SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Cui Liying) srt2:(2020)"

Sökning: WFRF:(Cui Liying) > (2020)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Cohen, David, 1977, et al. (författare)
  • Exponential integrators for stochastic Maxwell's equations driven by Itô noise
  • 2020
  • Ingår i: Journal of Computational Physics. - : Elsevier BV. - 1090-2716 .- 0021-9991. ; 410
  • Tidskriftsartikel (refereegranskat)abstract
    • This article presents explicit exponential integrators for stochastic Maxwell's equations driven by both multiplicative and additive noises. By utilizing the regularity estimate of the mild solution, we first prove that the strong order of the numerical approximation is [Formula presented] for general multiplicative noise. Combining a proper decomposition with the stochastic Fubini's theorem, the strong order of the proposed scheme is shown to be 1 for additive noise. Moreover, for linear stochastic Maxwell's equation with additive noise, the proposed time integrator is shown to preserve exactly the symplectic structure, the evolution of the energy as well as the evolution of the divergence in the sense of expectation. Several numerical experiments are presented in order to verify our theoretical findings.
  •  
2.
  • Tankisi, Hatice, et al. (författare)
  • Standards of instrumentation of EMG
  • 2020
  • Ingår i: Clinical Neurophysiology. - : Elsevier. - 1388-2457 .- 1872-8952. ; 131:1, s. 243-258
  • Forskningsöversikt (refereegranskat)abstract
    • Standardization of Electromyography (EMG) instrumentation is of particular importance to ensure high quality recordings. This consensus report on "Standards of Instrumentation of EMG" is an update and extension of the earlier IFCN Guidelines published in 1999. First, a panel of experts in different fields from different geographical distributions was invited to submit a section on their particular interest and expertise. Then, the merged document was circulated for comments and edits until a consensus emerged. The first sections in this document cover technical aspects such as instrumentation, EMG hardware and software including amplifiers and filters, digital signal analysis and instrumentation settings. Other sections cover the topics such as temporary storage, trigger and delay line, averaging, electrode types, stimulation techniques for optimal and standardised EMG examinations, and the artefacts electromyographers may face and safety rules they should follow. Finally, storage of data and databases, report generators and external communication are summarized. (C) 2019 The Author(s). Published by Elsevier B.V. on behalf of International Federation of Clinical Neurophysiology.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy