SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Fahey M. C.) srt2:(2005-2009)"

Sökning: WFRF:(Fahey M. C.) > (2005-2009)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Schael, S, et al. (författare)
  • Precision electroweak measurements on the Z resonance
  • 2006
  • Ingår i: Physics Reports. - : Elsevier BV. - 0370-1573 .- 1873-6270. ; 427:5-6, s. 257-454
  • Forskningsöversikt (refereegranskat)abstract
    • We report on the final electroweak measurements performed with data taken at the Z resonance by the experiments operating at the electron-positron colliders SLC and LEP. The data consist of 17 million Z decays accumulated by the ALEPH, DELPHI, L3 and OPAL experiments at LEP, and 600 thousand Z decays by the SLID experiment using a polarised beam at SLC. The measurements include cross-sections, forward-backward asymmetries and polarised asymmetries. The mass and width of the Z boson, m(Z) and Gamma(Z), and its couplings to fermions, for example the p parameter and the effective electroweak mixing angle for leptons, are precisely measured: m(Z) = 91.1875 +/- 0.0021 GeV, Gamma(Z) = 2.4952 +/- 0.0023 GeV, rho(l) = 1.0050 +/- 0.0010, sin(2)theta(eff)(lept) = 0.23153 +/- 0.00016. The number of light neutrino species is determined to be 2.9840 +/- 0.0082, in agreement with the three observed generations of fundamental fermions. The results are compared to the predictions of the Standard Model (SM). At the Z-pole, electroweak radiative corrections beyond the running of the QED and QCD coupling constants are observed with a significance of five standard deviations, and in agreement with the Standard Model. Of the many Z-pole measurements, the forward-backward asymmetry in b-quark production shows the largest difference with respect to its SM expectation, at the level of 2.8 standard deviations. Through radiative corrections evaluated in the framework of the Standard Model, the Z-pole data are also used to predict the mass of the top quark, m(t) = 173(+10)(+13) GeV, and the mass of the W boson, m(W) = 80.363 +/- 0.032 GeV. These indirect constraints are compared to the direct measurements, providing a stringent test of the SM. Using in addition the direct measurements of m(t) and m(W), the mass of the as yet unobserved SM Higgs boson is predicted with a relative uncertainty of about 50% and found to be less than 285 GeV at 95% confidence level. (c) 2006 Elsevier B.V. All rights reserved.
  •  
2.
  • Kroeger, J., et al. (författare)
  • Specific food group combinations explaining the variation in intakes of nutrients and other important food components in the European Prospective Investigation into Cancer and Nutrition: an application of the reduced rank regression method
  • 2009
  • Ingår i: European Journal of Clinical Nutrition. - : Springer Science and Business Media LLC. - 1476-5640 .- 0954-3007. ; 63:4s, s. 263-274
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: To identify combinations of food groups that explain as much variation in absolute intakes of 23 key nutrients and food components as possible within the country-specific populations of the European Prospective Investigation into Cancer and Nutrition (EPIC). Subjects/Methods: The analysis covered single 24-h dietary recalls (24-HDR) from 36 034 subjects (13 025 men and 23 009 women), aged 35-74 years, from all 10 countries participating in the EPIC study. In a set of 39 food groups, reduced rank regression (RRR) was used to identify those combinations (RRR factors) that explain the largest proportion of variation in intake of 23 key nutrients and food components, namely, proteins, saturated fatty acids, monounsaturated fatty acids, polyunsaturated fatty acids, cholesterol, sugars (sum of mono-and disaccharides), starch, fibre, alcohol, calcium, iron, potassium, phosphorus, magnesium, vitamin D, beta-carotene, retinol and vitamins E, B1, B2, B6, B12 and C (RRR responses). Analyses were performed at the country level and for all countries combined. Results: In the country-specific analyses, the first RRR factor explained a considerable proportion of the total nutrient intake variation in all 10 countries (27.4-37.1%). The subsequent RRR factors were much less important in explaining the variation (<= 6%). Strong similarities were observed for the first country-specific RRR factor between the individual countries, largely characterized by consumption of bread, vegetable oils, red meat, milk, cheese, potatoes, margarine and processed meat. The highest explained variation was seen for protein, potassium, phosphorus and magnesium (50-70%), whereas sugars, beta-carotene, retinol and alcohol were only marginally explained (<= 5%). The explained proportion of the other nutrients ranged between these extremes. Conclusions: A combination of food groups was identified that explained a considerable proportion of the nutrient intake variation in 24-HDRs in every country-specific EPIC population in a similar manner. This indicates that, despite the large variability in food and nutrient intakes reported in the EPIC, the variance of intake of important nutrients is explained, to a large extent, by similar food group combinations across countries. European Journal of Clinical Nutrition (2009) 63, S263-S274; doi: 10.1038/ejcn.2009.85
  •  
3.
  • Ferrari, P., et al. (författare)
  • A bivariate measurement error model for nitrogen and potassium intakes to evaluate the performance of regression calibration in the European Prospective Investigation into Cancer and Nutrition study
  • 2009
  • Ingår i: European Journal of Clinical Nutrition. - : Springer Science and Business Media LLC. - 1476-5640 .- 0954-3007. ; 63:4s, s. 179-187
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: Within the European Prospective Investigation into Cancer and Nutrition (EPIC) study, the performance of 24-h dietary recall (24-HDR) measurements as reference measurements in a linear regression calibration model is evaluated critically at the individual (within-centre) and aggregate (between-centre) levels by using unbiased estimates of urinary measurements of nitrogen and potassium intakes. Methods: Between 1995 and 1999, 1072 study subjects (59% women) from 12 EPIC centres volunteered to collect 24-h urine samples. Log-transformed questionnaire, 24-HDR and urinary measurements of nitrogen and potassium intakes were analysed in a multivariate measurement error model to estimate the validity of coefficients and error correlations in self-reported dietary measurements. In parallel, correlations between means of 24-HDR and urinary measurements were computed. Linear regression calibration models were used to estimate the regression dilution (attenuation) factors. Results: After adjustment for sex, centre, age, body mass index and height, the validity coefficients for 24-HDRs were 0.285 (95% confidence interval: 0.194, 0.367) and 0.371 (0.291, 0.446) for nitrogen and potassium intakes, respectively. The attenuation factors estimated in a linear regression calibration model were 0.368 (0.228, 0.508) for nitrogen and 0.500 (0.361, 0.639) for potassium intakes; only the former was different from the estimate obtained using urinary measurements in the measurement error model. The aggregate-level correlation coefficients between means of urinary and 24-HDR measurements were 0.838 (0.637, 0.932) and 0.756 (0.481, 0.895) for nitrogen and potassium intakes, respectively. Conclusions: This study suggests that 24-HDRs can be used as reference measurements at the individual and aggregate levels for potassium intake, whereas, for nitrogen intake, good performance is observed for between-centre calibration, but some limitations are apparent at the individual level. European Journal of Clinical Nutrition (2009) 63, S179-S187; doi: 10.1038/ejcn.2009.80
  •  
4.
  • Santee, M.L., et al. (författare)
  • Validation of the Aura Microwave Limb Sounder HNO3 Measurements
  • 2007
  • Ingår i: Journal of Geophysical Research. - 0148-0227 .- 2156-2202. ; 112:D24
  • Tidskriftsartikel (refereegranskat)abstract
    • [1] We assess the quality of the version 2.2 (v2.2) HNO(3) measurements from the Microwave Limb Sounder (MLS) on the Earth Observing System Aura satellite. The MLS HNO(3) product has been greatly improved over that in the previous version (v1.5), with smoother profiles, much more realistic behavior at the lowest retrieval levels, and correction of a high bias caused by an error in one of the spectroscopy files used in v1.5 processing. The v2.2 HNO(3) data are scientifically useful over the range 215 to 3.2 hPa, with single-profile precision of similar to 0.7 ppbv throughout. Vertical resolution is 3-4 km in the upper troposphere and lower stratosphere, degrading to similar to 5 km in the middle and upper stratosphere. The impact of various sources of systematic uncertainty has been quantified through a comprehensive set of retrieval simulations. In aggregate, systematic uncertainties are estimated to induce in the v2.2 HNO(3) measurements biases that vary with altitude between +/- 0.5 and +/- 2 ppbv and multiplicative errors of +/- 5-15% throughout the stratosphere, rising to similar to +/- 30% at 215 hPa. Consistent with this uncertainty analysis, comparisons with correlative data sets show that relative to HNO(3) measurements from ground- based, balloon- borne, and satellite instruments operating in both the infrared and microwave regions of the spectrum, MLS v2.2 HNO(3) mixing ratios are uniformly low by 10-30% throughout most of the stratosphere. Comparisons with in situ measurements made from the DC-8 and WB-57 aircraft in the upper troposphere and lowermost stratosphere indicate that the MLS HNO(3) values are low in this region as well, but are useful for scientific studies (with appropriate averaging).
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy