3682. ; 77:4, s. 559-566
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: We have developed a bone-conserving commercially pure titanium hip replacement system using osseointegration principles: a metaphyseal loading proximal femoral component affixing into the retained neck and metaphysis only, leaving the femoral canal untouched. The acetabular cup closely fits a dual-geometry cavity, avoiding stress protection at the dome. PATIENTS AND METHODS: After extensive laboratory and clinical pilot trial investigations, the surface-engineered implants were submitted to a prospective randomized controlled clinical trial involving 40 patients (40 hips), in which they were compared to the cemented Spectron femoral component and cementless Trilogy cup as control implant. The following clinical measures were used to monitor progress at regular intervals for the first 2 postoperative years: radiostereometric analysis (RSA), Harris Hip Score, pain score, WOMAC, and SF-36. RESULTS: After 2 years of follow-up, no statistically significant differences were seen between the groups concerning rotation or translation along the cardinal axes. The patients receiving the Gothenburg osseointegrated titanium (GOT) system had significantly higher Harris Hip Score at 6 months, suggesting more rapid recovery. WOMAC, SF-36 and pain analysis were similar for the first 2 postoperative years. INTERPRETATION: Our RSA data suggest that osseointegration was achieved for all patients receiving the GOT hip system. This bone-conserving prosthesis may provide a good alternative, especially for young and active patients.
  •  
3.
  • Hyldahl, H., et al. (författare)
  • All-polyethylene vs. metal-backed tibial component in total knee arthroplasty-a randomized RSA study comparing early fixation of horizontally and completely cemented tibial components: part 1. Horizontally cemented components: AP better fixated than MB
  • 2005
  • Ingår i: Acta Orthop. - : Medical Journals Sweden AB. - 1745-3674 .- 1745-3682. ; 76:6, s. 769-77
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Controversy still exists as to whether to mount the tibial bearing on a metal baseplate or not. Furthermore, the tibial component can be either horizontally or completely cemented. We evaluated metal backing versus all-polyethylene using horizontal cementing technique. PATIENTS AND METHODS: We randomized 40 patients with knee arthrosis (40 knees) to 2 groups: cemented total knee arthroplasty (AGC, Biomet) using either all-polyethylene (AP) or metal-backed (MB) tibial components (n = 20 for each group). All tibial implants had a total thickness of 8 mm. We used proximal cement-ing, including only the horizontal part of the tibia with avoidance of the stem-bone interface. RESULTS: The positioning of the implants, as judged by the HKA angle, showed an average neutral alignment in both groups. Preoperatively and after 2 years, there was no statistically significant difference between the HSS scores in both groups (p = 0.6 and 0.4). After 2 years, the metal-backed components had rotated more around the longitudinal axis, median 0.5 degrees vs. 0.2 degrees (internal or external rotation, p = 0.002), and showed increased maximum total point motion, median 1.0 vs. 0.4 mm (maximum migration or MTPM, p = 0.003). INTERPRETATION: Our study indicates that better fixation can be obtained with the all-polyethylene design if proximally cemented thin components are used.
  •  
4.
  • Hyldahl, H., et al. (författare)
  • All-polyethylene vs. metal-backed tibial component in total knee arthroplasty-a randomized RSA study comparing early fixation of horizontally and completely cemented tibial components: part 2. Completely cemented components: MB not superior to AP components
  • 2005
  • Ingår i: Acta Orthop. - : Medical Journals Sweden AB. - 1745-3674 .- 1745-3682. ; 76:6, s. 778-84
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Uncertainty exists as to whether metal backing (MB) of the tibial component is better than an all-polyethylene component (AP). This is valid for both horizontally and completely cemented components. We evaluated completely cemented MB vs. AP (Part 2). PATIENTS AND METHODS: In a randomized study, 39 patients (40 knees) with knee arthrosis were operated with cemented low-conforming total knee arthroplasty (AGC, Biomet) with a tibial component of uniform thickness (8 mm), cemented both beneath the tibial tray and around the stem. 20 patients had an all-polyethylene (AP) tibial component and 20 patients had an identical but metal-backed (MB) tibial component. We used clinical examination and radiostereometric analysis (RSA) to evaluate the hypothesis that MB improves component fixation. Fixation was evaluated using RSA up to 2 years after surgery. Clinical assessment was performed preoperatively and after 2 years using the Hospital for Special Surgeons (HSS) score. RESULTS: We found no differences in micromotion, and no differences in clinical scores could be detected between the groups at any time point. INTERPRETATION: Our findings indicate that there was equal initial fixation of the AP and MB stemmed monobloc components when they were cemented beneath the tibial plateau and around the stem.
  •  
5.
  • Saari, Tuuli, 1965, et al. (författare)
  • Influence of polyethylene constraint on tibial component fixation in total knee arthroplasty: follow-up report after 5 years
  • 2006
  • Ingår i: J Arthroplasty. - : Elsevier BV. - 0883-5403. ; 21:7, s. 1032-7
  • Tidskriftsartikel (refereegranskat)abstract
    • The influence of articulating surface design of AMK total knee prosthesis (DePuy, Johnson & Johnson) on migration and radiographic outcome at 5 years was evaluated. The knees were randomly allocated to receive a flat or a concave insert with retention of the posterior cruciate ligament when preoperative deformity was less severe and either a concave or a posterior-stabilized insert with resection of the posterior cruciate ligament when deformity was more pronounced. In 64 knees, migration was measured with radiostereometry. The posterior-stabilized component displayed more varus-valgus tilting than the concave insert. Other statistically significant differences in migration were not seen. Radiolucent lines were frequently seen without differences between prosthesis groups.
  •  
6.
  • Saari, Tuuli, 1965, et al. (författare)
  • Joint area constraint had no influence on bone loss in proximal tibia 5 years after total knee replacement
  • 2007
  • Ingår i: J Orthop Res. - : Wiley. - 0736-0266. ; 25:6, s. 798-803
  • Tidskriftsartikel (refereegranskat)abstract
    • After total knee replacement (TKR) the bone mineral density (BMD) decreases in the proximal tibia. Our aim was to evaluate if changes in constraint of the cemented AMK TKR (DePuy, Johnson & Johnson, Leeds, UK) had any effect on postoperative bone remodeling in the proximal tibia. We used dual-energy X-ray absorptiometry in 43-53 knees to record changes in BMD in three regions of interest around the tibial component up to 5 years after operation with the AMK (DePuy) TKR. The knees had been randomly allocated to receive a flat or a concave tibial insert with retention of the posterior cruciate ligament when preoperative deformity was less severe, and either a concave or a posterior-stabilized (PS) insert with resection of the posterior cruciate ligament when deformity was more pronounced. All designs were associated with loss of BMD in the proximal tibia. The mean bone loss varied from 5 to 23% depending on the region of interest. There were no statistically significant differences between the groups, and the alteration of tibial insert constraint did not influence the bone remodeling. However, low precision values may have impaired the detection of differences.
  •  
7.
  • Saari, Tuuli, 1965, et al. (författare)
  • Posterior stabilized component increased femoral bone loss after total knee replacement. 5-year follow-up of 47 knees using dual energy X-ray absorptiometry
  • 2006
  • Ingår i: Knee. - 0968-0160. ; 13:6, s. 435-9
  • Tidskriftsartikel (refereegranskat)abstract
    • After total knee replacement (TKR) bone mineral density (BMD) commonly decreases behind the anterior flange of the femoral component, which may increase the risk for supracondylar fracture. Our aim was to evaluate if changes in femoral design and joint area constraint had any effect on the postoperative bone remodeling in the distal femur. We used dual-energy X-ray absorptiometry in 47 knees up to 5 years after operation with the AMK (DePuy, Johnson and Johnson Leeds, UK) TKR. The knees had been randomly allocated to receive a flat or a concave tibial insert with retention of the posterior cruciate ligament when preoperative deformity was less severe, and either a concave or a posterior-stabilized (PS) insert with resection of the posterior cruciate ligament when deformity was more pronounced. The most pronounced relative reduction (15-38%) in bone mineral density (BMD) was seen posterior to the anterior flange. There were no significant differences in relative change in BMD between flat and concave inserts. Knees operated with PS inserts had more reduction posterior to the flange than knees with concave inserts in the subgroup with more advanced preoperative deformity (23% and 38% respectively). Use of posterior stabilized insert may increase the risk of supracondylar fracture compared to concave insert in knees with advanced preoperative deformity.
  •  
8.
  • Sjöström, Lars, et al. (författare)
  • Effects of bariatric surgery on cancer incidence in obese patients in Sweden (Swedish Obese Subjects Study): a prospective, controlled intervention trial.
  • 2009
  • Ingår i: The lancet oncology. - 1474-5488. ; 10:7, s. 653-62
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Obesity is a risk factor for cancer. Intentional weight loss in the obese might protect against malignancy, but evidence is limited. To our knowledge, the Swedish Obese Subjects (SOS) study is the first intervention trial in the obese population to provide prospective, controlled cancer-incidence data. METHODS: The SOS study started in 1987 and involved 2010 obese patients (body-mass index [BMI] >or=34 kg/m(2) in men, and >or=38 kg/m(2) in women) who underwent bariatric surgery and 2037 contemporaneously matched obese controls, who received conventional treatment. While the main endpoint of SOS was overall mortality, the main outcome of this exploratory report was cancer incidence until Dec 31, 2005. Cancer follow-up rate was 99.9% and the median follow-up time was 10.9 years (range 0-18.1 years). FINDINGS: Bariatric surgery resulted in a sustained mean weight reduction of 19.9 kg (SD 15.6 kg) over 10 years, whereas the mean weight change in controls was a gain of 1.3 kg (SD 13.7 kg). The number of first-time cancers after inclusion was lower in the surgery group (n=117) than in the control group (n=169; HR 0.67, 95% CI 0.53-0.85, p=0.0009). The sex-treatment interaction p value was 0.054. In women, the number of first-time cancers after inclusion was lower in the surgery group (n=79) than in the control group (n=130; HR 0.58, 0.44-0.77; p=0.0001), whereas there was no effect of surgery in men (38 in the surgery group vs 39 in the control group; HR 0.97, 0.62-1.52; p=0.90). Similar results were obtained after exclusion of all cancer cases during the first 3 years of the intervention. INTERPRETATION: Bariatric surgery was associated with reduced cancer incidence in obese women but not in obese men. FUNDING: Swedish Research Council, Swedish Foundation for Strategic Research, Swedish Federal Government under the LUA/ALF agreement, Hoffmann La Roche, Cederoths, AstraZeneca, Sanofi-Aventis, Ethicon Endosurgery.
  •  
9.
  • Sjöström, Lars, et al. (författare)
  • Effects of bariatric surgery on mortality in Swedish obese subjects.
  • 2007
  • Ingår i: The New England journal of medicine. - 1533-4406. ; 357:8, s. 741-52
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Obesity is associated with increased mortality. Weight loss improves cardiovascular risk factors, but no prospective interventional studies have reported whether weight loss decreases overall mortality. In fact, many observational studies suggest that weight reduction is associated with increased mortality. METHODS: The prospective, controlled Swedish Obese Subjects study involved 4047 obese subjects. Of these subjects, 2010 underwent bariatric surgery (surgery group) and 2037 received conventional treatment (matched control group). We report on overall mortality during an average of 10.9 years of follow-up. At the time of the analysis (November 1, 2005), vital status was known for all but three subjects (follow-up rate, 99.9%). RESULTS: The average weight change in control subjects was less than +/-2% during the period of up to 15 years during which weights were recorded. Maximum weight losses in the surgical subgroups were observed after 1 to 2 years: gastric bypass, 32%; vertical-banded gastroplasty, 25%; and banding, 20%. After 10 years, the weight losses from baseline were stabilized at 25%, 16%, and 14%, respectively. There were 129 deaths in the control group and 101 deaths in the surgery group. The unadjusted overall hazard ratio was 0.76 in the surgery group (P=0.04), as compared with the control group, and the hazard ratio adjusted for sex, age, and risk factors was 0.71 (P=0.01). The most common causes of death were myocardial infarction (control group, 25 subjects; surgery group, 13 subjects) and cancer (control group, 47; surgery group, 29). CONCLUSIONS: Bariatric surgery for severe obesity is associated with long-term weight loss and decreased overall mortality.
  •  
10.
  • Tallheden, Tommi, 1972, et al. (författare)
  • Proliferation and differentiation potential of chondrocytes from osteoarthritic patients.
  • 2005
  • Ingår i: Arthritis research & therapy. - : Springer Science and Business Media LLC. - 1478-6362 .- 1465-9905. ; 7:3
  • Tidskriftsartikel (refereegranskat)abstract
    • Autologous chondrocyte transplantation (ACT) has been shown, in long-term follow-up studies, to be a promising treatment for the repair of isolated cartilage lesions. The method is based on an implantation of in vitro expanded chondrocytes originating from a small cartilage biopsy harvested from a non-weight-bearing area within the joint. In patients with osteoarthritis (OA), there is a need for the resurfacing of large areas, which could potentially be made by using a scaffold in combination with culture-expanded cells. As a first step towards a cell-based therapy for OA, we therefore investigated the expansion and redifferentiation potential in vitro of chondrocytes isolated from patients undergoing total knee replacement. The results demonstrate that OA chondrocytes have a good proliferation potential and are able to redifferentiate in a three-dimensional pellet model. During the redifferentiation, the OA cells expressed increasing amounts of DNA and proteoglycans, and at day 14 the cells from all donors contained type II collagen-rich matrix. The accumulation of proteoglycans was in comparable amounts to those from ACT donors, whereas total collagen was significantly lower in all of the redifferentiated OA chondrocytes. When the OA chondrocytes were loaded into a scaffold based on hyaluronic acid, they bound to the scaffold and produced cartilage-specific matrix proteins. Thus, autologous chondrocytes are a potential source for the biological treatment of OA patients but the limited collagen synthesis of the OA chondrocytes needs to be further explained.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 19
Typ av publikation
tidskriftsartikel (18)
konferensbidrag (1)
Typ av innehåll
refereegranskat (18)
övrigt vetenskapligt/konstnärligt (1)
Författare/redaktör
Carlsson, Lars, 1952 (16)
Kärrholm, Johan, 195 ... (10)
Regnér, Lars, 1955 (7)
Albrektsson, Tomas, ... (3)
Jacobsson, C. M. (3)
Macdonald, Warren, 1 ... (3)
visa fler...
Olbers, Torsten, 196 ... (2)
Gummesson, Anders, 1 ... (2)
Lönroth, Hans, 1952 (2)
Karason, Kristjan, 1 ... (2)
Lindroos, Anna-Karin ... (2)
Wedel, Hans (2)
Carlsson, Lena M S, ... (2)
Jacobson, Peter, 196 ... (2)
Sjöström, Lars (2)
Bengtsson, Calle, 19 ... (2)
Weidenhielm, L (2)
Carlsson, Björn, 195 ... (2)
Torgerson, Jarl S, 1 ... (2)
Dahlgren, Sven (2)
Näslund, Ingmar (2)
Bouchard, Claude (2)
Albrektsson, Björn E ... (2)
Stenlöf, Kaj, 1965 (2)
Narbro, Kristina, 19 ... (2)
Larsson, Bo, 1943 (2)
Karlsson, Jan (1)
Karlsson, Jón, 1953 (1)
Thomsen, Peter, 1953 (1)
Lindahl, Anders, 195 ... (1)
Stenestrand, Ulf (1)
Wallentin, Lars, 194 ... (1)
Lystig, Ted (1)
Lindbäck, Johan (1)
Gretzer, Christina, ... (1)
Lagerqvist, Bo, 1952 ... (1)
James, Stefan K., 19 ... (1)
Carlsson, Jörg (1)
Scherstén, Fredrik (1)
Peltonen, Markku, 19 ... (1)
Brantsing, Camilla (1)
Johansson, Carina B. (1)
Brittberg, Mats, 195 ... (1)
Karlsson, Jan, 1950 (1)
Peterson, Lars, 1936 (1)
Sjögren-Jansson, Eva (1)
Tallheden, Tommi, 19 ... (1)
Nilsson, Tage (1)
Weidenhielm, L. R. (1)
Sullivan, Marianne, ... (1)
visa färre...
Lärosäte
Göteborgs universitet (18)
Karolinska Institutet (3)
Umeå universitet (1)
Uppsala universitet (1)
Örebro universitet (1)
Linköpings universitet (1)
Språk
Engelska (18)
Svenska (1)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (18)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy