SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Dubnika Hauksson Inese) srt2:(2010)"

Sökning: WFRF:(Dubnika Hauksson Inese) > (2010)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Dubnika Hauksson, Inese, et al. (författare)
  • Routine diagnostic patch-testing with formaldehyde 2.0% (0.6 mg/cm2) may be an advantage compared to 1.0%.
  • 2010
  • Ingår i: Acta Dermato-Venereologica. - : Medical Journals Sweden AB. - 1651-2057 .- 0001-5555. ; 90:5, s. 480-484
  • Tidskriftsartikel (refereegranskat)abstract
    • Our clinical experience has suggested that the presently recommended patch-test concentration (1.0%) for formaldehyde in the baseline series might be too low. Therefore, consecutively patch-tested dermatitis patients were tested simultaneously with formaldehyde 1.0% and 2.0% (w/v) in aqua. Formaldehyde 1.0% and 2.0% were applied with a micro-pipette (15 microl) to filter paper discs in Finn Chambers (0.30 mg/cm(2) and 0.60 mg/cm(2), respectively). A total of 1397 patients with dermatitis were patch-tested. In all, 68 (4.9%) patients reacted positively to formaldehyde; 37 reacted only to 2.0%, 29 reacted to both concentrations, and 2 reacted only to 1.0%. Significantly more patients were thus diagnosed with contact allergy to formaldehyde 2.0% compared with 1.0% (p < 0.001). We detected 0.1%, 0.4%, and 29.6% irritant reactions to 1.0%, 2.0%, and 3.0% formaldehyde, respectively. We conclude that, with an optimized patch-test technique, doubling the dose per area detects significantly more contact allergies to formaldehyde, but an even higher test concentration causes too many irritant reactions to be usable.
  •  
2.
  • Engfeldt, Malin, et al. (författare)
  • Comparison of three different techniques for application of water solutions to Finn Chambers®.
  • 2010
  • Ingår i: Contact Dermatitis. - : Wiley. - 0105-1873. ; 63:5, s. 284-288
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: With regard to contact allergy, the dose of a sensitizer per unit skin area is an important factor for both sensitization and elicitation, and therefore a known amount/volume of test preparation should be applied at patch testing. OBJECTIVES: To compare three different techniques for the application of aqueous solutions to Finn Chambers, in order to determine the precision and accuracy of each technique when the recommended 15 µl volume is applied. METHODS: Four technicians applied formaldehyde 1.0% aq. (wt/vol) and methylchloroisothiazolinone/methylisothiazolinone 200 ppm (wt/vol) in sets of 10 onto Finn Chambers, with three different techniques: (i) micro-pipetting; (ii) dripping the solutions; and (iii) dripping the solutions followed by removal of excess solution with a soft tissue. Assessment of the variations was performed with the use of descriptive data. The ability to apply the exact amount was assessed by Fisher's exact test by categorizing each application as in or out of the range 12-18 µl. RESULTS/CONCLUSIONS: The micro-pipette technique had the best accuracy and precision, as well as the lowest inter-individual variation. The technique in which excess solution was removed had good precision, but failed in the application of the defined amount, i.e. 15 µl.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2
Typ av publikation
tidskriftsartikel (2)
Typ av innehåll
refereegranskat (2)
Författare/redaktör
Bruze, Magnus (2)
Isaksson, Marléne (2)
Gruvberger, Birgitta (2)
Pontén, Ann (2)
Dubnika Hauksson, In ... (2)
Engfeldt, Malin (1)
Lärosäte
Lunds universitet (2)
Språk
Engelska (2)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (2)
År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy