SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Deng C.) srt2:(2005-2009)"

Sökning: WFRF:(Deng C.) > (2005-2009)

  • Resultat 1-10 av 17
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Schael, S, et al. (författare)
  • Precision electroweak measurements on the Z resonance
  • 2006
  • Ingår i: Physics Reports. - : Elsevier BV. - 0370-1573 .- 1873-6270. ; 427:5-6, s. 257-454
  • Forskningsöversikt (refereegranskat)abstract
    • We report on the final electroweak measurements performed with data taken at the Z resonance by the experiments operating at the electron-positron colliders SLC and LEP. The data consist of 17 million Z decays accumulated by the ALEPH, DELPHI, L3 and OPAL experiments at LEP, and 600 thousand Z decays by the SLID experiment using a polarised beam at SLC. The measurements include cross-sections, forward-backward asymmetries and polarised asymmetries. The mass and width of the Z boson, m(Z) and Gamma(Z), and its couplings to fermions, for example the p parameter and the effective electroweak mixing angle for leptons, are precisely measured: m(Z) = 91.1875 +/- 0.0021 GeV, Gamma(Z) = 2.4952 +/- 0.0023 GeV, rho(l) = 1.0050 +/- 0.0010, sin(2)theta(eff)(lept) = 0.23153 +/- 0.00016. The number of light neutrino species is determined to be 2.9840 +/- 0.0082, in agreement with the three observed generations of fundamental fermions. The results are compared to the predictions of the Standard Model (SM). At the Z-pole, electroweak radiative corrections beyond the running of the QED and QCD coupling constants are observed with a significance of five standard deviations, and in agreement with the Standard Model. Of the many Z-pole measurements, the forward-backward asymmetry in b-quark production shows the largest difference with respect to its SM expectation, at the level of 2.8 standard deviations. Through radiative corrections evaluated in the framework of the Standard Model, the Z-pole data are also used to predict the mass of the top quark, m(t) = 173(+10)(+13) GeV, and the mass of the W boson, m(W) = 80.363 +/- 0.032 GeV. These indirect constraints are compared to the direct measurements, providing a stringent test of the SM. Using in addition the direct measurements of m(t) and m(W), the mass of the as yet unobserved SM Higgs boson is predicted with a relative uncertainty of about 50% and found to be less than 285 GeV at 95% confidence level. (c) 2006 Elsevier B.V. All rights reserved.
  •  
2.
  • Ablikim, M., et al. (författare)
  • Measurements of (XcJ)-> K+K-K+K- decays
  • 2006
  • Ingår i: Physics Letters B. - : Elsevier BV. - 0370-2693 .- 1873-2445. ; 642:3, s. 197-202
  • Tidskriftsartikel (refereegranskat)abstract
    • Using 14M psi(2S) events taken with the BESII detector, chi(cJ) -> 2(K+K-) decays are studied. For the four-kaon final state, the branching fractions are B(chi(c0,1,2) ->.2(K+K-)) = (3.48 +/- 0.23 +/- 0.47) x 10(-3), (0.70 +/- 0.13 +/- 0.10) x 10(-3), and (2.17 +/- 0.20 +/- 0.31) x 10(-3). For the phi K+K- final state, the branching fractions, which are measured for the first time, are B(chi(c0,1,2) -> phi K+K-) = (1.03 +/- 0.22 +/- 0.15) x 10(-3), (0.46 +/- 0.16 +/- 0.06) x 10(-3), and (1.67 +/- 0.26 +/- 0.24) x 10(-4). For the phi phi final state, B(chi(c0,2) -> phi phi) = (0.94 +/- 0.21 +/- 0.13) x 10(-3) and (1.70 +/- 0.30 +/- 0.25) x 10(-3).
  •  
3.
  • Schaap, M., et al. (författare)
  • Standardized evaluation methodology and reference database for evaluating coronary artery centerline extraction algorithms
  • 2009
  • Ingår i: Medical Image Analysis. - : Elsevier. - 1361-8415 .- 1361-8423. ; 13:5, s. 701-714
  • Tidskriftsartikel (refereegranskat)abstract
    • Efficiently obtaining a reliable coronary artery centerline from computed tomography angiography data is relevant in clinical practice. Whereas numerous methods have been presented for this purpose, up to now no standardized evaluation methodology has been published to reliably evaluate and compare the performance of the existing or newly developed coronary artery centerline extraction algorithms. This paper describes a standardized evaluation methodology and reference database for the quantitative evaluation of coronary artery centerline extraction algorithms. The contribution of this work is fourfold: (1) a method is described to create a consensus centerline with multiple observers, (2) well-defined measures are presented for the evaluation of coronary artery centerline extraction algorithms, (3) a database containing 32 cardiac CTA datasets with corresponding reference standard is described and made available, and (4) 13 coronary artery centerline extraction algorithms, implemented by different research groups, are quantitatively evaluated and compared. The presented evaluation framework is made available to the medical imaging community for benchmarking existing or newly developed coronary centerline extraction algorithms.
  •  
4.
  • Berman, F., et al. (författare)
  • New grid scheduling and rescheduling methods in the GrADS Project
  • 2005
  • Ingår i: International journal of parallel programming. - : Springer Science and Business Media LLC. - 0885-7458 .- 1573-7640. ; 33:3-Feb, s. 209-229
  • Tidskriftsartikel (refereegranskat)abstract
    • The goal of the Grid Application Development Software (GrADS) Project is to provide programming tools and an execution environment to ease program development for the Grid. This paper presents recent extensions to the GrADS software framework: a new approach to scheduling workflow computations, applied to a 3-D image reconstruction application; a simple stop/migrate/restart approach to rescheduling Grid applications, applied to a QR factorization benchmark; and a process-swapping approach to rescheduling, applied to an N-body simulation. Experiments validating these methods were carried out on both the GrADS MacroGrid (a small but functional Grid) and the MicroGrid (a controlled emulation of the Grid).
  •  
5.
  •  
6.
  • Bunck, M. C., et al. (författare)
  • One-year treatment with exenatide improves beta-cell function, compared with insulin glargine, in metformin-treated type 2 diabetic patients: a randomized, controlled trial
  • 2009
  • Ingår i: Diabetes Care. - 1935-5548. ; 32:5, s. 762-8
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: Traditional blood glucose-lowering agents do not sustain adequate glycemic control in most type 2 diabetic patients. Preclinical studies with exenatide have suggested sustained improvements in beta-cell function. We investigated the effects of 52 weeks of treatment with exenatide or insulin glargine followed by an off-drug period on hyperglycemic clamp-derived measures of beta-cell function, glycemic control, and body weight. RESEARCH DESIGN AND METHODS: Sixty-nine metformin-treated patients with type 2 diabetes were randomly assigned to exenatide (n = 36) or insulin glargine (n = 33). beta-Cell function was measured during an arginine-stimulated hyperglycemic clamp at week 0, at week 52, and after a 4-week off-drug period. Additional end points included effects on glycemic control, body weight, and safety. RESULTS: Treatment-induced change in combined glucose- and arginine-stimulated C-peptide secretion was 2.46-fold (95% CI 2.09-2.90, P < 0.0001) greater after a 52-week exenatide treatment compared with insulin glargine treatment. Both exenatide and insulin glargine reduced A1C similarly: -0.8 +/- 0.1 and -0.7 +/- 0.2%, respectively (P = 0.55). Exenatide reduced body weight compared with insulin glargine (difference -4.6 kg, P < 0.0001). beta-Cell function measures returned to pretreatment values in both groups after a 4-week off-drug period. A1C and body weight rose to pretreatment values 12 weeks after discontinuation of either exenatide or insulin glargine therapy. CONCLUSIONS: Exenatide significantly improves beta-cell function during 1 year of treatment compared with titrated insulin glargine. After cessation of both exenatide and insulin glargine therapy, beta-cell function and glycemic control returned to pretreatment values, suggesting that ongoing treatment is necessary to maintain the beneficial effects of either therapy.
  •  
7.
  •  
8.
  • Deng, X. H., et al. (författare)
  • Dynamics and waves near multiple magnetic null points in reconnection diffusion region
  • 2009
  • Ingår i: Journal of Geophysical Research. - : Blackwell Publishing. - 0148-0227 .- 2156-2202. ; 114:7
  • Tidskriftsartikel (refereegranskat)abstract
    • Identifying the magnetic structure in the region where the magnetic field lines break and how reconnection happens is crucial to improving our understanding of three-dimensional reconnection. Here we show the in situ observation of magnetic null structures in the diffusion region, the dynamics, and the associated waves. Possible spiral null pair has been identified near the diffusion region. There is a close relation among the null points, the bipolar signature of the Z component of the magnetic field, and enhancement of the flux of energetic electrons up to 100 keV. Near the null structures, whistler-mode waves were identified by both the polarity and the power law of the spectrum of electric and magnetic fields. It is found that the angle between the fans of the nulls is quite close to the theoretically estimated maximum value of the group-velocity cone angle for the whistler wave regime of reconnection.
  •  
9.
  • Dirksen, A., et al. (författare)
  • Exploring the role of CT densitometry: a randomised study of augmentation therapy in alpha(1)-antitrypsin deficiency
  • 2009
  • Ingår i: European Respiratory Journal. - : European Respiratory Society (ERS). - 1399-3003 .- 0903-1936. ; 33:6, s. 1345-1353
  • Tidskriftsartikel (refereegranskat)abstract
    • Assessment of emphysema-modifying therapy is difficult, but newer outcome measures offer advantages over traditional methods. The EXAcerbations and Computed Tomography scan as Lung End-points (EXACTLE) trial explored the use of computed tomography (CT) densitometry and exacerbations for the assessment of the therapeutic effect of augmentation therapy in subjects with alpha(1)-antitrypsin (alpha(1)-AT) deficiency. In total, 77 subjects (protease inhibitor type Z) were randomised to weekly infusions of 60 mg.kg(-1) human alpha(1)-AT (Prolastin (R)) or placebo for 2-2.5 yrs. The primary end-point was change in CT lung density, and an exploratory approach was adopted to identify optimal methodology, including two methods of adjustment for lung volume variability and two statistical approaches. Other end-points were exacerbations, health status and physiological indices. CT was more sensitive than other measures of emphysema progression, and the changes in CT and forced expiratory volume in 1 s were correlated. All methods of densitometric analysis concordantly showed a trend suggestive of treatment benefit (p-values for Prolastin (R) versus placebo ranged 0.049-0.084). Exacerbation frequency was unaltered by treatment, but a reduction in exacerbation severity was observed. In patients with alpha(1)-AT deficiency, CT is a more sensitive outcome measure of emphysema-modifying therapy than physiology and health status, and demonstrates a trend of treatment benefit from alpha(1)-AT augmentation.
  •  
10.
  • Liu, Wenguang, et al. (författare)
  • Collagen-phosphorylcholine interpenetrating network hydrogels as corneal substitutes
  • 2009
  • Ingår i: BIOMATERIALS. - : Elsevier BV. - 0142-9612. ; 30:8, s. 1551-1559
  • Tidskriftsartikel (refereegranskat)abstract
    • A biointeractive collagen-phospholipid corneal Substitute was fabricated from interpenetrating polymeric networks comprising 1-ethyl-3-(3-dimethyl aminopropyl) carbodiimide and N-hydroxysuccinimide crosslinked porcine atelocollagen, and poly(ethylene glycol) diacrylate crosslinked 2-methacryloyloxyethyl phosphorylcholine (MPC). The resulting hydrogels showed ail overall increase in mechanical strength beyond that of either original component and enhanced stability against enzymatic digestion (by collagenase) or UV degradation. More strikingly, these hydrogels retained the full biointeractive, cell friendly properties of collagen in promoting corneal cell and nerve in-growth and, regeneration (despite MPCs known anti-adhesive properties). Measurements of refractive indices, white light transmission and backscatter showed the optical properties of collagen-MPC are comparable or superior to those of the human cornea.In addition, the glucose and albumin permeability were comparable to those Of human corneas. Twelve-month post-implantation results of collagen-MPC hydrogels into mini-pigs showed regeneration of corneal tissue (epithelium, stroma) as well as the tear film and sensory nerves. We also show that porcine collagen can be Substituted with recombinant human collagen, resulting in a fully-synthetic implant that is free from the potential risks of disease transmission (e.g. prions) present in animal Source materials.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 17

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy