SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Forstner A J) srt2:(2005-2009)"

Sökning: WFRF:(Forstner A J) > (2005-2009)

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Niedermaier, O., et al. (författare)
  • "Safe" Coulomb excitation of Mg-30
  • 2005
  • Ingår i: Physical Review Letters. - 1079-7114 .- 0031-9007. ; 94:17, s. 172501 (artno)-
  • Tidskriftsartikel (refereegranskat)abstract
    • We report on the first radioactive beam experiment performed at the recently commissioned REX-ISOLDE facility at CERN in conjunction with the highly efficient γ spectrometer MINIBALL. Using Mg-30 ions accelerated to an energy of 2.25 MeV/u together with a thin Ni-nat target, Coulomb excitation of the first excited 2(+) states of the projectile and target nuclei well below the Coulomb barrier was observed. From the measured relative deexcitation γ-ray yields the B(E2;0(gs)(+)→ 2(1)(+)) value of Mg-30 was determined to be 241(31)e(2) fm(4). Our result is lower than values obtained at projectile fragmentation facilities using the intermediate-energy Coulomb excitation method, and confirms the theoretical conjecture that the neutron-rich magnesium isotope Mg-30 resides outside the "island of inversion."
  •  
2.
  • Niedermaier, O., et al. (författare)
  • The neutron-rich Mg isotopes: first results from MINIBALL at REX-ISOLDE
  • 2005
  • Ingår i: Nuclear Physics A. - : Elsevier BV. - 0375-9474. ; 752, s. 273-273
  • Tidskriftsartikel (refereegranskat)abstract
    • We report on the first radioactive beam experiment performed at the recently commissioned REX-ISOLDE facility at CERN in conjunction with the highly efficient γ spectrometer MINIBALL. Using Mg-30 ions accelerated to an energy of 2.25 MeV/u together with a thin Ni-nat target, Coulomb excitation of the first excited 2(+) states of the projectile and target nuclei well below the Coulomb barrier was observed. From the measured relative deexcitation γ-ray yields the B(E2;0(gs)(+)→ 2(1)(+)) value of Mg-30 was determined to be 241(31)e(2) fm(4). Our result is lower than values obtained at projectile fragmentation facilities using the intermediate-energy Coulomb excitation method, and confirms the theoretical conjecture that the neutron-rich magnesium isotope Mg-30 resides outside the "island of inversion."
  •  
3.
  • Scheit, H., et al. (författare)
  • Coulomb excitation of neutron-rich beams at REX-ISOLDE
  • 2005
  • Ingår i: European Physical Journal A. - : Springer Science and Business Media LLC. - 1434-601X .- 1434-6001. ; 25:Suppl. 1, s. 397-402
  • Konferensbidrag (refereegranskat)abstract
    • After the successful commissioning of the radioactive beam experiment at ISOLDE (REX-ISOLDE) - an accelerator for exotic nuclei produced by ISOLDE - in 2002 and the promotion to a CERN user facility in 2003, first physics experiments using these beams were performed. Initial experiments focused on the region of deformation in the vicinity of the neutron-rich Na and Mg isotopes. Preliminary results on the neutron-rich Na and Mg isotopes show the high potential and physics opportunities offered by the exotic isotope accelerator REX in conjunction with the modern Germanium gamma spectrometer MINIBALL.
  •  
4.
  • Jeppesen, H. B., et al. (författare)
  • Investigation of the Li-9+H-2 -> Li-8+t reaction at REX-ISOLDE
  • 2006
  • Ingår i: Physics Letters, Section B: Nuclear, Elementary Particle and High-Energy Physics. - : Elsevier BV. - 0370-2693. ; 635, s. 17-17
  • Tidskriftsartikel (refereegranskat)abstract
    • The one-neutron transfer reaction Li-9 + H-2 -> Li-8 + t has been investigated in an inverse kinematics experiment by bombarding a deuterated polypropylene target with a 2.36 MeV/u Li-9 beam from the post-accelerator REX-ISOLDE at CERN. Excitation energies in Li-8 as well as angular distributions of the tritons were obtained and spectroscopic factors deduced. (c) 2006 Elsevier B.V. All rights reserved.
  •  
5.
  • Jeppesen, H. B., et al. (författare)
  • Low energy reactions with radioactive ions at REX-ISOLDE - the Li-9+H-2 case
  • 2005
  • Ingår i: Nuclear Physics A. - : Elsevier BV. - 0375-9474. ; 748, s. 374-374
  • Tidskriftsartikel (refereegranskat)abstract
    • At the newly constructed postaccelerator REX-ISOLDE (Radioactive beam Experiment at ISOLDE) we have investigated reactions induced by a Li-9 beam incident on a deuterium target at an energy of 2.36 MeV/u. Most reaction channels were recorded. From one-neutron transfer the differential cross-section for the low lying Li-10 spectrum is found. The results from the other channels demonstrate the great applicability and many possibilities that REX-ISOLDE opens up.
  •  
6.
  • Kinkel, K., et al. (författare)
  • Staging of endometrial cancer with MRI : Guidelines of the European Society of Urogenital Imaging
  • 2009
  • Ingår i: European Radiology. - : Springer Science and Business Media LLC. - 0938-7994 .- 1432-1084. ; 19:7, s. 1565-1574
  • Tidskriftsartikel (refereegranskat)abstract
    • The purpose of this study was to define guidelines for endometrial cancer staging with MRI. The technique included critical review and expert consensus of MRI protocols by the female imaging subcommittee of the European Society of Urogenital Radiology, from ten European institutions, and published literature between 1999 and 2008. The results indicated that high field MRI should include at least two T2-weighted sequences in sagittal, axial oblique or coronal oblique orientation (short and long axis of the uterine body) of the pelvic content. High-resolution post-contrast images acquired at 2 min +/- 30 s after intravenous contrast injection are suggested to be optimal for the diagnosis of myometrial invasion. If cervical invasion is suspected, additional slice orientation perpendicular to the axis of the endocervical channel is recommended. Due to the limited sensitivity of MRI to detect lymph node metastasis without lymph node-specific contrast agents, retroperitoneal lymph node screening with pre-contrast sequences up to the level of the kidneys is optional. The likelihood of lymph node invasion and the need for staging lymphadenectomy are also indicated by high-grade histology at endometrial tissue sampling and by deep myometrial or cervical invasion detected by MRI. In conclusion, expert consensus and literature review lead to an optimized MRI protocol to stage endometrial cancer.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy