SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Daouacher Georgios 1978 ) srt2:(2016)"

Sökning: WFRF:(Daouacher Georgios 1978 ) > (2016)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Daouacher, Georgios, 1978-, et al. (författare)
  • Laparoscopic extended pelvic lymph node (LN) dissection as validation of the performance of [(11) C]-acetate positron emission tomography/computer tomography in the detection of LN metastasis in intermediate- and high-risk prostate cancer
  • 2016
  • Ingår i: BJU International. - : Blackwell Publishing. - 1464-4096 .- 1464-410X. ; 118:1, s. 77-83
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVES: To evaluate the accuracy of the radiopharmaceutical [(11) C]-acetate combined with positron emission tomography/computer tomography (acetate-PET/CT) in lymph node (LN) staging in newly diagnosed prostate cancer cases. A second aim was to evaluate the potential discriminative properties of acetate-PET/CT in clinical routine.PATIENTS AND METHODS: In a prospective comparative study, from July 2010 to June 2013, 53 men with newly histologically diagnosed intermediate- or high-risk prostate cancer underwent acetate-PET/CT investigation at one regional centre before laparoscopic extended pelvic LN dissection (ePLND) at one referral centre. The sensitivity, specificity and accuracy of acetate-PET/CT were calculated. Comparisons were made between true-positive and false-negative PET/CT cases to identify differences in the clinical parameters: PSA level, Gleason status, lymph metastasis burden and size, calculated risk of LN involvement, and curative treatment decisions.RESULTS: In all, 26 patients had surgically/histologically confirmed LN metastasis (LN+). Acetate-PET/CT was true positive in 10 patients, false positive in one, false negative in 16, and true negative in 26. The individual sensitivity was 38%, specificity 96%, and accuracy 68%. The acetate-PET/CT positive cases had significantly more involved LNs (mean 7.9 vs 2.4, P < 0.001) with larger cancer diameters (14.1 vs 4.9 mm, P = 0.001) and fewer eventually had treatment with curative intent (40% vs 94%, P <0.005), although we lack long-term outcome data.CONCLUSION: Acetate-PET/CT has too low a sensitivity for routine LN staging but the specificity is high. The acetate-PET/CT positive cases have a very high burden of LN spread.
  •  
2.
  • von Below, Catrin, et al. (författare)
  • Validation of 3 T MRI including diffusion-weighted imaging for nodal staging of newly diagnosed intermediate- and high-risk prostate cancer
  • 2016
  • Ingår i: Clinical Radiology. - : Saunders Elsevier. - 0009-9260 .- 1365-229X. ; 71:4, s. 328-334
  • Tidskriftsartikel (refereegranskat)abstract
    • AIM: To prospectively validate 3 T magnetic resonance imaging (MRI) including diffusion-weighted imaging (DWI) for preoperative lymph node (LN) staging in a clinical setting, in intermediate- and high-risk prostate cancer (PCa) patients using laparoscopic extended LN dissection (ePLND) as the reference standard.MATERIALS AND METHODS: Between August 2011 and May 2013, 40 newly diagnosed intermediate and high-risk PCa patients underwent preoperative LN staging with 3 T MRI DWI using histopathology of ePLND as the reference standard. The sensitivity, specificity, and accuracy of MRI DWI were calculated. A subgroup analysis of proven LN-positive patients was made to investigate differences in PSA, Gleason score, number, and size of LN metastases, estimated risk of LN involvement, and if curative treatment was indicated, between the true-positive and the false-negative groups.RESULTS: A total of 728 LN were harvested from six anatomical regions per patient (external, obturator, internal) with a mean number of 18 LNs per patient (range 11-40). Twenty patients had histologically proven LN-positive disease. MRI DWI was true positive in 11 patients, false negative in nine patients, false positive in two patients, and true negative in 18 patients, resulting in 90% specificity, 55% sensitivity, and 72.5% accuracy. The true-positive patients had significantly more involved LNs (mean 6.9 versus 2.7, p=0.017), with larger diameter (mean 12.3 versus 5.2 mm, p=0.048) and fewer were treated with curative intent (six versus nine, p=0.03), compared with the false-negative group.CONCLUSION: MRI DWI LN staging has a low sensitivity but high specificity. The true-positive patients have a considerably higher burden of LN metastases compared to false-negative patients.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy