SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Davis J) srt2:(1990-1994)"

Sökning: WFRF:(Davis J) > (1990-1994)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Davis, J.L., et al. (författare)
  • Ground-based measurement of gradients in the “wet” radio refractivity of air
  • 1993
  • Ingår i: Radio Science. - 0048-6604 .- 1944-799X. ; 28:6, s. 1003-1018
  • Tidskriftsartikel (refereegranskat)abstract
    • We have used a ground-based microwave radiometer, known as a water vapor radiometer, to investigate the local spatial and temporal variation of the wet propagation delay for a site on the west coast of Sweden. The data were obtained from a wide range of azimuths and from elevation angles greater than 23.6-degrees (air mass 2.5). Visual inspection of the data suggested a simple ‘'cosine azimuth” variation, implying that a first-order gradient model was required. This model was adequate for short time spans up to approximately 15 min, but significant temporal variations in the gradient suggested to us that we include gradient rate terms. The resulting six-parameter model has proven adequate (rms delay residual approximately 1 mm) for up to 30 min of data. Assuming a simple exponential profile for the wet refractivity gradient, the estimated gradient parameters imply average surface wet-refractivity horizontal gradients of order of 0.1-1 N km-1. These gradients are larger, by 1-2 orders of magnitude, than gradients determined by others by averaging over long (approximately 100-km) distances. This result implies that for applications that are sensitive to local gradients, such as wet propagation-delay models for radio-interferometric geodetic studies, the use of meteorological data from widely spread stations may be inadequate. The gradient model presented here is inadequate for times longer than about 30 min. even if no gradients are present, because of the complicated stochastic like temporal behavior of the wet atmosphere. When gradients are present, they can change magnitude by approximately 50% over 10-15 min. Nevertheless, our ability to fit the radiometer data implies that on timescales 23.6-degrees, the local structure of the wet atmosphere can be described with a simple model. (The model is not limited to this range of elevation angles in principle.) The estimated gradient and gradient rate vectors have preferred directions, which indicates a prevailing structure in the three-dimensional temperature and humidity fields, possibly related to systematic behavior in large-scale weather systems and/or the local air-land-sea interaction at this site.
  •  
2.
  • Davis, N T, et al. (författare)
  • Crustacean cardioactive peptide-immunoreactive neurons in the hawkmoth Manduca sexta and changes in their immunoreactivity during postembryonic development.
  • 1993
  • Ingår i: Journal of Comparative Neurology. - : Wiley. - 0021-9967 .- 1096-9861. ; 338:4, s. 612-27
  • Tidskriftsartikel (refereegranskat)abstract
    • An antiserum against crustacean cardioactive peptide was used, in indirect immunocytochemistry on whole-mounts and Vibratome sections, to map immunoreactive neurons at various stages of postembryonic development of the hawkmoth Manduca sexta. About 90 immunoreactive neurons were identified. Many of these cells are immunoreactive at hatching and persist into the adult stage; others become immunoreactive late in postembryonic development. During adult development, transient immunoreactivity is expressed in several cells in the subesophageal and thoracic ganglia. Two sets of immunoreactive neurons are found in the protocerebrum of larvae, but only one of these sets persists into the adult stage. Paired lateral interneurons and neurosecretory neurons are segmentally repeated in the abdominal ganglia and are present from the first larval stage to the adult; the abdominal interneurons project contralaterally to arborizations in adjacent ganglia, and some ascend to tritocerebral arborizations. The abdominal neurosecretory cells, which correspond to a pair of cells reported to contain bursicon, project posteriorly to neurohemal release organs. Motor neurons of dorsal external oblique abdominal muscles become immunoreactive in the fourth larval stage. Paired median neurosecretory cells of abdominal ganglia become immunoreactive during the fifth larval stage. The immunoreactive median and lateral abdominal neurosecretory cells are a subset of a group of cells known to contain cardioactive peptides. Paired lateral neurosecretory cells of the subesophageal ganglion become immunoreactive during pupation and project to the corpora cardiaca and aorta of the adult. Many of the neurons identified here are comparable to crustacean cardioactive peptide-immunoreactive cells described previously in locusts and the mealworm beetle.
  •  
3.
  • Elgered, Gunnar, 1955, et al. (författare)
  • Geodesy by Radio Interferometry: Water Vapor Radiometry for Estimation of the Wet Delay
  • 1991
  • Ingår i: Journal of Geophysical Research. - 0148-0227 .- 2156-2202. ; 96:B4, s. 6541-6555
  • Tidskriftsartikel (refereegranskat)abstract
    • An important source of error in very-long-baseline interferometry (VLBI) estimates of baseline length is unmodeled variations of the refractivity of the neutral atmosphere along the propagation path of the radio signals. We present and discuss the method of using data from a water vapor radiometer (WVR) to correct for the propagation delay caused by atmospheric water vapor, the major cause of these variations. Data from different WVRs are compared with estimated propagation delays obtained by Kalman filtering of the VLBI data themselves. The consequences of using either WVR data or Kalman filtering to correct for atmospheric propagation delay at the Onsala VLBI site are investigated by studying the repeatability of estimated baseline lengths from Onsala to several other sites. The lengths of the baselines range from 919 to 7941 km. The repeatability obtained for baseline length estimates shows that the methods of water vapor radiometry and Kalman filtering offer comparable accuracies when applied to VLBI observations obtained in the climate of the Swedish west coast. For the most frequently measured baseline in this study, the use of WVR data yielded a 13% smaller weighted-root-mean-square (WRMS) scatter of the baseline length estimates compared to the use of a Kalman filter. It is also clear that the “best” minimum elevation angle for VLBI observations depends on the accuracy of the determinations of the total propagation delay to be used, since the error in this delay increases with increasing air mass. For use of WVR data along with accurate determinations of total surface pressure, the best minimum is about 20 degrees; for use of a model for the wet delay based on the humidity and temperature at the ground, the best minimum is about 35 degrees.
  •  
4.
  • Lindgren, Owe, et al. (författare)
  • Non-destructive wood density distribution measurements using computed tomography
  • 1991
  • Ingår i: European Journal of Wood and Wood Products. - 0018-3768 .- 1436-736X. ; 50:7-8, s. 295-299
  • Tidskriftsartikel (refereegranskat)abstract
    • Two computed tomography scanners have been used to acquire density profiles from five wooden test pieces. These test pieces had annual growth ring widths varying between about 0.6 mm and 3.5 mm. The two scanners employed were a medical scanner, a GE 9800 Quick scan system, and a purpose built microscanner constructed around a Rigaku D-Max II diffractometer. The results demonstrated that the annual growth rings could be resolved and density measurements could be reliably determined using the microscanner when the annual growth rings were about 0.9 mm or greater in width. The medical scanner could not satisfactorily measure density in carlywood or latewood resions even in samples where the annual growth ring width was of the order of 3.5 mm. A small difference in density measurements could be observed between the two scanners for the same specimens. The difference is attributed to calibration differences, the reconstruction algorithms used and the different geometries of the two systems; particularly in relation to the detector apertures. The larger detector size in the medical system results in too high or too low density values in the carlywood or the latewood respectively due to spatial averaging. However, the medical scanner provides satisfactory density accuracy in specimens where the density is very uniform or as long as measured areas include both carlywood and latewood. An accuracy of ±2-6 kg/m3 at 95% confidence level can then be expected.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy