1.
  • Carlson, Tobias, 1976, et al. (författare)
  • Interference of transcutaneous electrical nerve stimulation with permanent ventricular stimulation: a new clinical problem?
  • 2009
  • Ingår i: Europace. - 1532-2092. ; 11:3, s. 364-9
  • Tidskriftsartikel (refereegranskat)abstract
    • AIMS: To assess the compatibility of thoracic TENS and permanent PM treatment and to identify any signs of interference of TENS with the PM function. METHODS AND RESULTS: Twenty-seven patients treated with PM were tested. Transcutaneous electric nerve stimulation electrodes were placed above each mamilla, and the stimulation intensity was increased to the maximum level tolerated for 30 s or until electrocardiogram revealed signs of interference. Transcutaneous electric nerve stimulation of 2 and 80 Hz was tested with the PM ventricular sensing level set to the clinically chosen level as well as to maximal sensitivity. Interference was detected in 22 of 27 patients (81%). Low-frequency (2 Hz) stimulation was more associated with PM interference (52% at normal vs. 81% at maximal ventricular sensitivity) than high-frequency (80 Hz) stimulation (33% at normal vs. 63% at maximal ventricular sensitivity); although the differences were not statistically significant. CONCLUSION: Transcutaneous electric nerve stimulation frequently induces inhibition of the PM function already at the clinically set ventricular sensitivity. Therefore, individual testing is warranted before TENS treatment is considered in patients with a PM. A test protocol for TENS and PM interaction is proposed.
  •  
2.
  • Holmgren, C., et al. (författare)
  • Risk of interference from transcutaneous electrical nerve stimulation on the sensing function of implantable defibrillators
  • 2008
  • Ingår i: Pacing Clin Electrophysiol. - 1540-8159. ; 31:2, s. 151-8
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: The use of transcutaneous electrical nerve stimulation (TENS) for pain relief is increasing. At the same time the implantable cardioverter defibrillator (ICD) is a routine treatment for malignant tachyarrhythmias. Today patients often need devices for more than one condition, and consideration must be given to the interaction between them. We studied the risk of interference between TENS and the ICD function. METHODS AND RESULTS: Thirty patients who had received an ICD underwent a test protocol including TENS at the mammilla and hip levels, at two energy levels, and at the highest comfortable stimulation level. The effects of TENS on the electrocardiogram lead II, intracardiac electrograms, and the ICD marker channels were analyzed. Disturbance from TENS on the sensing function was seen at all stimulation attempts. Interference between the systems was observed in 16 patients. In eight patients (27%) the interpretation was VT/VF and in 14 patients (47%) as ventricular premature extra beats. Other kinds of interactions were seen in five patients (16%). Each patient could have more than one kind of interference. CONCLUSIONS: Noise reversion and undersensing might prevent the ICD from delivering shock when it should and the interpretation as VT/VF could result in inappropriate shocks. Because of the potentially serious consequences of interference we do not recommend the use of TENS in patients with ICD.
  •  
3.
  • Aunes-Jansson, Maria, et al. (författare)
  • T wave inversions following ablation of 125 posteroseptal accessory pathways
  • 2006
  • Ingår i: Int J Cardiol. - : Elsevier BV. - 0167-5273. ; 106:1, s. 75-81
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Cardiac memory, electrophysiological remodeling induced by periods of altered ventricular activation, has been observed after resumption of normal activation following ablation of overt accessory pathways. We studied the occurrence and temporal characteristics of cardiac memory (inferior T wave inversions) after ablation of overt posteroseptal accessory pathways. METHODS: T wave changes were assessed in the frontal plane (leads II, aVF, and III) up to one year after the ablation in 125 consecutive patients. T wave polarity immediately after ablation was compared with the pre ablation delta wave polarity and the dominant QRS force in each lead. The number of inferior leads (0-3) with post ablation T wave changes (estimate of degree of cardiac memory) was analyzed in relation to estimates of the degree of preexcitation (accessory pathway refractoriness and QRS duration) prior to ablation. RESULTS: Electrocardiogram (ECG) signs of cardiac memory were present in 123 (98%) of the patients within one day after ablation. The post ablation T wave vector had the same direction as the vector of the pre-excited QRS complex (and delta wave) creating inferior T wave inversions. There was no correlation between the degree of preexcitation pre ablation and the extent of cardiac memory post ablation. A majority (about 90%) of ECGs recorded 3-6 months after the procedure, showed complete or almost complete normalization. CONCLUSIONS: T wave inversions were present in the vast majority of patients, persisted in some patients beyond 3 months, and might be misinterpreted as inferior wall ischemia.
  •  
4.
  • Blomström-Lundqvist, Carina, et al. (författare)
  • A randomized double-blind study of epicardial left atrial cryoablation for permanent atrial fibrillation in patients undergoing mitral valve surgery: the SWEDish Multicentre Atrial Fibrillation study (SWEDMAF).
  • 2007
  • Ingår i: European heart journal. - : Oxford University Press (OUP). - 0195-668X .- 1522-9645. ; 28:23, s. 2902-8
  • Tidskriftsartikel (refereegranskat)abstract
    • AIMS: The efficacy of epicardial left atrial (LA) cryoablation in eliminating atrial fibrillation (AF) in patients undergoing mitral valve surgery (MVS) is unknown. We hypothesized that MVS combined with LA cryoablation is superior to MVS alone. METHODS AND RESULTS: Sixty-nine patients with permanent AF, included at four centres, underwent MVS with or without epicardial LA cryoablation. The primary endpoint was regained sinus rhythm. Risk factors for failed AF cryoablation were elucidated. Sixty-five out of 69 patients reached the primary endpoint. At 6 and 12 months follow-up, 73.3% of patients who underwent cryoablation had regained sinus rhythm at both follow-ups, compared with 45.7 and 42.9% of patients, respectively, who underwent MVS alone (group differences, at 6 months P = 0.024, after 12 months P = 0.013). The in-hospital complication rate was 11.4% in the MVS group and 26.5% in the cryoablation group (P = 0.110). Risk factors for failed elimination of AF by cryoablation were duration of permanent AF (P = 0.012) and presence of coronary artery disease (P = 0.047), according to multiple logistic regression analysis. CONCLUSION: This first prospective randomized study showed that combining MVS with epicardial LA cryoablation is significantly better in eliminating pre-operative permanent AF than MVS alone.
  •  
5.
  • Boriani, Giuseppe, et al. (författare)
  • Plateau waveform shape allows a much higher patient shock energy tolerance in AF patients.
  • 2007
  • Ingår i: Journal of cardiovascular electrophysiology. - : Wiley. - 1540-8167 .- 1045-3873. ; 18:7, s. 728-34
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • OBJECTIVES: To evaluate the possible pain reduction of the plateau waveform in atrial fibrillation (AF) patients. BACKGROUND: Previous studies have indicated that reduced amplitude waveforms would be less painful than a conventional (65/65% tilt) biphasic waveform. Computer modeling suggested that a moderately long (10-12 msec) plateau (flat topped) shock waveform would deliver equivalent effectiveness with the lowest possible peak amplitude. METHODS: We enrolled 27 patients at two sites with persistent AF with a total of 220 shocks delivered during internal atrial cardioversion using an interleaved crossover design. Patient response was scored in three ways: (1) a verbally reported discomfort score, (2) visual analog scale (VAS), and (3) a blinded observer reporting a contraction score. RESULTS: All scores were significantly reduced (P < 0.0001) by the plateau waveform with impressive statistics: Verbal discomfort (3.51 +/- 0.13 to 2.89 +/- 0.12), VAS (7.00 +/- 0.56 to 5.91 +/- 0.36), and contraction scores (1.94 +/- 0.12 to 1.62 +/- 0.12). The average pain threshold shift (TS) for the Verbal score was 2.34, while that for the VAS score was 2.30. (This means that the patient typically could tolerate 2.34 times as much energy with the plateau waveform for the same level of verbally reported discomfort.) The contraction TS was less at 1.57. Response scores were also corrected for the shock sequence number to control for the sensitization effect from multiple shocks. This increased the TS for the Verbal score to 3.58, but the shock number was not significant for the VAS. A pulmonary artery electrode return was associated with lower pain compared with a coronary sinus position. CONCLUSION: A plateau shaped biphasic waveform resulted in significantly increased shock energy pain tolerances. Controlling for session sensitization, patients tolerated over three times as much energy for the same verbally reported discomfort score.
  •  
6.
  • Camm, A J, et al. (författare)
  • Conventional and dedicated atrial overdrive pacing for the prevention of paroxysmal atrial fibrillation: the AFTherapy study.
  • 2007
  • Ingår i: Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. - : Oxford University Press (OUP). - 1532-2092. ; 9:12, s. 1110-8
  • Tidskriftsartikel (refereegranskat)abstract
    • AIMS: This investigation was conducted to determine the effectiveness of several conventional overdrive pacing modalities (single rate and rate responsive pacing at various lower rates) and of four dedicated preventive pacing algorithms in the suppression of paroxysmal atrial fibrillation (AF). METHOD AND RESULTS: In this multi-centre, randomized trial, 372 patients with drug-refractory paroxysmal AF were enrolled. Patients received a dual-chamber pacing device capable of delivering conventional pacing therapy as well as dedicated AF prevention pacing therapies and to record detailed AF-related diagnostics. The primary endpoint was AF burden, whereas secondary endpoints were time to first AF episode and averaged sinus rhythm duration. During a conventional pacing phase, patients were randomized to single rate or rate-responsive pacing with lower rates of either 70 or 85 min(-1) or to a control group with single rate pacing at 40 min(-1). In the subsequent preventive pacing phase, patients underwent pacing at a lower rate of 70 min(-1) with or without concomitant application of four preventive pacing algorithms. A substantial amount of data was excluded from the analysis because of atrial-sensing artefacts, identified in the device-captured diagnostics. In the conventional pacing phase, no significant differences were found between various lower rates and the control group receiving single rate pacing at 40 min(-1) or between single rate and rate-responsive pacing. Patients receiving preventive pacing with all four therapies enabled had a similar AF burden compared with patients treated with conventional pacing at 70 min(-1) (P = 0.47). CONCLUSIONS: The results do not demonstrate a significant effect of conventional atrial overdrive pacing or preventive pacing therapies. However, the observations provided important information for further consideration with respect to the design and conduct of future studies on the effect of atrial pacing therapies for the reduction of AF.
  •  
7.
  •  
8.
  • Dota, Corina-Dana, et al. (författare)
  • PC-Based ECG waveform recognition-validation of novel software against a reference ECG database
  • 2009
  • Ingår i: Ann Noninvasive Electrocardiol. - 1542-474X. ; 14 Suppl 1
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: PC-based ECG measurements must cope with normal as well as pathological ECGs in a reliable manner. EClysis, a software for ECG measurements was tested against reference values from the Common Standards for Quantitative Electrocardiography (CSE) database. METHODS: Digital ECGs (12 leads, 500 Hz) were recorded by the CSE project. Data Set 3 contains reference values for 125 ECGs (33 normal and 92 pathological). Median values of measurements by 11 computer programs and by five cardiologists, respectively, refer to the earliest P and QRS onsets and to the latest P, QRS, and T offsets in any lead of a selected (index) beat. EClysis automatically measured all ECGs, without user interference. RESULTS: The PQRST points were correctly detected but in two ECGs with AV block II-III. The software was not designed to detect atrial activity in atrial fibrillation (n = 9) and flutter (n = 1). In one case of atrial fibrillation, atrial activity interfered with positioning of QRS and T offsets. Regression coefficients between EClysis and CSE (software-generated and human) were above 0.95 (P < 0.0001). The confidence intervals were 95% for the slope and the intercept of the regression lines. CONCLUSIONS: The PC-based detection and analysis of PQRST points showed a high level of agreement with the CSE database reference values.
  •  
9.
  • Flemme, Inger, et al. (författare)
  • Long-term quality of life and uncertainty in patients living with an implantable cardioverter defibrillator.
  • 2005
  • Ingår i: Heart & lung : the journal of critical care. - St. Louis, MO : Elsevier BV. - 0147-9563 .- 1527-3288. ; 34:6, s. 386-92
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: This study describes the quality of life (QOL) and uncertainty in patients who have an implantable cardioverter defibrillator (ICD) and predicts QOL at long-term follow-up. METHODS: Long-term follow-up was defined as 6.9 years +/- 1 year (range 4.11-8.7 years). QOL was measured with the Quality of Life Index, and uncertainty was measured with the Mishel Uncertainty in Illness Scale. RESULTS: The overall QOL and health/functioning were unchanged over time. QOL in the socioeconomic (P = .002) and psychologic/spiritual domains (P = .012) decreased in the first year. From baseline to long-term follow-up, the QOL in the family domain (P = .011) and uncertainty (P = .002) decreased. Uncertainty was a predictor of low QOL. CONCLUSION: QOL was reasonably good 6.9 years post-ICD implantation. Patients felt less uncertain once they had passed the first year of their illness.
  •  
10.
  • Friberg, L., et al. (författare)
  • The prognosis of patients with atrial fibrillation is improved when sinus rhythm is restored: report from the Stockholm Cohort of Atrial Fibrillation (SCAF)
  • 2009
  • Ingår i: Heart. - 1468-201X. ; 95:12, s. 1000-5
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Clinical trials have indicated that an active rhythm control strategy aiming at restoration of sinus rhythm in patients with atrial fibrillation (AF) is no better than a rate-control strategy in terms of mortality and morbidity. To what extent restoration and maintenance of sinus rhythm per se affect long-term prognosis in AF patients is less clear. AIM: To investigate if there are differences in mortality and morbidity between direct current (DC)-cardioverted AF patients who remain in sinus rhythm after cardioversion and those who relapse early. Method: 361 cardioverted patients from the Stockholm Cohort Study on Atrial Fibrillation were studied by means of medical records and national registers. Patients were followed for a mean of 4.2 years from DC cardioversion regarding all-cause mortality and for a mean of 3.2 years for a composite endpoint of death, ischaemic stroke, myocardial infarction or hospitalisation for heart failure. RESULTS: All-cause mortality tended to be lower in patients who had been successfully cardioverted and had had no known relapse of AF within the first 3 months after cardioversion (hazard ratio (HR) 0.57, 95% CI 0.30 to 1.06, p = 0.076). They also had a significantly lower incidence of the composite endpoint than those who relapsed early (HR 0.51, 95% CI 0.32 to 0.82, p = 0.0058). CONCLUSION: Restoration and 3 months maintenance of sinus rhythm was associated with improved long-term prognosis. The results imply that an active DC cardioversion approach is justified.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 25
Typ av publikation
tidskriftsartikel (25)
Typ av innehåll
refereegranskat (24)
övrigt vetenskapligt/konstnärligt (1)
Författare/redaktör
Edvardsson, Nils, 19 ... (25)
Karlsson, Thomas, 19 ... (4)
Berglin, Eva, 1947 (3)
Herlitz, Johan, 1949 (2)
Wallander, Mari-Ann (2)
Johansson, Saga (2)
visa fler...
Johansson, Birgitta, ... (2)
Poci, Dritan, 1969- (2)
Mannheimer, Clas, 19 ... (2)
Bergfeldt, Lennart, ... (1)
Wecke, L (1)
Hammar, N (1)
Pershagen, Göran (1)
Dota, Corina-Dana (1)
Skallefell, B. (1)
Rosenqvist, M (1)
Friberg, L. (1)
Nilsson, Leif (1)
Källner, Göran (1)
Holmgren, Anders (1)
Blomström-Lundqvist, ... (1)
Löfmark, Rurik (1)
Boriani, Giuseppe (1)
Gold, Michael R (1)
Fridlund, Bengt (1)
Ruigomez, Ana (1)
Wierup, Per (1)
Bellander, Tom (1)
Ekman, Inger, 1952 (1)
Berglind, Niklas (1)
Jensen, Steen (1)
Rosenqvist, Mårten (1)
Carlsson, Jonas (1)
Gadler, Fredrik (1)
Nilsson, Michael (1)
Houltz, Birgitta, 19 ... (1)
Sjögren, Bengt (1)
Andréll, Paulin, 197 ... (1)
Ekre, Olof, 1965 (1)
Ritter, P. (1)
Thelin, Stefan (1)
Kennergren, Charles, ... (1)
Ljungman, Petter L. ... (1)
Währborg, Peter, 195 ... (1)
Blomström, Per (1)
Aunes-Jansson, Maria (1)
Lurje, L. (1)
Taborsky, Milos (1)
Fauchier, Laurent (1)
Brandrup-Wognsen, Gu ... (1)
visa färre...
Lärosäte
Göteborgs universitet (25)
Karolinska Institutet (4)
Uppsala universitet (3)
Lunds universitet (2)
Högskolan i Borås (2)
Umeå universitet (1)
visa fler...
Högskolan i Halmstad (1)
Linköpings universitet (1)
Jönköping University (1)
Högskolan i Skövde (1)
Linnéuniversitetet (1)
visa färre...
Språk
Engelska (25)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (8)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy