SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Chayanun Lert)
 

Sökning: WFRF:(Chayanun Lert) > (2021) > Off-axis multilayer...

Off-axis multilayer zone plate with 16 nm × 28 nm focus for high-resolution X-ray beam induced current imaging

Soltau, Jakob (författare)
University of Göttingen
Chayanun, Lert (författare)
Lund University,Lunds universitet,NanoLund: Centre for Nanoscience,Annan verksamhet, LTH,Lunds Tekniska Högskola,Synkrotronljusfysik,Fysiska institutionen,Institutioner vid LTH,Other operations, LTH,Faculty of Engineering, LTH,Synchrotron Radiation Research,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
Lyubomirskiy, Mikhail (författare)
German Electron Synchrotron (DESY)
visa fler...
Wallentin, Jesper (författare)
Lund University,Lunds universitet,NanoLund: Centre for Nanoscience,Annan verksamhet, LTH,Lunds Tekniska Högskola,Synkrotronljusfysik,Fysiska institutionen,Institutioner vid LTH,Other operations, LTH,Faculty of Engineering, LTH,Synchrotron Radiation Research,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
Osterhoff, Markus (författare)
University of Göttingen
visa färre...
 (creator_code:org_t)
2021
2021
Engelska 10 s.
Ingår i: Journal of Synchrotron Radiation. - 0909-0495. ; 28, s. 1573-1582
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Using multilayer zone plates (MZPs) as two-dimensional optics, focal spot sizes of less than 10 nm can be achieved, as we show here with a focus of 8.4 nm × 9.6 nm, but the need for order-sorting apertures prohibits practical working distances. To overcome this issue, here an off-axis illumination of a circular MZP is introduced to trade off between working distance and focal spot size. By this, the working distance between order-sorting aperture and sample can be more than doubled. Exploiting a 2D focus of 16 nm × 28 nm, real-space 2D mapping of local electric fields and charge carrier recombination using X-ray beam induced current in a single InP nanowire is demonstrated. Simulations show that a dedicated off-axis MZP can reach sub-10 nm focusing combined with reasonable working distances and low background, which could be used for in operando imaging of composition, carrier collection and strain in nanostructured devices.

Ämnesord

NATURVETENSKAP  -- Fysik -- Atom- och molekylfysik och optik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Atom and Molecular Physics and Optics (hsv//eng)

Nyckelord

multilayer zone plates
X-ray beam induced current
X-ray imaging
X-ray optic
XBIC mapping

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy