SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Chen Shmuel) srt2:(2023)"

Sökning: WFRF:(Chen Shmuel) > (2023)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Bikdeli, Behnood, et al. (författare)
  • Bivalirudin Versus Heparin During PCI in NSTEMI : Individual Patient Data Meta-Analysis of Large Randomized Trials
  • 2023
  • Ingår i: Circulation. - : American Heart Association. - 0009-7322 .- 1524-4539. ; 148:16, s. 1207-1219
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: The benefit:risk profile of bivalirudin versus heparin anticoagulation in patients with non-ST-segment-elevation myocardial infarction undergoing percutaneous coronary intervention (PCI) is uncertain. Study-level meta-analyses lack granularity to provide conclusive answers. We sought to compare the outcomes of bivalirudin and heparin in patients with non-ST-segment-elevation myocardial infarction undergoing PCI.METHODS: We performed an individual patient data meta-analysis of patients with non-ST-segment-elevation myocardial infarction in all 5 trials that randomized >= 1000 patients with any myocardial infarction undergoing PCI to bivalirudin versus heparin (MATRIX [Minimizing Adverse Hemorrhagic Events by Transradial Access Site and Systemic Implementation of Angiox], VALIDATE-SWEDEHEART [Bivalirudin Versus Heparin in ST-Segment and Non-ST-Segment Elevation Myocardial Infarction in Patients on Modern Antiplatelet Therapy in the Swedish Web System for Enhancement and Development of Evidence-Based Care in Heart Disease Evaluated According to Recommended Therapies Registry Trial], ISAR-REACT 4 [Intracoronary Stenting and Antithrombotic Regimen: Rapid Early Action for Coronary Treatment 4], ACUITY [Acute Catheterization and Urgent Intervention Triage Strategy], and BRIGHT [Bivalirudin in Acute Myocardial Infarction vs Heparin and GPI Plus Heparin Trial]). The primary effectiveness and safety end points were 30-day all-cause mortality and serious bleeding.RESULTS: A total of 12155 patients were randomized: 6040 to bivalirudin (52.3% with a post-PCI bivalirudin infusion), and 6115 to heparin (53.2% with planned glycoprotein IIb/IIIa inhibitor use). Thirty-day mortality was not significantly different between bivalirudin and heparin (1.2% versus 1.1%; adjusted odds ratio, 1.24 [95% CI, 0.86-1.79]; P=0.25). Cardiac mortality, reinfarction, and stent thrombosis rates were also not significantly different. Bivalirudin reduced serious bleeding (both access site-related and non-access site-related) compared with heparin (3.3% versus 5.5%; adjusted odds ratio, 0.59; 95% CI, 0.48-0.72; P<0.0001). Outcomes were consistent regardless of use of a post-PCI bivalirudin infusion or routine lycoprotein IIb/IIIa inhibitor use with heparin and during 1-year follow-up.CONCLUSIONS: In patients with non-ST-segment-elevation myocardial infarction undergoing PCI, procedural anticoagulation with bivalirudin and heparin did not result in significantly different rates of mortality or ischemic events, including stent thrombosis and reinfarction. Bivalirudin reduced serious bleeding compared with heparin arising both from the access site and nonaccess sites.
  •  
2.
  • Vemulapalli, Sreekanth, et al. (författare)
  • Minimum Core Data Elements for Transcatheter Mitral Therapies : Scientific Statement by PASSION CV, HVC, and TVTR
  • 2023
  • Ingår i: JACC. - : Elsevier. - 1936-8798 .- 1876-7605. ; 16:12, s. 1437-1447
  • Forskningsöversikt (refereegranskat)abstract
    • Mitral regurgitation is the most common valvular disease and is estimated to affect over 5 million Americans. Real-world data collection contributes to safety and effectiveness evidence for the U.S. Food and Drug Administration, quality evaluation for the Centers for Medicare and Medicaid Services and hospitals, and clinical best practice research. We aimed to establish a minimum core data set in mitral interventions to promote efficient, reusable real-world data collection for all of these purposes. Two expert task forces separately evaluated and reconciled a list of candidate elements derived from: 1) 2 ongoing transcatheter mitral trials; and 2) a systemic literature review of high-impact mitral trials and U.S multicenter, multidevice registries. From 703 unique data elements considered, unanimous consensus agreement was achieved on 127 "core" data elements, with the most common reasons for exclusion from the minimum core data set being burden or difficulty in accurate assessment (41.2%), duplicative information (25.0%), and low likelihood of affecting outcomes (19.6%). After a systematic review and extensive discussions, a multilateral group of academicians, industry representatives, and regulators established and implemented into the national Society of Thoracic Surgery/ American College of Cardiology Transcatheter Valve Therapies Registry 127 interoperable, reusable core data elements to support more efficient, consistent, and informative transcatheter mitral device evidence for regulatory submissions, safety surveillance, best practice development, and hospital quality assessments.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy