SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Deans Abby E.)
 

Sökning: WFRF:(Deans Abby E.) > (2010) > Role of Fusion of P...

Role of Fusion of Prone FDG-PET and Magnetic Resonance Imaging of the Breasts in the Evaluation of Breast Cancer

Moy, Linda (författare)
New York University School of Medicine
Noz, Marilyn E. (författare)
New York University School of Medicine
Maguire, Gerald Q., Jr. (författare)
KTH,Kommunikationssystem, CoS
visa fler...
Melsaether, Amy (författare)
New York University School of Medicine
Deans, Abby E. (författare)
New York University School of Medicine
Murphy-Walcott, Antoinette D. (författare)
New York University School of Medicine
Ponzo, Fabio (författare)
New York University School of Medicine
visa färre...
 (creator_code:org_t)
2010-04-23
2010
Engelska.
Ingår i: The Breast Journal. - : Hindawi Limited. - 1075-122X .- 1524-4741. ; 16:4, s. 369-376
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The purpose of this study is to report further about the statistically significant results from a prospective study, which suggests that fusion of prone F-18 Fluoro-deoxy-glucose (FDG) positron emission tomography (PET) and magnetic resonance (MR) breast scans increases the positive predictive value (PPV) and specificity for patients in whom the MR outcome alone would be nonspecific. Thirty-six women (mean age, 43 years; range, 24-65 years) with 90 lesions detected on MR consented to undergo a FDG-PET scan. Two blinded readers evaluated the MR and the computer tomography (CT) attenuation-corrected prone FDG-PET scans side-by-side, then after the volumes were superimposed (fused). A semiautomatic, landmark-based program was used to perform nonrigid fusion. Pathology and radiologic follow-up were used as the reference standard. The sensitivity, specificity, PPV, negative predictive value (NPV), and accuracy (with 95% confidence intervals) for MR alone, FDG-PET alone, and fused MR and FDG-PET were calculated. The median lesion size measured from the MR was 2.5 cm (range, 0.5-10 cm). Histologically, 56 lesions were malignant, and 15 were benign. Nineteen lesions were benign after 20-47 months of clinical and radiologic surveillance. The sensitivity of MR alone was 95%, FDG-PET alone was 57%, and fusion was 83%. The increase in PPV from 77% in MR alone to 98% when fused and the increase in specificity from 53% to 97% were statistically significant (p < 0.05). The false-negative rate on FDG-PET alone was 26.7%, and after fusion this number was reduced to 9%. FDG-PET and MR fusions were helpful in selecting which lesion to biopsy, especially in women with multiple suspicious MR breast lesions.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)

Nyckelord

breast cancer
breast MR
fusion of breast scans
prone FDG-PET scans of the breast
Medical engineering
Medicinsk teknik

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy