SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Chai Chun Ming) srt2:(2005-2009)"

Sökning: WFRF:(Chai Chun Ming) > (2005-2009)

  • Resultat 1-9 av 9
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Chai, Chun-Ming, et al. (författare)
  • Incidence of Ventricular Fibrillation during Left Coronary Arteriography in Pigs: Comparison of a Solution of the Nonionic Dimer Iodixanol with Solutions of Five Different Nonionic Monomers
  • 2008
  • Ingår i: Acta Radiologica. - : SAGE Publications. - 0284-1851 .- 1600-0455. ; 49:2, s. 150-156
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Solutions of iodine contrast media (CM) used for selective coronary arteriography (CA) should have minimal propensity to cause ventricular fibrillation (VF). Commonly used CM for CA are nonionic monomers or dimers. Purpose: To compare VF propensity of ready-to-use solutions of one nonionic dimer, iodixanol, and five nonionic monomers, iobitridol, iopamidol, iomeprol, iopromide, and ioversol. Material and Methods: Twenty milliliters of each CM was injected into the left coronary artery (LCA) through an inflated balloon catheter (0.5 ml/s) in 14 pigs; the longest period of injection was 40 s. If VF occurred before 40 s, the injection was stopped and the heart was defibrillated. After VF, there was a delay of 40 min before the next injection. Hemodynamic parameters and vector electrocardiography (VECG) were monitored. A CM with a lower frequency of VF and a longer period between start of injection and start of VF was considered to have a lower VF propensity. Results: Following 14 injections, each of the five nonionic monomers caused 14 VF, whereas iodixanol caused three VF (P<0.01). When VF occurred after iodixanol, it occurred later than after the other CM (P<0.001). Iodixanol caused less prolongation in QRS time (P<0.01) and QTc time (P<0.05) than the other CM. Prolongations in QRS and QTc times caused by CM parallel the VF propensities of the CM. Conclusion: Ready-to-use solutions of the dimer iodixanol have lower VF propensity than solutions of the five monomeric CM. This is related to the fact that the solutions of the dimer iodixanol have lower osmolality, higher viscosity, and higher concentrations of NaCl and CaCl2 than solutions of the five monomers.
  •  
2.
  • Chai, Chun-Ming, et al. (författare)
  • Signs in Vector-Electrocardiography (VECG) Predicting the Fibrillatory Propensity of Iodixanol and Mannitol Solutions After Injection Into the Left Coronary Artery of Pigs.
  • 2007
  • Ingår i: Academic Radiology. - : Elsevier BV. - 1878-4046 .- 1076-6332. ; 14:2, s. 162-177
  • Tidskriftsartikel (refereegranskat)abstract
    • Rationale and Objectives. To find signs in vector-electrocardiography (VECG) predicting the ventricular fibrillatory propensity (VF-PROP) of iodixanol and mannitol solutions after injection into the left coronary artery (LCA) of pigs. Materials and Methods. Five plasma-isotonic solutions perfused LCA: lod 320 + Na/Ca (iodixanol 320 mg I/mL, 19 mM NaCl, 0.3 mM CaCl2), lod 320 + Mann (iodixanol 320 mg I/mL, 50 mM mannitol), Mann + Na/Ca (240 mM mannitol, 19 mM NaCl, 0.3 mM CaCl2) Mann (275 mM mannitol), and Ringer (representing "physiologic electrolytes"). The first two solutions have at 37 degrees C viscosity 13 mPas and the others <1 mPas. In eight pigs, 20 mL of each solution was injected twice for 10 seconds, and in 15 pigs, each solution was injected for 11-40 seconds (0.5 mL/second) through a wedged catheter in the LCA. If ventricular fibrillation (VF) occurred, injection was stopped and heart was defibrillated. If VF did not occur, perfusion period was 40 seconds. A higher frequency of VF and a shorter period from start of injection until start of VF gave a solution a higher ranking of VF-PROP. Results. The 10-second injections caused no VF. Ringer and lod 320 + Na/Ca caused no VF after 40-second injections, whereas the other solutions caused VF. Ranking the solutions from lowest to highest VF-PROP gave: Ringer = lod 320 + Na/Ca < lod 320 + Mann < Mann + Na/Ca < Mann. Prolongation of QRS time and QTc time were the only VECG signs that showed significant differences (P <.05) between all solutions and correctly ranked the VF-PROP of all solutions in both animal groups. Conclusion. The results fit with the concept that a more physiologic electrolyte composition and a higher viscosity of a test solution will, after start of injection of that solution into LCA, delay changes in the electrolyte composition in myocardial interstitial fluid and also delay start of VF. If a plasma isotonic contrast medium (CM) with lower viscosity than that of iodixanol at 320 mgI/mL were created, we conclude that such a CM should have electrolyte composition closer to that of Ringer than present composition (19 mM NaCl and 0.3 mM CaCl2) to counteract the effects of faster diffusion of nonphysiologic electrolyte composition from the low-viscosity CM to myocardial interstitial fluid.
  •  
3.
  • Elmståhl, Barbara, et al. (författare)
  • Gadolinium contrast media are more nephrotoxic than iodine media. The importance of osmolality in direct renal artery injections
  • 2006
  • Ingår i: European Radiology. - : Springer Science and Business Media LLC. - 0938-7994 .- 1432-1084. ; 16:12, s. 2712-2720
  • Tidskriftsartikel (refereegranskat)abstract
    • A study was undertaken of the role of osmotoxicity in gadolinium (Gd) and iodine contrast media (CM) nephrotoxicity in ischemic porcine kidneys. Test solutions: mannitol iso-osmotic to 0.5 M: gadopentetate (1.96 Osm/kg H2O), 0.5 M: gadodiamide (0.78 Osm/kg H2O) and 0.5 M: iohexol (190 mg I/ml, 0.42 Osm/kg H2O). Each solution was injected [3 ml/kg body weight (BW)] into the balloon-occluded (10 min) renal artery of eight left-sided nephrectomized pigs. The plasma half-life of a glomerular filtration rate (GFR) marker was used to compare their effects on GFR 1-3 h post-injection. The median half-lives of the GFR marker after injection of gadopentetate (1,730 min) and mannitol 1.96 Osm/kg H2O (2,782 min) did not differ statistically (P = 0.28), but were significantly longer than after all other solutions (P < 0.001). There was no significant difference (P = 0.06) between gadodiamide (218 min) and mannitol 0.82 Osm/kg H2O (169 min), while there was (P = 0.03) between iohexol (181 min) and mannitol 0.43 Osm/kg H2O (148 min). The difference between gadodiamide and iohexol was significant (P = 0.01). Reduction in GFR, as a marker of nephrotoxicity, induced by gadopentetate correlated with its high osmolality, while the effect of gadodiamide and iohexol may include chemotoxicity. Iohexol molecules were less nephrotoxic than the Gd-CM molecules and contain three-times the number of attenuating atoms per molecule.
  •  
4.
  • Elmståhl, Barbara, et al. (författare)
  • Histomorphological Changes after Renal X-Ray Arteriography Using Iodine and Gadolinium Contrast Media in an Ischemic Porcine Model.
  • 2007
  • Ingår i: Acta Radiologica. - : SAGE Publications. - 1600-0455 .- 0284-1851. ; 48:10, s. 1109-1119
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Gadolinium contrast media (Gd-CM) are regarded as non-nephrotoxic or considerably less nephrotoxic than iodine contrast media (I-CM), and have therefore come to be used as a substitute for I-CM in patients with renal insufficiency in a variety of radiographic examinations. Purpose: To investigate renal histomorphological changes caused by Gd-CM in comparison with I-CM after renal X-ray arteriography in an ischemic porcine model, and to evaluate these changes in relation to the nephrotoxicity of the CM used. Material and Methods: Test solutions: gadopentetate, gadodiamide, iohexol, gadobutrol, iopromide, iodixanol, mannitol, and saline. The experiments were performed on 152 animals. Each pig was randomized to receive one test solution injected into the balloon-occluded (10 min) right renal artery. The kidneys were evaluated histomorphologically. The severity of histomorphological changes was graded subjectively: 1 = minimal, 2 = mild, 3 = moderate, and 4 = marked. Results: The main histological changes were 1) proximal tubular and glomerular necrosis, 2) hemorrhage/congestion of the cortex, medulla, and glomeruli, 3) proximal tubular vacuolation, and 4) protein-filled tubules in the cortex and medulla. Necrosis and hemorrhage/congestion were more frequent after injections with gadopentetate, mannitol solution iso-osmotic to gadopentetate, and gadobutrol compared to all other groups (P<0.001). The degree of necrosis and hemorrhage/congestion was related to the degree of impairment of renal function, but inversely related to vacuolation and tubular protein filling. Conclusion: In ischemic porcine kidneys, the histomorphological changes caused by Gd-CM are similar to those caused by I-CM. Vacuolation appears to be independent of the osmolality and viscosity of the CM, and does not seem to be an indicator of renal impairment. “High-osmolal” Gd-CM are more nephrotoxic than “low- and iso-osmolal” I-CM when compared in equal volumes of concentrations, resulting in equal X-ray attenuation.
  •  
5.
  • Elmståhl, Barbara, et al. (författare)
  • Iodixanol 320 results in better renal tolerance and radiodensity than do gadolinium-based contrast media: Arteriography in ischemic porcine kidneys
  • 2008
  • Ingår i: Radiology. - : Radiological Society of North America (RSNA). - 1527-1315 .- 0033-8419. ; 247:1, s. 88-97
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To prospectively compare nephrotoxicity and radiodensity of plasma hyperosmotic gadolinium chelates (attenuation-osmotic ratio of 1: 1) with those of plasma iso-osmotic iodine-based contrast media (attenuation-osmotic ratio of 3: 1 or 6: 1) after renal arteriography in ischemic porcine kidneys. Materials and Methods: The local animal care committee approved this study. The following contrast media were used: (a) iodixanol (150 mg of iodine per milliliter and 320 mg I/mL, 0.29 osm/kg H2O), (b) iopromide (150 mg I/mL, 0.34 osm/kg), (c) 0.5 mol/L gadodiamide (0.78 osm/kg), and (d) 1.0 mol/L gadobutrol (1.6 osm/kg). After left-sided nephrectomy, contrast media (3 mL per kilogram of body weight) were injected (20 mL/min) in a noncrossover design into the right renal artery of pigs during a 10-minute ischemic period. There were eight pigs in each group and one group for each contrast medium. We compared histomorphology, radiographic contrast medium excretion, subjective radiodensity of nephrograms (70 kVp) at the end of injection, and contrast medium plasma half-life elimination times 1-3 hours after injection. Longer elimination times resulted in lower glomerular filtration rates. Results: Gadobutrol caused extensive tubular necrosis and moderate glomerular necrosis; gadodiamide and iopromide, minimal to mild tubular necrosis; and iodixanol, no necrosis. Gadobutrol was the only contrast medium to show no sign of excretion, and its plasma half-life elimination time (median, 1103 minutes; P = .001) was significantly longer than that of other contrast agents. Gadodiamide had a significantly longer plasma half-life elimination time (median, 209 minutes; P = .01) than did iodine-based contrast media (median, 136-142 minutes). The 320 mg I/mL dose of iodixanol had the highest radiodensity, whereas gadodiamide had the lowest radiodensity. The radiodensity of the 320 mg I/mL dose of iodixanol was greater than that of the 150 mg I/mL dose of iodixanol, which was equal to the radiodensities of the 150 mg I/mL dose of iopromide and 1.0 mol/L gadobutrol, which in turn were greater than that of 0.5 mol/L gadodiamide. Conclusion: Plasma iso-osmotic iodine-based contrast media used at commercially available concentrations have superior attenuation and nephrotoxic profiles compared with equal volumes of hyperosmotic nonionic 0.5-1.0 mol/L gadolinium-based contrast media when performing renal arteriographic procedures. (c) RSNA, 2008.
  •  
6.
  • Golman, Klaes, et al. (författare)
  • Cardiac metabolism measured noninvasively by hyperpolarized (13)C MRI.
  • 2008
  • Ingår i: Magnetic Resonance in Medicine. - : Wiley. - 1522-2594 .- 0740-3194. ; 59:5, s. 1005-1013
  • Tidskriftsartikel (refereegranskat)abstract
    • Pyruvate is included in the energy production of the heart muscle and is metabolized into lactate, alanine, and CO(2) in equilibrium with HCO(3) (-). The aim of this study was to evaluate the feasibility of using (13)C hyperpolarization enhanced MRI to monitor pyruvate metabolism in the heart during an ischemic episode. The left circumflex artery of pigs (4 months, male, 29-34 kg) was occluded for 15 or 45 min followed by 2 hr of reperfusion. Pigs were examined by (13)C chemical shift imaging following intravenous injection of 1-(13)C pyruvate. (13)C chemical shift MR imaging was used in order to visualize the local concentrations of the metabolites. After a 15-min occlusion (no infarct) the bicarbonate signal level in the affected area was reduced (25-44%) compared with the normal myocardium. Alanine signal level was normal. After a 45-min occlusion (infarction) the bicarbonate signal was almost absent (0.2-11%) and the alanine signal was reduced (27-51%). Due to image-folding artifacts the data obtained for lactate were inconclusive. These studies demonstrate that cardiac metabolic imaging with hyperpolarized 1-(13)C-pyruvate is feasible. The changes in concentrations of the metabolites within a minute after injection can be detected and metabolic maps constructed. Magn Reson Med 59:1005-1013, 2008. (c) 2008 Wiley-Liss, Inc.
  •  
7.
  • Magnusson, Peter, et al. (författare)
  • Passive catheter tracking during interventional MRI using hyperpolarized 13C.
  • 2007
  • Ingår i: Magnetic Resonance in Medicine. - : Wiley. - 1522-2594 .- 0740-3194. ; 57:6, s. 1140-1147
  • Tidskriftsartikel (refereegranskat)abstract
    • nterventional procedures in MRI can be performed preclinically using active or passive catheter-tracking methods. A novel passive nonproton technique is suggested that uses a catheter filled with a hyperpolarized C-13 contrast agent. A prototype three-lumen catheter was built with two closed lumens containing a flowing hyperpolarized C-13 contrast agent. Entire-length C-13 catheter projection visualization could be performed in vivo with a catheter SNR of similar to 80, one dual projection frame per similar to 700 ms, and an in-plane resolution of 2 x 2 mm(2) while traveling through the aorta of a pig. The traveling path of the C-13 catheter was visualized after back-projection catheter reconstruction and after image fusion with an anatomical offline proton road map. Catheter length visualization was aided by an oblique planar visualization mode. The high catheter signal demonstrated, together with the entire catheter length visualization and high surrounding soft-tissue contrast, warrants further development into a real-time technique.
  •  
8.
  • Månsson, Sven, et al. (författare)
  • 13C imaging-a new diagnostic platform.
  • 2006
  • Ingår i: European Radiology. - : Springer Science and Business Media LLC. - 0938-7994 .- 1432-1084. ; 16:1, s. 57-67
  • Tidskriftsartikel (refereegranskat)abstract
    • he evolution of magnetic resonance imaging (MRI) has been astounding since the early 1980s, and a broad range of applications has emerged. To date, clinical imaging of nuclei other than protons has been precluded for reasons of sensitivity. However, with the recent development of hyperpolarization techniques, the signal from a given number of nuclei can be increased as much as 100,000 times, sufficient to enable imaging of nonproton nuclei. Technically, imaging of hyperpolarized nuclei offers several unique properties, such as complete lack of background signal and possibility for local and permanent destruction of the signal by means of radio frequency (RF) pulses. These properties allow for improved as well as new techniques within several application areas. Diagnostically, the injected compounds can visualize information about flow, perfusion, excretory function, and metabolic status. In this review article, we explain the concept of hyperpolarization and the techniques to hyperpolarize 13C. An overview of results obtained within angiography, perfusion, and catheter tracking is given, together with a discussion of the particular advantages and limitations. Finally, possible future directions of hyperpolarized 13C MRI are pointed out.
  •  
9.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-9 av 9

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy