SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(De Luca V.) srt2:(2010-2014)"

Sökning: WFRF:(De Luca V.) > (2010-2014)

  • Resultat 1-10 av 28
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Acharya, B. S., et al. (författare)
  • Introducing the CTA concept
  • 2013
  • Ingår i: Astroparticle physics. - : Elsevier BV. - 0927-6505 .- 1873-2852. ; 43, s. 3-18
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • The Cherenkov Telescope Array (CTA) is a new observatory for very high-energy (VHE) gamma rays. CTA has ambitions science goals, for which it is necessary to achieve full-sky coverage, to improve the sensitivity by about an order of magnitude, to span about four decades of energy, from a few tens of GeV to above 100 TeV with enhanced angular and energy resolutions over existing VHE gamma-ray observatories. An international collaboration has formed with more than 1000 members from 27 countries in Europe, Asia, Africa and North and South America. In 2010 the CTA Consortium completed a Design Study and started a three-year Preparatory Phase which leads to production readiness of CTA in 2014. In this paper we introduce the science goals and the concept of CTA, and provide an overview of the project. (C) 2013 Elsevier B.V. All rights reserved.
  •  
2.
  • Aaltonen, T., et al. (författare)
  • Combination of CDF and D0 W-Boson mass measurements
  • 2013
  • Ingår i: Physical Review D. - 1550-7998 .- 1550-2368. ; 88:5, s. 052018-
  • Tidskriftsartikel (refereegranskat)abstract
    • We summarize and combine direct measurements of the mass of the W boson in root s = 1.96 TeV proton-antiproton collision data collected by CDF and D0 experiments at the Fermilab Tevatron Collider. Earlier measurements from CDF and D0 are combined with the two latest, more precise measurements: a CDF measurement in the electron and muon channels using data corresponding to 2.2 fb(-1) of integrated luminosity, and a D0 measurement in the electron channel using data corresponding to 4.3 fb(-1) of integrated luminosity. The resulting Tevatron average for the mass of the W boson is M-W = 80387 +/- 16 MeV. Including measurements obtained in electron-positron collisions at LEP yields the most precise value of M-W = 80385 +/- 15 MeV.
  •  
3.
  • Aaltonen, T., et al. (författare)
  • Combination of measurements of the top-quark pair production cross section from the Tevatron Collider
  • 2014
  • Ingår i: Physical Review D. - 1550-7998 .- 1550-2368. ; 89:7
  • Tidskriftsartikel (refereegranskat)abstract
    • We combine six measurements of the inclusive top-quark pair (t(sic)) production cross section (sigma(t)(sic)) from data collected with the CDF and D0 detectors at the Fermilab Tevatron with proton-antiproton collisions at root s = 1.96 TeV. The data correspond to integrated luminosities of up to 8.8 fb(-1). We obtain a value of sigma tt = 7.60 +/- 0.41 pb for a top-quark mass of m(t) = 172.5 GeV. The contributions to the uncertainty are 0.20 pb from statistical sources, 0.29 pb from systematic sources, and 0.21 pb from the uncertainty on the integrated luminosity. The result is in good agreement with the standard model expectation of 7.35(-0.33)(+0.28) pb at next-to-next-to-leading order and next-to-next-to leading logarithms in perturbative QCD.
  •  
4.
  • Aaltonen, T., et al. (författare)
  • Observation of s-Channel Production of Single Top Quarks at the Tevatron
  • 2014
  • Ingår i: Physical Review Letters. - 0031-9007 .- 1079-7114. ; 112:23
  • Tidskriftsartikel (refereegranskat)abstract
    • We report the first observation of single-top-quark production in the s channel through the combination of the CDF and D0 measurements of the cross section in proton-antiproton collisions at a center-of-mass energy of 1.96 TeV. The data correspond to total integrated luminosities of up to 9.7 fb(-1) per experiment. The measured cross section is sigma(s) = 1.29(-0.24)(+0.26) pb. The probability of observing a statistical fluctuation of the background to a cross section of the observed size or larger is 1.8 x 10(-10), corresponding to a significance of 6.3 standard deviations for the presence of an s-channel contribution to the production of single-top quarks.
  •  
5.
  •  
6.
  • Klionsky, Daniel J., et al. (författare)
  • Guidelines for the use and interpretation of assays for monitoring autophagy
  • 2012
  • Ingår i: Autophagy. - : Informa UK Limited. - 1554-8635 .- 1554-8627. ; 8:4, s. 445-544
  • Forskningsöversikt (refereegranskat)abstract
    • In 2008 we published the first set of guidelines for standardizing research in autophagy. Since then, research on this topic has continued to accelerate, and many new scientists have entered the field. Our knowledge base and relevant new technologies have also been expanding. Accordingly, it is important to update these guidelines for monitoring autophagy in different organisms. Various reviews have described the range of assays that have been used for this purpose. Nevertheless, there continues to be confusion regarding acceptable methods to measure autophagy, especially in multicellular eukaryotes. A key point that needs to be emphasized is that there is a difference between measurements that monitor the numbers or volume of autophagic elements (e.g., autophagosomes or autolysosomes) at any stage of the autophagic process vs. those that measure flux through the autophagy pathway (i.e., the complete process); thus, a block in macroautophagy that results in autophagosome accumulation needs to be differentiated from stimuli that result in increased autophagic activity, defined as increased autophagy induction coupled with increased delivery to, and degradation within, lysosomes (in most higher eukaryotes and some protists such as Dictyostelium) or the vacuole (in plants and fungi). In other words, it is especially important that investigators new to the field understand that the appearance of more autophagosomes does not necessarily equate with more autophagy. In fact, in many cases, autophagosomes accumulate because of a block in trafficking to lysosomes without a concomitant change in autophagosome biogenesis, whereas an increase in autolysosomes may reflect a reduction in degradative activity. Here, we present a set of guidelines for the selection and interpretation of methods for use by investigators who aim to examine macroautophagy and related processes, as well as for reviewers who need to provide realistic and reasonable critiques of papers that are focused on these processes. These guidelines are not meant to be a formulaic set of rules, because the appropriate assays depend in part on the question being asked and the system being used. In addition, we emphasize that no individual assay is guaranteed to be the most appropriate one in every situation, and we strongly recommend the use of multiple assays to monitor autophagy. In these guidelines, we consider these various methods of assessing autophagy and what information can, or cannot, be obtained from them. Finally, by discussing the merits and limits of particular autophagy assays, we hope to encourage technical innovation in the field.
  •  
7.
  • Feroci, M., et al. (författare)
  • The large observatory for x-ray timing
  • 2014
  • Ingår i: Proceedings of SPIE - The International Society for Optical Engineering. - : SPIE. - 9780819496126
  • Konferensbidrag (refereegranskat)abstract
    • The Large Observatory For x-ray Timing (LOFT) was studied within ESA M3 Cosmic Vision framework and participated in the final downselection for a launch slot in 2022-2024. Thanks to the unprecedented combination of effective area and spectral resolution of its main instrument, LOFT will study the behaviour of matter under extreme conditions, such as the strong gravitational field in the innermost regions of accretion flows close to black holes and neutron stars, and the supranuclear densities in the interior of neutron stars. The science payload is based on a Large Area Detector (LAD, 10 m2 effective area, 2-30 keV, 240 eV spectral resolution, 1° collimated field of view) and a Wide Field Monitor (WFM, 2-50 keV, 4 steradian field of view, 1 arcmin source location accuracy, 300 eV spectral resolution). The WFM is equipped with an on-board system for bright events (e.g. GRB) localization. The trigger time and position of these events are broadcast to the ground within 30 s from discovery. In this paper we present the status of the mission at the end of its Phase A study.
  •  
8.
  •  
9.
  • Abdo, A. A., et al. (författare)
  • The first fermi large area telescope catalog of gamma-ray pulsars
  • 2010
  • Ingår i: Astrophysical Journal Supplement Series. - : American Astronomical Society. - 0067-0049 .- 1538-4365. ; 187:2, s. 460-494
  • Tidskriftsartikel (refereegranskat)abstract
    • The dramatic increase in the number of known gamma-ray pulsars since the launch of the Fermi Gamma-ray Space Telescope (formerly GLAST) offers the first opportunity to study a sizable population of these high-energy objects. This catalog summarizes 46 high-confidence pulsed detections using the first six months of data taken by the Large Area Telescope (LAT), Fermi's main instrument. Sixteen previously unknown pulsars were discovered by searching for pulsed signals at the positions of bright gamma-ray sources seen with the LAT, or at the positions of objects suspected to be neutron stars based on observations at other wavelengths. The dimmest observed flux among these gamma-ray-selected pulsars is 6.0 x 10(-8) ph cm(-2) s(-1) (for E > 100 MeV). Pulsed gamma-ray emission was discovered from 24 known pulsars by using ephemerides (timing solutions) derived from monitoring radio pulsars. Eight of these new gamma-ray pulsars are millisecond pulsars. The dimmest observed flux among the radio-selected pulsars is 1.4 x 10(-8) ph cm(-2) s(-1) (for E > 100 MeV). The remaining six gamma-ray pulsars were known since the Compton Gamma Ray Observatory mission, or before. The limiting flux for pulse detection is non-uniform over the sky owing to different background levels, especially near the Galactic plane. The pulsed energy spectra can be described by a power law with an exponential cutoff, with cutoff energies in the range similar to 1-5 GeV. The rotational energy-loss rate ((E) over dot) of these neutron stars spans five decades, from similar to 3 x 10(33) erg s(-1) to 5 x 10(38) erg s(-1), and the apparent efficiencies for conversion to gammaray emission range from similar to 0.1% to similar to unity, although distance uncertainties complicate efficiency estimates. The pulse shapes show substantial diversity, but roughly 75% of the gamma-ray pulse profiles have two peaks, separated by greater than or similar to 0.2 of rotational phase. For most of the pulsars, gamma-ray emission appears to come mainly from the outer magnetosphere, while polar-cap emission remains plausible for a remaining few. Spatial associations imply that many of these pulsars power pulsar wind nebulae. Finally, these discoveries suggest that gamma-ray-selected young pulsars are born at a rate comparable to that of their radio-selected cousins and that the birthrate of all young gamma-ray-detected pulsars is a substantial fraction of the expected Galactic supernova rate.
  •  
10.
  • Abdo, A. A., et al. (författare)
  • DETECTION OF THE ENERGETIC PULSAR PSR B1509-58 AND ITS PULSAR WIND NEBULA IN MSH 15-52 USING THE FERMI-LARGE AREA TELESCOPE
  • 2010
  • Ingår i: Astrophysical Journal. - 0004-637X .- 1538-4357. ; 714:1, s. 927-936
  • Tidskriftsartikel (refereegranskat)abstract
    • We report the detection of high-energy gamma-ray emission from the young and energetic pulsar PSR B1509-58 and its pulsar wind nebula (PWN) in the composite supernova remnant G320.4-1.2 (aka MSH 15-52). Using 1 yr of survey data with the Fermi-Large Area Telescope (LAT), we detected pulsations from PSR B1509-58 up to 1 GeV and extended gamma-ray emission above 1 GeV spatially coincident with the PWN. The pulsar light curve presents two peaks offset from the radio peak by phases 0.96 +/- 0.01 and 0.33 +/- 0.02. New constraining upper limits on the pulsar emission are derived below 1 GeV and confirm a severe spectral break at a few tens of MeV. The nebular spectrum in the 1-100 GeV energy range is well described by a power law with a spectral index of (1.57 +/- 0.17 +/- 0.13) and a flux above 1 GeV of (2.91 +/- 0.79 +/- 1.35) x 10(-9) cm(-2) s(-1). The first errors represent the statistical errors on the fit parameters, while the second ones are the systematic uncertainties. The LAT spectrum of the nebula connects nicely with Cherenkov observations, and indicates a spectral break between GeV and TeV energies.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 28
Typ av publikation
tidskriftsartikel (26)
konferensbidrag (1)
forskningsöversikt (1)
Typ av innehåll
refereegranskat (25)
övrigt vetenskapligt/konstnärligt (3)
Författare/redaktör
Winer, B. L. (14)
Torres, D. F. (14)
Hughes, R. E. (13)
Buson, S. (13)
Longo, F. (13)
Paneque, D. (13)
visa fler...
Reimer, A. (13)
Reimer, O. (13)
Tibaldo, L. (13)
Ajello, M. (13)
Caliandro, G. A. (13)
Chiang, J. (13)
Cohen-Tanugi, J. (13)
Mizuno, T. (13)
Ohsugi, T. (12)
Bregeon, J. (12)
Funk, S. (12)
de Palma, F. (12)
Kerr, M. (12)
Barbiellini, G. (12)
Bellazzini, R. (12)
Bruel, P. (12)
Cameron, R. A. (12)
Caraveo, P. A. (12)
Ciprini, S. (12)
Favuzzi, C. (12)
Focke, W. B. (12)
Fusco, P. (12)
Gargano, F. (12)
Giglietto, N. (12)
Giordano, F. (12)
Guiriec, S. (12)
Johannesson, G. (12)
Kamae, T. (12)
Loparco, F. (12)
Lubrano, P. (12)
Mazziotta, M. N. (12)
Michelson, P. F. (12)
Monzani, M. E. (12)
Morselli, A. (12)
Nuss, E. (12)
Pesce-Rollins, M. (12)
Piron, F. (12)
Porter, T. A. (12)
Raino, S. (12)
Razzano, M. (12)
Siskind, E. J. (12)
Spinelli, P. (12)
Thayer, J. B. (12)
Wood, K. S. (12)
visa färre...
Lärosäte
Kungliga Tekniska Högskolan (12)
Stockholms universitet (9)
Karolinska Institutet (7)
Uppsala universitet (5)
Lunds universitet (3)
Göteborgs universitet (2)
visa fler...
Linköpings universitet (2)
Chalmers tekniska högskola (2)
Linnéuniversitetet (1)
Sveriges Lantbruksuniversitet (1)
visa färre...
Språk
Engelska (28)
Forskningsämne (UKÄ/SCB)
Naturvetenskap (21)
Medicin och hälsovetenskap (3)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy