SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Collaboration A. T. L. A. S.) srt2:(2005-2009)"

Sökning: WFRF:(Collaboration A. T. L. A. S.) > (2005-2009)

  • Resultat 1-7 av 7
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Abbasi, R, et al. (författare)
  • FIRST NEUTRINO POINT-SOURCE RESULTS FROM THE 22 STRING ICECUBE DETECTOR
  • 2009
  • Ingår i: Astrophysical Journal Letters. - 2041-8205. ; 701, s. L47-L51
  • Tidskriftsartikel (refereegranskat)abstract
    • We present new results of searches for neutrino point sources in the northern sky, using data recorded in 2007-2008 with 22 strings of the IceCube detector (approximately one-fourth of the planned total) and 275.7 days of live time. The final sample of 5114 neutrino candidate events agrees well with the expected background of atmospheric muon neutrinos and a small component of atmospheric muons. No evidence of a point source is found, with the most significant excess of events in the sky at 2.2 sigma after accounting for all trials. The average upper limit over the northern sky for point sources of muon-neutrinos with E-2 spectrum is E-2 Phi(v mu) < 1.4 x 10(-11) TeV cm(-2) s(-1), in the energy range from 3 TeV to 3 PeV, improving the previous best average upper limit by the AMANDA-II detector by a factor of 2.
  •  
2.
  • Achterberg, A., et al. (författare)
  • Detection of atmospheric muon neutrinos with the IceCube 9-string detector
  • 2007
  • Ingår i: Physical Review D - Particles, Fields, Gravitation and Cosmology. - 1550-7998. ; 76:2, s. 027101-
  • Tidskriftsartikel (refereegranskat)abstract
    • The IceCube neutrino detector is a cubic kilometer TeV to PeV neutrino detector under construction at the geographic South Pole. The dominant population of neutrinos detected in IceCube is due to meson decay in cosmic-ray air showers. These atmospheric neutrinos are relatively well understood and serve as a calibration and verification tool for the new detector. In 2006, the detector was approximately 10% completed, and we report on data acquired from the detector in this configuration. We observe an atmospheric neutrino signal consistent with expectations, demonstrating that the IceCube detector is capable of identifying neutrino events. In the first 137.4 days of live time, 234 neutrino candidates were selected with an expectation of 211 +/- 76.1(syst)+/- 14.5(stat) events from atmospheric neutrinos.
  •  
3.
  • Achterberg, A., et al. (författare)
  • Multiyear search for a diffuse flux of muon neutrinos with AMANDA-II
  • 2007
  • Ingår i: Physical Review D - Particles, Fields, Gravitation and Cosmology. - 1550-7998. ; 76:4, s. 042008-
  • Tidskriftsartikel (refereegranskat)abstract
    • A search for TeV-PeV muon neutrinos from unresolved sources was performed on AMANDA-II data collected between 2000 and 2003 with an equivalent live time of 807 days. This diffuse analysis sought to find an extraterrestrial neutrino flux from sources with nonthermal components. The signal is expected to have a harder spectrum than the atmospheric muon and neutrino backgrounds. Since no excess of events was seen in the data over the expected background, an upper limit of E-2 Phi(90%C.L.)< 7.4x10(-8) GeV cm(-2) s(-1) sr(-1) is placed on the diffuse flux of muon neutrinos with a Phi proportional to E-2 spectrum in the energy range 16 TeV to 2.5 PeV. This is currently the most sensitive Phi proportional to E-2 diffuse astrophysical neutrino limit. We also set upper limits for astrophysical and prompt neutrino models, all of which have spectra different from Phi proportional to E-2.
  •  
4.
  • Emerging Risk Factors, Collaboration, et al. (författare)
  • The Emerging Risk Factors Collaboration: analysis of individual data on lipid, inflammatory and other markers in over 1.1 million participants in 104 prospective studies of cardiovascular diseases
  • 2007
  • Ingår i: Eur J Epidemiol. - 0393-2990. ; 22:12, s. 839-69
  • Tidskriftsartikel (refereegranskat)abstract
    • Many long-term prospective studies have reported on associations of cardiovascular diseases with circulating lipid markers and/or inflammatory markers. Studies have not, however, generally been designed to provide reliable estimates under different circumstances and to correct for within-person variability. The Emerging Risk Factors Collaboration has established a central database on over 1.1 million participants from 104 prospective population-based studies, in which subsets have information on lipid and inflammatory markers, other characteristics, as well as major cardiovascular morbidity and cause-specific mortality. Information on repeat measurements on relevant characteristics has been collected in approximately 340,000 participants to enable estimation of and correction for within-person variability. Re-analysis of individual data will yield up to approximately 69,000 incident fatal or nonfatal first ever major cardiovascular outcomes recorded during about 11.7 million person years at risk. The primary analyses will involve age-specific regression models in people without known baseline cardiovascular disease in relation to fatal or nonfatal first ever coronary heart disease outcomes. This initiative will characterize more precisely and in greater detail than has previously been possible the shape and strength of the age- and sex-specific associations of several lipid and inflammatory markers with incident coronary heart disease outcomes (and, secondarily, with other incident cardiovascular outcomes) under a wide range of circumstances. It will, therefore, help to determine to what extent such associations are independent from possible confounding factors and to what extent such markers (separately and in combination) provide incremental predictive value.
  •  
5.
  •  
6.
  •  
7.
  • Lorente, A. Sanchez, et al. (författare)
  • Performance of HPGe detectors in high magnetic fields
  • 2007
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 573:3, s. 410-417
  • Tidskriftsartikel (refereegranskat)abstract
    • A new generation of high-resolution hypernuclear gamma-spectroscopy experiments with high-purity germanium detectors (HPGe) are presently designed at the FINUDA spectrometer at DA Phi NE, the Frascati phi-factory, and at (P) over bar ANDA, the (p) over barp hadron spectrometer at the future FAIR facility. Both, the FINUDA and (P) over bar ANDA spectrometers are built around the target region covering a large solid angle. To maximise the detection efficiency the HPGe detectors have to be located near the target, and therefore they have to be operated in strong magnetic fields (B approximate to I T). The performance of HPGe detectors in such an environment has not been well investigated so far. In the present work VEGA and EUROBALL Cluster HPGe detectors were tested in the field provided by the ALADiN magnet at GSI. No significant degradation of the energy resolution was found, and a change in the rise time distribution of the pulses from preamplifiers was observed. A correlation between rise time and pulse height was observed and is used to correct the measured energy, recovering the energy resolution almost completely. Moreover, no problems in the electronics due to the magnetic field were observed.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-7 av 7

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy