SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Dixit M.) srt2:(2010-2014)"

Sökning: WFRF:(Dixit M.) > (2010-2014)

  • Resultat 1-7 av 7
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Schael, S., et al. (författare)
  • Electroweak measurements in electron positron collisions at W-boson-pair energies at LEP
  • 2013
  • Ingår i: Physics Reports. - : Elsevier BV. - 0370-1573 .- 1873-6270. ; 532:4, s. 119-244
  • Forskningsöversikt (refereegranskat)abstract
    • Electroweak measurements performed with data taken at the electron positron collider LEP at CERN from 1995 to 2000 are reported. The combined data set considered in this report corresponds to a total luminosity of about 3 fb(-1) collected by the four LEP experiments ALEPH, DELPHI, 13 and OPAL, at centre-of-mass energies ranging from 130 GeV to 209 GeV. Combining the published results of the four LEP experiments, the measurements include total and differential cross-sections in photon-pair, fermion-pair and four-fermion production, the latter resulting from both double-resonant WW and ZZ production as well as singly resonant production. Total and differential cross-sections are measured precisely, providing a stringent test of the Standard Model at centre-of-mass energies never explored before in electron positron collisions. Final-state interaction effects in four-fermion production, such as those arising from colour reconnection and Bose Einstein correlations between the two W decay systems arising in WW production, are searched for and upper limits on the strength of possible effects are obtained. The data are used to determine fundamental properties of the W boson and the electroweak theory. Among others, the mass and width of the W boson, m(w) and Gamma(w), the branching fraction of W decays to hadrons, B(W -> had), and the trilinear gauge-boson self-couplings g(1)(Z), K-gamma and lambda(gamma), are determined to be: m(w) = 80.376 +/- 0.033 GeV Gamma(w) = 2.195 +/- 0.083 GeV B(W -> had) = 67.41 +/- 0.27% g(1)(Z) = 0.984(-0.020)(+0.018) K-gamma - 0.982 +/- 0.042 lambda(gamma) = 0.022 +/- 0.019. (C) 2013 Elsevier B.V. All rights reserved.
  •  
2.
  • Ederle, Joerg, et al. (författare)
  • Carotid artery stenting compared with endarterectomy in patients with symptomatic carotid stenosis (International Carotid Stenting Study): an interim analysis of a randomised controlled trial
  • 2010
  • Ingår i: The Lancet. - 1474-547X. ; 375:9719, s. 985-997
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Stents are an alternative treatment to carotid endarterectomy for symptomatic carotid stenosis, but previous trials have not established equivalent safety and efficacy. We compared the safety of carotid artery stenting with that of carotid endarterectomy. Methods The International Carotid Stenting Study (ICSS) is a multicentre, international, randomised controlled trial with blinded adjudication of outcomes. Patients with recently symptomatic carotid artery stenosis were randomly assigned in a 1:1 ratio to receive carotid artery stenting or carotid endarterectomy. Randomisation was by telephone call or fax to a central computerised service and was stratified by centre with minimisation for sex, age, contralateral occlusion, and side of the randomised artery. Patients and investigators were not masked to treatment assignment. Patients were followed up by independent clinicians not directly involved in delivering the randomised treatment. The primary outcome measure of the trial is the 3-year rate of fatal or disabling stroke in any territory, which has not been analysed yet. The main outcome measure for the interim safety analysis was the 120-day rate of stroke, death, or procedural myocardial infarction. Analysis was by intention to treat (ITT). This study is registered, number ISRCTN25337470. Findings The trial enrolled 1713 patients (stenting group, n=855; endarterectomy group, n=858). Two patients in the stenting group and one in the endarterectomy group withdrew immediately after randomisation, and were not included in the ITT analysis. Between randomisation and 120 days, there were 34 (Kaplan-Meier estimate 4.0%) events of disabling stroke or death in the stenting group compared with 27 (3.2%) events in the endarterectomy group (hazard ratio [HR] 1.28, 95% CI 0.77-2.11). The incidence of stroke, death, or procedural myocardial infarction was 8.5% in the stenting group compared with 5.2% in the endarterectomy group (72 vs 44 events; HR 1.69, 1.16-2.45, p=0.006), Risks of any stroke (65 vs 35 events; HR 1.92, 1.27-2.89) and all-cause death (19 vs seven events; HR 2.76, 1.16-6.56) were higher in the stenting group than in the endarterectomy group. Three procedural myocardial infarctions were recorded in the stenting group, all of which were fatal, compared with four, all non-fatal, in the endarterectomy group. There was one event of cranial nerve palsy in the stenting group compared with 45 in the endarterectomy group. There were also fewer haematomas of any severity in the stenting group than in the endarterectomy group (31 vs 50 events; p=0.0197). Interpretation Completion of long-term follow-up is needed to establish the efficacy of carotid artery stenting compared with endarterectomy. In the meantime, carotid endarterectomy should remain the treatment of choice for patients suitable for surgery.
  •  
3.
  •  
4.
  •  
5.
  • Dixit, A., et al. (författare)
  • Efficient protection schemes for hybrid WDM/TDM Passive Optical Networks
  • 2012
  • Ingår i: Communications (ICC), 2012 IEEE International Conference on. - : IEEE. - 9781457720529 ; , s. 6220-6224
  • Konferensbidrag (refereegranskat)abstract
    • Hybrid WDM/TDM Passive Optical Network (PON) is a promising candidate for next-generation optical access (NGOA) solutions as it is able to offer a high splitting ratio and consequently achieves a relatively low cost and power consumption on a per-user basis compared with other NGOA architectures. On the other hand, the end users require a certain level of connection availability while the operators need to reduce the failure impact (i.e. to avoid a huge number of end users being affected by any single failure). Therefore, by evaluating the connection availability and failure impact robustness we identify the most efficient parts to provide resilience in a hybrid WDM/TDM PON from an operator and an end-user perspective. Then, we select the appropriate protection schemes to construct some novel reliable architectures and analyze their reliability performance in urban and rural scenarios. In this way, this paper provides a comprehensive insight into the most relevant protection mechanisms for hybrid WDM/TDM PONs.
  •  
6.
  • Dixit, A., et al. (författare)
  • Protection strategies for Next Generation Passive Optical Networks -2
  • 2014
  • Ingår i: 2014 International Conference on Optical Network Design and Modeling. ; , s. 13-18
  • Konferensbidrag (refereegranskat)abstract
    • Next Generation Passive Optical Networks-2 (NG-PON2) are being considered to upgrade the current PON technology to meet the ever increasing bandwidth requirements of the end users while optimizing the network operators’ investment. Reliability performance of NG-PON2 is very important due to the extended reach and, consequently, large number of served customers per PON segment. On the other hand, the use of more complex and hence more failure prone components than in the current PON systems may degrade reliability performance of the network. Thus designing reliable NG-PON2 architectures is of a paramount importance. Moreover, for appropriately evaluating network reliability performance, new models are required. For example, the commonly used reliability parameter, i.e., connection availability, defined as the percentage of time for which a connection remains operable, doesn’t reflect the network wide reliability performance. The network operators are often more concerned about a single failure affecting a large number of customers than many uncorrelated failures disconnecting fewer customers while leading to the same average failure time. With this view, we introduce a new parameter for reliability performance evaluation, referred to as the failure impact. In this paper, we propose several reliable architectures for two important NG-PON2 candidates: wavelength division multiplexed (WDM) PON and time and wavelength division multiplexed (TWDM) PON. Furthermore, we evaluate protection coverage, availability, failure impact and cost of the proposed schemes in order to identify the most efficient protection architecture.
  •  
7.
  • Dixit, M., et al. (författare)
  • Scandium-decorated MOF-5 as potential candidates for room-temperature hydrogen storage : A solution for the clustering problem in MOFs
  • 2012
  • Ingår i: The Journal of Physical Chemistry C. - : American Chemical Society (ACS). - 1932-7447 .- 1932-7455. ; 116:33, s. 17336-17342
  • Tidskriftsartikel (refereegranskat)abstract
    • Transition-metal-based systems show promising binding energy for hydrogen storage but suffer from clustering problem. The effect of light transition metal (M = Sc, Ti) decoration, boron substitution on the hydrogen storage properties of MOF-5, and clustering problem of metals has been investigated using ab initio density functional theory. Our results of solid-tate calculations reveal that whereas Ti clusters strongly Sc atoms do not suffer from this problem when decorating MOF-5. Boron substitution on metal-decorated MOF-5 enhances the interaction energy of both the metals with MOF-5. Sc-decorated MOF-5 shows a hydrogen storage capacity of 5.81 wt % with calculated binding energies of 20-40 kJ/mol, which ensures the room-temperature applicability of this hydrogen storage material.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-7 av 7

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy