SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Farina Marco) srt2:(2005-2009)"

Sökning: WFRF:(Farina Marco) > (2005-2009)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Pozzo, Marco, et al. (författare)
  • Muscle-fiber conduction velocity during concentric and eccentric actions on a flywheel exercise device
  • 2006
  • Ingår i: Muscle and Nerve. - : Wiley. - 0148-639X .- 1097-4598. ; 34:2, s. 169-177
  • Tidskriftsartikel (refereegranskat)abstract
    • A gravity-independent flywheel exercise device (FWED) has been proven effective as a countermeasure to loss of strength and muscle atrophy induced by simulated microgravity. This study assessed musclefiber conduction velocity (CV) and surface EMG instantaneous mean power spectral frequency (iMNF) during brief bouts of fatiguing concentric (CON) and eccentric (ECC) exercise on a FWED in order to identify electromyographic (EMG) variables that can be used to provide objective indications of muscle status when exercising with a FWED. Multichannel surface EMG signals were recorded from vastus lateralis and medialis muscles of nine men during: (1) isometric, 60-s action at 50% of maximum voluntary action (MVC); (2) two isometric, linearly increasing force ramps (0–100% MVC); and (3) dynamic CON/ECC coupled actions on the FWED. Muscle-fiber CV and iMNF were computed over time during the three tasks. During ramps, CV, but not iMNF, increased with force (P 0.001). Conduction velocity and iMNF decreased with the same normalized rate of change in constant-force actions. During CON/ECC actions, the normalized rate of change over time was larger for CV than iMNF (P 0.05). These results suggest that, during fatiguing, dynamic, variable-force tasks, changes in CV cannot be indirectly inferred by EMG spectral analysis. This underlines the importance of measuring both CV and spectral variables for muscle assessment in dynamic tasks.
  •  
2.
  •  
3.
  • Pozzo, Marco, et al. (författare)
  • Muscle fiber conduction and fatigue during dynamic actions on a flywheel exercise device
  • 2005
  • Ingår i: Journal of Gravitational Physiology. - 1077-9248. ; 12:1, s. 113-114
  • Tidskriftsartikel (refereegranskat)abstract
    • Exposure to microgravity has adverse effects on skeletal muscle size and function. Such effects can be counteracted by training using a Flywheel Exercise Device (FWED). Multichannel EMG signals were detected in nine males from vastus medialis and laterialis muscles during 30 coupled concentric (CON) and eccentric (ECC) actions on the FWED. Muscle fiber conduction velocity (CV) was assessed for each action. CV initial values depended on muscle action type (CON/ECC) and were higher in CON than ECC actions. CV decreased (P<0.05) over time during the task. Its slope was greater for VL than VM but was not different between CON and ECC. It was concluded that direct measure of CV is feasible during dynamic exercise, and that this technique may be used for objective assessment of the effect of resistance training in counteracting microgravity-induced muscle atrophy.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3
Typ av publikation
tidskriftsartikel (2)
konferensbidrag (1)
Typ av innehåll
refereegranskat (3)
Författare/redaktör
Alkner, Björn (3)
Norrbrand, Lena (3)
Pozzo, Marco (3)
Farina, Dario (3)
Tesch, Per A (2)
Tesch, Per (1)
Lärosäte
Kungliga Tekniska Högskolan (3)
Mittuniversitetet (1)
Karolinska Institutet (1)
Språk
Engelska (3)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (3)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy