SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Feldman BM) srt2:(2002-2004)"

Sökning: WFRF:(Feldman BM) > (2002-2004)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Manco-Johnson, MJ, et al. (författare)
  • Physical therapy and imaging outcome measures in a haemophilia population treated with factor prophylaxis: current status and future directions
  • 2004
  • Ingår i: Haemophilia. - : Wiley. - 1351-8216 .- 1365-2516. ; 10, s. 88-93
  • Tidskriftsartikel (refereegranskat)abstract
    • Routine infusions of factor VIII to prevent bleeding, known as prophylaxis, and other intensive therapies are being more broadly applied to patients with haemophilia. These therapies differ widely in replacement product usage, cost, frequency of venous access and parental effort. In order to address residual issues relating to recommendations, implementation, and evaluations of prophylaxis therapy in persons with haemophila, a multinational working group was formed and called the International Prophylaxis Study Group (IPSG). The group was comprised of haemophilia treaters actively involved in studies of prophylaxis from North America and Europe. Two expert committees, the Physical Therapy (PT) Working Group and the Magnetic Resonance Imaging (MRI) Working Group were organized to critically assess existing tools for assessment of Joint outcome. These two committees independently concluded that the WFH Physical Examination Scale (WFH PE Scale) and the WFH X-ray Scale (WFH XR Scale) were inadequately sensitive to detect early changes in Joints. New scales were developed based on suggested modifications of the existing scales and called the Haemophilia joint Health Score (HJHS) and the International MRI Scales. The new scales were piloted. Concordance was measured by the intra-class correlation coefficient of variation. Reliability of the HJHS was excellent with an inter-observer co-efficient of 0.83 and a test-retest value of 0.89. The MRI study was conducted using both Denver and European scoring approaches; inter-reader reliability using the two approaches was 0.88 and 0.87; test-retest reliability was 0.92 and 0.93. These new PT and MRI scales promise to improve outcome assessment in children on early preventive treatment regimens.
  •  
2.
  • Rautaharju, PM, et al. (författare)
  • Comparability of 12-lead ECGs derived from EASI leads with standard 12-lead ECGs in the classification of acute myocardial ischemia and old myocardial infarction
  • 2002
  • Ingår i: Journal of Electrocardiology. - : Elsevier BV. - 1532-8430 .- 0022-0736. ; 35:4, part 2, s. 35-39
  • Tidskriftsartikel (refereegranskat)abstract
    • We compared 12-lead electrocardiograms (ECGs) derived with an improved transformation matrix from EASI leads and standard 12-lead ECGs in the detection of acute myocardial ischemia and old infarction (MI). For the ischemia test, we used ECGs of 40 patients recorded prior to and at peak inflation during percutaneous transluminal coronary angioplasty, and for old MI we used test ECGs of 382 non-MI subjects and of 472 patients with prior MI documented by enzyme findings. Two experienced ECG readers served as separate, independent standards for lead-set comparisons, and the Philips ECG analysis program also classified the ECGs. The results showed no significant differences between the two lead sets in the detection of acute inflation-induced ischemia or of old MI according to coding by the electrocardiographers or the computer program. No significant differences were found between the electrocardiographers and the lead sets for acute ischemia. Classification differences between the electrocardiographers were larger than those between the lead sets for acute and old MI and were significant for the latter (P <.001). A more detailed comparison of the lead sets suggested a possible need for modified old-MI criteria and optimization of ST classification thresholds for acute ischemic injury, specific for the EASI 12-lead ECG. We conclude that the EASI-derived 12-lead ECG deserves serious consideration as an alternative to the standard 12-lead ECG in emergency situations and for monitoring in acute-care setting.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy