SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Cognard I.) srt2:(2020-2023)"

Sökning: WFRF:(Cognard I.) > (2020-2023)

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Ajello, M., et al. (författare)
  • A gamma-ray pulsar timing array constrains the nanohertz gravitational wave background
  • 2022
  • Ingår i: Science. - : American Association for the Advancement of Science (AAAS). - 0036-8075 .- 1095-9203. ; 376:6592, s. 521-523
  • Tidskriftsartikel (refereegranskat)abstract
    • After large galaxies merge, their central supermassive black holes are expected to form binary systems. Their orbital motion should generate a gravitational wave background (GWB) at nanohertz frequencies. Searches for this background use pulsar timing arrays, which perform long-term monitoring of millisecond pulsars at radio wavelengths. We used 12.5 years of Fermi Large Area Telescope data to form a gamma-ray pulsar timing array. Results from 35 bright gamma-ray pulsars place a 95% credible limit on the GWB characteristic strain of 1.0 x 10(-14) at a frequency of 1 year(-1). The sensitivity is expected to scale with t(obs), the observing time span, as t(obs)(-13/6). This direct measurement provides an independent probe of the GWB while offering a check on radio noise models.
  •  
2.
  • Ajello, M., et al. (författare)
  • Fermi Large Area Telescope Performance after 10 Years of Operation
  • 2021
  • Ingår i: Astrophysical Journal Supplement Series. - : American Astronomical Society. - 0067-0049 .- 1538-4365. ; 256:1
  • Tidskriftsartikel (refereegranskat)abstract
    • The Large Area Telescope (LAT), the primary instrument for the Fermi Gamma-ray Space Telescope (Fermi) mission, is an imaging, wide field-of-view, high-energy gamma-ray telescope, covering the energy range from 30 MeV to more than 300 GeV. We describe the performance of the instrument at the 10 yr milestone. LAT performance remains well within the specifications defined during the planning phase, validating the design choices and supporting the compelling case to extend the duration of the Fermi mission. The details provided here will be useful when designing the next generation of high-energy gamma-ray observatories.
  •  
3.
  • Van Der Wateren, E., et al. (författare)
  • The LOFAR Tied-Array All-Sky Survey: Timing of 35 radio pulsars and an overview of the properties of the LOFAR pulsar discoveries
  • 2023
  • Ingår i: Astronomy and Astrophysics. - : EDP Sciences. - 0004-6361 .- 1432-0746. ; 669
  • Tidskriftsartikel (refereegranskat)abstract
    • The LOFAR Tied-Array All-Sky Survey (LOTAAS) is the most sensitive untargeted radio pulsar survey performed at low radio frequencies (119-151 MHz) to date and has discovered 76 new radio pulsars, including the 23.5-s pulsar J0250+5854, which up until recently was the slowest spinning radio pulsar known. In this paper, we report on the timing solutions of 35 pulsars discovered by LOTAAS, which include a nulling pulsar and a mildly recycled pulsar, and thereby complete the full timing analysis of the LOTAAS pulsar discoveries. We give an overview of the findings from the full LOTAAS sample of 76 pulsars, discussing their pulse profiles, radio spectra, and timing parameters. We found that the pulse profiles of some of the pulsars show profile variations in time or frequency, and while some pulsars show signs of scattering, a large majority display no pulse broadening. The LOTAAS discoveries have on average steeper radio spectra and longer spin periods (1.4×), as well as lower spin-down rates (3.1×) compared to the known pulsar population. We discuss the cause of these differences and attribute them to a combination of selection effects of the LOTAAS survey as well as previous pulsar surveys, though we cannot rule out that older pulsars tend to have steeper radio spectra.
  •  
4.
  • Fernandez-Sanchez, D, et al. (författare)
  • Suction force rather than aspiration flow correlates with recanalization in hard clots: an in vitro study model
  • 2021
  • Ingår i: Journal of neurointerventional surgery. - : BMJ. - 1759-8486 .- 1759-8478. ; 13:12, s. 1157-1161
  • Tidskriftsartikel (refereegranskat)abstract
    • ANA Advanced Neurovascular Access provides a novel funnel component designed to reduce clot fragmentation and facilitate retrieval in combination with stent-retrievers (SRs) in stroke patients by restricting flow and limiting clot shaving. In previous publications ANA presented excellent in vitro/in vivo efficacy data, especially with fibrin-rich hard clots. We aimed to determine the main physical property responsible for these results, namely suction force versus aspiration flow.MethodsWe evaluated in a bench model the suction force and flow generated by ANA and compared them to other neurovascular catheters combined with a SR (Solitaire). Aspiration flow was evaluated with a flow rate sensor while applying vacuum pressure with a pump. Suction force was determined using a tensile strength testing machine and a purposely designed tool that completely seals the device tip simulating complete occlusion by a hard clot. Suction force was defined as the force needed to separate the device from the clot under aspiration. All experiments were repeated five times, and mean values used for comparisons.ResultsAspiration flow increased with the inner diameter of the device: ANA 1.85±0.04 mL/s, ACE68 3.74±0.05 mL/s, and 8F-Flowgate2 5.96±0.30 mL/s (P<0.001). After introducing the SR, the flow was reduced by an average of 0.57±0.12 mL/s. Due to its larger distal surface, ANA suction force (1.69±0.40 N) was significantly higher than ACE68 (0.26±0.04 N) and 8F-Flowgate2 (0.42±0.06 N) (P<0.001). After introducing the SR, suction force variation was not relevant except for ANA that increased to 2.64±0.41 N.ConclusionDespite lower in vitro aspiration flow, the ANA design showed a substantially higher suction force than other thrombectomy devices.
  •  
5.
  • Lindgren, Erik, 1993, et al. (författare)
  • Dural arteriovenous fistulas in cerebral venous thrombosis Data from the International Cerebral Venous Thrombosis Consortium
  • 2022
  • Ingår i: European Journal of Neurology. - : Wiley. - 1351-5101 .- 1468-1331. ; 29:3, s. 761-770
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and purpose To explore the prevalence, risk factors, time correlation, characteristics and clinical outcome of dural arteriovenous fistulas (dAVFs) in a cerebral venous thrombosis (CVT) population. Methods We included patients from the International CVT Consortium registries. Diagnosis of dAVF was confirmed centrally. We assessed the prevalence and risk factors for dAVF among consecutive CVT patients and investigated its impact on clinical outcome using logistic regression analysis. We defined poor outcome as modified Rankin Scale score 3-6 at last follow-up. Results dAVF was confirmed in 29/1218 (2.4%) consecutive CVT patients. The median (interquartile range [IQR]) follow-up time was 8 (5-23) months. Patients with dAVF were older (median [IQR] 53 [44-61] vs. 41 [29-53] years; p < 0.001), more frequently male (69% vs. 33%; p < 0.001), more often had chronic clinical CVT onset (>30 days: 39% vs. 7%; p < 0.001) and sigmoid sinus thrombosis (86% vs. 51%; p < 0.001), and less frequently had parenchymal lesions (31% vs. 55%; p = 0.013) at baseline imaging. Clinical outcome at last follow-up did not differ between patients with and without dAVF. Additionally, five patients were confirmed with dAVF from non-consecutive CVT cohorts. Among all patients with CVT and dAVF, 17/34 (50%) had multiple fistulas and 23/34 (68%) had cortical venous drainage. Of 34 patients with dAVF with 36 separate CVT events, 3/36 fistulas (8%) were diagnosed prior to, 20/36 (56%) simultaneously and 13/36 after (36%, median 115 [IQR 38-337] days) diagnosis of CVT. Conclusions Dural arteriovenous fistulas occur in at least 2% of CVT patients and are associated with chronic CVT onset, older age and male sex. Most CVT-related dAVFs are detected simultaneously or subsequently to diagnosis of CVT.
  •  
6.
  • Sanchez, S, et al. (författare)
  • Preclinical evaluation of the ANCD thrombectomy device: safety and efficacy in a swine clot model
  • 2020
  • Ingår i: Journal of neurointerventional surgery. - : BMJ. - 1759-8486 .- 1759-8478. ; 12:10, s. 1008-1013
  • Tidskriftsartikel (refereegranskat)abstract
    • The Advanced Thrombectomy System (ANCD) provides a new funnel component designed to reduce clot fragmentation and facilitate retrieval in patients with stroke by locally restricting flow, allowing distal aspiration in combination with a stent retriever (SR).ObjectiveTo evaluate the preclinical efficacy and safety of the ANCD in a swine clot model.MethodsSoft and firm clots were implanted in the lingual and cervical arteries of 11 swine to obtain Thrombolysis in Cerebral Infarction (TICI) 0 blood flow. Mechanical thrombectomy was performed with either a balloon guide catheter+Solitaire 2 stent retriever (BGC+SR, n=13) or ANCD+SR (n=13). TICI flow was evaluated and successful revascularization was defined as TICI 3 (normal perfusion). To characterize safety, a total of 3 passes were performed in each vessel independent of recanalization. Tissues were explanted for histopathological analysis after 3 and 30 days, respectively.ResultsFirst pass reperfusion rates were ANCD+SR: 69% and BGC+SR: 46%. Reperfusion increased after the third pass in both groups (ANCD+SR: 100%, vs BGC+SR: 77%). Recanalization was achieved after an average of 1.4 and 1.9 passes in ANCD+SR and BGC+SR (p=0.095), respectively. Vessel injury was comparable in both groups; endothelial loss at 3 days was the most common injury seen (ANCD+SR: 1.78±1.22; BGC+SR: 2.03±1.20; p=0.73), while other histopathological markers were absent or minimal. Tissues downstream from targeted vessels also showed absence or minimal lesions across both groups.ConclusionsResults in a swine clot model support the high efficacy of the ANCD+SR without causing clinically significant vessel injury potentially related to the new funnel component.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy