SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Darling J.) srt2:(2006-2009)"

Sökning: WFRF:(Darling J.) > (2006-2009)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Schael, S, et al. (författare)
  • Precision electroweak measurements on the Z resonance
  • 2006
  • Ingår i: Physics Reports. - : Elsevier BV. - 0370-1573 .- 1873-6270. ; 427:5-6, s. 257-454
  • Forskningsöversikt (refereegranskat)abstract
    • We report on the final electroweak measurements performed with data taken at the Z resonance by the experiments operating at the electron-positron colliders SLC and LEP. The data consist of 17 million Z decays accumulated by the ALEPH, DELPHI, L3 and OPAL experiments at LEP, and 600 thousand Z decays by the SLID experiment using a polarised beam at SLC. The measurements include cross-sections, forward-backward asymmetries and polarised asymmetries. The mass and width of the Z boson, m(Z) and Gamma(Z), and its couplings to fermions, for example the p parameter and the effective electroweak mixing angle for leptons, are precisely measured: m(Z) = 91.1875 +/- 0.0021 GeV, Gamma(Z) = 2.4952 +/- 0.0023 GeV, rho(l) = 1.0050 +/- 0.0010, sin(2)theta(eff)(lept) = 0.23153 +/- 0.00016. The number of light neutrino species is determined to be 2.9840 +/- 0.0082, in agreement with the three observed generations of fundamental fermions. The results are compared to the predictions of the Standard Model (SM). At the Z-pole, electroweak radiative corrections beyond the running of the QED and QCD coupling constants are observed with a significance of five standard deviations, and in agreement with the Standard Model. Of the many Z-pole measurements, the forward-backward asymmetry in b-quark production shows the largest difference with respect to its SM expectation, at the level of 2.8 standard deviations. Through radiative corrections evaluated in the framework of the Standard Model, the Z-pole data are also used to predict the mass of the top quark, m(t) = 173(+10)(+13) GeV, and the mass of the W boson, m(W) = 80.363 +/- 0.032 GeV. These indirect constraints are compared to the direct measurements, providing a stringent test of the SM. Using in addition the direct measurements of m(t) and m(W), the mass of the as yet unobserved SM Higgs boson is predicted with a relative uncertainty of about 50% and found to be less than 285 GeV at 95% confidence level. (c) 2006 Elsevier B.V. All rights reserved.
  •  
2.
  • Rich, Rebecca L., et al. (författare)
  • A global benchmark study using affinity-based biosensors
  • 2009
  • Ingår i: Analytical Biochemistry. - : Elsevier BV. - 0003-2697 .- 1096-0309. ; 386:2, s. 194-216
  • Tidskriftsartikel (refereegranskat)abstract
    • To explore the variability in biosensor studies, 150 participants from 20 countries were given the same protein samples and asked to determine kinetic rate constants for the interaction. We chose a protein system that was amenable to analysis using different biosensor platforms as well as by users of different expertise levels. The two proteins (a 50-kDa Fab and a 60-kDa glutathione S-transferase [GST] antigen) form a relatively high-affinity complex, so participants needed to optimize several experimental parameters, including ligand immobilization and regeneration conditions as well as analyte concentrations and injection/dissociation times. Although most participants collected binding responses that could be fit to yield kinetic parameters, the quality of a few data sets could have been improved by optimizing the assay design. Once these outliers were removed, the average reported affinity across the remaining panel of participants was 620 pM with a standard deviation of 980 pM. These results demonstrate that when this biosensor assay was designed and executed appropriately, the reported rate constants were consistent, and independent of which protein was immobilized and which biosensor was used.
  •  
3.
  • Houde, Magali, et al. (författare)
  • POLYBROMINATED DIPHENYL ETHERS AND THEIR HYDROXYLATED ANALOGS IN PLASMA OF BOTTLENOSE DOLPHINS (TURSIOPS TRUNCATUS) FROM THE UNITED STATES EAST COAST.
  • 2009
  • Ingår i: Environmental Toxicology and Chemistry. - : Wiley. - 0730-7268 .- 1552-8618. ; 28:10, s. 2061-2068
  • Tidskriftsartikel (refereegranskat)abstract
    • Polybrominated diphenyl ethers (PBDEs) and hydroxylated-PBDEs (OH-PBDE) were determined in plasma of free-ranging bottlenose dolphins (Tursiops truncatus) from Charleston (CHS), South Carolina, and the Indian River Lagoon (IRL), Florida, US. Significantly lower sum (Sigma) of PBDE concentrations (sum of 12 congeners) were found in animals from the IRL [arithmetic mean: 5.454.63 ng/g wet weight (ww)] compared to CHS (3040 ng/g ww). BDE-47 was the predominant PBDE in dolphins from the IRL (50% of the SigmaPBDEs) and CHS (58%). SigmaPBDE concentrations in plasma of dolphins were negatively correlated with age at both locations. Fifteen and sixteen individual OH-PBDE congeners could be quantified in plasma of dolphins from IRL and CHS, respectively. Similar to SigmaPBDE, mean SigmaOH-PBDE concentrations were significantly higher in plasma of dolphins at CHS (1150708 pg/g ww) compared to IRL (624393 pg/g ww). The predominant congener at both locations was 6-OH-PBDE 47 (IRL: 384319 pg/g ww; CHS: 541344 pg/g ww) representing 61.5% of total SigmaOH-PBDE at IRL and 47.0% at CHS. Concentrations of SigmaOH-PBDEs were weakly negatively correlated with age in dolphins from both locations (P<0.05; IRL, R2=0.048; CHS, R2=0.021). In addition to the OH-PBDE congeners identified with technical standards, eight and four unidentified OH-PBDEs were detected and quantified respectively in animals from CHS (sum of unidentified OH-PBDEs=1.350.90 pg/g ww) and IRL (0.730.40 pg/g ww). Our results suggest that, unlike OH-PCBs, OH-PBDEs in bottlenose dolphins are minor products in plasma relative to SigmaPBDEs and a significant proportion may be a consequence of the dietary uptake of naturally produced methoxylated- and OH-PBDEs.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy