SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Fissum S.) srt2:(2010-2014)"

Sökning: WFRF:(Fissum S.) > (2010-2014)

  • Resultat 1-8 av 8
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Erni, W., et al. (författare)
  • Technical design report for the PANDA (AntiProton Annihilations at Darmstadt) Straw Tube Tracker
  • 2013
  • Ingår i: European Physical Journal A. Hadrons and Nuclei. - : Springer Science and Business Media LLC. - 1434-6001 .- 1434-601X. ; 49:2
  • Tidskriftsartikel (refereegranskat)abstract
    • This document describes the technical layout and the expected performance of the Straw Tube Tracker (STT), the main tracking detector of the PANDA target spectrometer. The STT encloses a Micro-Vertex-Detector (MVD) for the inner tracking and is followed in beam direction by a set of GEM stations. The tasks of the STT are the measurement of the particle momentum from the reconstructed trajectory and the measurement of the specific energy loss for a particle identification. Dedicated simulations with full analysis studies of certain proton-antiproton reactions, identified as being benchmark tests for the whole PANDA scientific program, have been performed to test the STT layout and performance. The results are presented, and the time lines to construct the STT are described.
  •  
2.
  • Puckett, A. J. R., et al. (författare)
  • Final analysis of proton form factor ratio data at Q(2)=4.0, 4.8, and 5.6 GeV2
  • 2012
  • Ingår i: Physical Review C (Nuclear Physics). - 0556-2813. ; 85:4
  • Tidskriftsartikel (refereegranskat)abstract
    • Precise measurements of the proton electromagnetic form factor ratio R = mu(p)G(E)(p)/G(M)(p) using the polarization transfer method at Jefferson Lab have revolutionized the understanding of nucleon structure by revealing the strong decrease of R with momentum transfer Q(2) for Q(2) greater than or similar to 1 GeV2, in strong disagreement with previous extractions of R from cross-section measurements. In particular, the polarization transfer results have exposed the limits of applicability of the one-photon-exchange approximation and highlighted the role of quark orbital angular momentum in the nucleon structure. The GEp-II experiment in Jefferson Lab's Hall A measured R at four Q(2) values in the range 3.5 GeV2 <= Q(2) <= 5.6 GeV2. A possible discrepancy between the originally published GEp-II results and more recent measurements at higher Q(2) motivated a new analysis of the GEp-II data. This article presents the final results of the GEp-II experiment, including details of the new analysis, an expanded description of the apparatus, and an overview of theoretical progress since the original publication. The key result of the final analysis is a systematic increase in the results for R, improving the consistency of the polarization transfer data in the high-Q(2) region. This increase is the result of an improved selection of elastic events which largely removes the systematic effect of the inelastic contamination, underestimated by the original analysis.
  •  
3.
  • Myers, L. S., et al. (författare)
  • Compton scattering from C-12 using tagged photons in the energy range 65-115 MeV
  • 2014
  • Ingår i: Physical Review C (Nuclear Physics). - 0556-2813. ; 89:3
  • Tidskriftsartikel (refereegranskat)abstract
    • Elastic scattering of photons from C-12 has been investigated using quasimonoenergetic tagged photons with energies in the range 65-115 MeV at laboratory angles of 60 degrees, 120 degrees, and 150 degrees. at the Tagged-Photon Facility at the MAX IV Laboratory in Lund, Sweden. A phenomenological model was employed to provide an estimate of the sensitivity of the C-12(gamma,gamma)C-12 cross section to the bound- nucleon polarizabilities.
  •  
4.
  • Myers, L S, et al. (författare)
  • Measurement of compton scattering from the deuteron and an improved extraction of the neutron electromagnetic polarizabilities.
  • 2014
  • Ingår i: Physical Review Letters. - 1079-7114. ; 113:26
  • Tidskriftsartikel (refereegranskat)abstract
    • The electromagnetic polarizabilities of the nucleon are fundamental properties that describe its response to external electric and magnetic fields. They can be extracted from Compton-scattering data-and have been, with good accuracy, in the case of the proton. In contradistinction, information for the neutron requires the use of Compton scattering from nuclear targets. Here, we report a new measurement of elastic photon scattering from deuterium using quasimonoenergetic tagged photons at the MAX IV Laboratory in Lund, Sweden. These first new data in more than a decade effectively double the world data set. Their energy range overlaps with previous experiments and extends it by 20 MeV to higher energies. An analysis using chiral effective field theory with dynamical Δ(1232) degrees of freedom shows the data are consistent with and within the world data set. After demonstrating that the fit is consistent with the Baldin sum rule, extracting values for the isoscalar nucleon polarizabilities, and combining them with a recent result for the proton, we obtain the neutron polarizabilities as α_{n}=[11.55±1.25(stat)±0.2(BSR)±0.8(th)]×10^{-4} fm^{3} and β_{n}=[3.65∓1.25(stat)±0.2(BSR)∓0.8(th)]×10^{-4} fm^{3}, with χ^{2}=45.2 for 44 degrees of freedom.
  •  
5.
  • Kirstein, Oliver, et al. (författare)
  • Neutron position sensitive detectors for the ESS
  • 2014
  • Ingår i: Proceedings of Science. - : Proceedings of Science (PoS). ; Vertex2014, s. 029-029
  • Konferensbidrag (refereegranskat)abstract
    • The European Spallation Source (ESS) in Lund, Sweden will become the world's leading neutron source for the study of materials. It will be a long pulse source, with an average beam power of 5 MW delivered to the target station. The ESS is in the construction phase, which started in 2013 with the completion of the Technical Design Report (TDR). The instruments are being selected from conceptual proposals submitted by groups from around Europe. These instruments present numerous challenges for detector technology in the absence of the availability of Helium-3, which is the default choice for detectors for instruments built until today and due to the extreme rates expected across the ESS instrument suite. Additionally a new generation of source requires a new generation of detector technologies to fully exploit the opportunities that this source provides. To meet this challenge at a green-field site, the detectors will be sourced from partners across Europe through numerous in-kind arrangements; a process that is somewhat novel for the neutron scattering community. This contribution presents briefly the current status of detectors for the ESS, and outlines the timeline to completion. For a conjectured instrument suite based upon instruments recommended for construction, a recently updated snapshot of the current expected detector requirements is presented. A strategy outline as to how these requirements might be tackled by novel detector developments is shown. In terms of future developments for the neutron community, synergies should be sought with other disciples, as recognized by various recent initiatives in Europe, in the context of the fundamentally multi-disciplinary nature of detectors. This strategy has at its basis the in-kind and collaborative partnerships necessary to be able to produce optimally performant detectors that allow the ESS instruments to be world-leading. This foresees and encourages a high level of collaboration and interdependence at its core, and rather than each group being all-rounders in every technology, the further development of centres of excellence across Europe for particular technologies and niches.
  •  
6.
  • Margaryan, Ashot, et al. (författare)
  • Low-Pressure MWPC System for the detection of Alpha-Particles and Fission Fragments
  • 2010
  • Ingår i: Armenian Journal of Physics. - 1829-1171. ; 3:4, s. 282-291
  • Tidskriftsartikel (refereegranskat)abstract
    • A low-pressure, position-sensitive, multi-wire proportional chamber (LPMWPC) system with an active area 12×12 cm 2 for the detection of heavy nuclear fragments, has been developed for use in tagged photon beam experiments. The LPMWPC system can be operated in single as well as double step operational modes. In the case of double step operational mode with a high gas amplification factor, signals from α-particles reside well above the electronic noise. Typical energy loss spectra of alpha particles and fission fragments (FF) obtained from a 252 Cf source are shown and discussed. The pulse height distributions of α-particles have a Landau distribution shape, while the pulse height distribution of FFs differs from Gaussian shape. It has long tails at both low-and high-energy sides. The average pulse height ratio of alpha particles and FF's is close to the theoretical value and amounts to about 1/80.
  •  
7.
  • Myers, L. S., et al. (författare)
  • Monte Carlo simulation of the photon-tagger focal-plane electronics at the MAX IV laboratory
  • 2013
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - : Elsevier BV. - 0167-5087 .- 0168-9002. ; 729, s. 707-717
  • Tidskriftsartikel (refereegranskat)abstract
    • Rate-dependent effects in the electronics used to instrument the tagger focal plane at the MAX IV Laboratory have been investigated using the novel approach of Monte Carlo simulation. Results are compared to analytical calculations as well as experimental data for both specialized testing and production running to demonstrate a thorough understanding of the behavior of the detector system.(C) 2013 Elsevier By. All rights reserved.
  •  
8.
  • Preston, M. F., et al. (författare)
  • Tests of the Monte Carlo Simulation of the Photon-Tagger Focal-Plane Electronics at the MAX IV Laboratory
  • 2014
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - : Elsevier BV. - 0167-5087 .- 0168-9002. ; 744, s. 17-17
  • Tidskriftsartikel (refereegranskat)abstract
    • Rate-dependent effects in the electronics used to instrument the tagger focal plane at the MAX IV Laboratory were recently investigated using the novel approach of Monte Carlo simulation to allow for normalization of high-rate experimental data acquired with single-hit time-to-digital converters (TDCs). The instrumentation of the tagger focal plane has now been expanded to include multi-hit TDCs. The agreement between results obtained from data taken using single-hit and multi-hit TDCs demonstrate a thorough understanding of the behavior of the detector system.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-8 av 8

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy