Sökning: WFRF:(Gascon D)
> (1995-1999) >
Performance of two ...
Performance of two immunoassays for the determination of atrazine in sea water samples as compared with on-line solid phase extraction-liquid chromatography-diode array detection
-
- Gascón, Jordi (författare)
- CSIC Centro de Investigación y Desarrollo Pascual Vila (CID)
-
- Oubiña, Anna (författare)
- CSIC Centro de Investigación y Desarrollo Pascual Vila (CID)
-
- Ferrer, Imma (författare)
- CSIC Centro de Investigación y Desarrollo Pascual Vila (CID)
-
visa fler...
-
- Önnerfjord, Patrik (författare)
- Lund University,Lunds universitet,Reumatologi och molekylär skelettbiologi,Sektion III,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Rheumatology,Section III,Department of Clinical Sciences, Lund,Faculty of Medicine,CSIC Centro de Investigación y Desarrollo Pascual Vila (CID)
-
- Marko-Varga, György (författare)
- Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH,Department of Clinical Sciences, Lund,Faculty of Medicine
-
- Hammock, Bruce D. (författare)
- University of California, Davis
-
- Marco, Maria Pilar (författare)
- CSIC Centro de Investigación y Desarrollo Pascual Vila (CID)
-
- Barceló, Damià (författare)
- CSIC Centro de Investigación y Desarrollo Pascual Vila (CID)
-
visa färre...
-
(creator_code:org_t)
- Elsevier BV, 1996
- 1996
- Engelska.
-
Ingår i: Analytica Chimica Acta. - : Elsevier BV. - 0003-2670. ; 330:1, s. 41-51
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Two immunoassay formats, magnetic particles-based assay (Atrazine RaPID assay and Atrazine High-Sensitivity RaPID assay) and microtiter plate based assay (Department of Entomology and Environmental Toxicology, University of California in Davis) were evaluated for the determination of atrazine in sea water samples. The results obtained were compared and validated with those obtained by using on-line solid phase extraction followed by liquid chromatography-diode array detection (on-line SPE-LC-DAD). The correlation between both techniques was good when analyzing levels of atrazine ranging from 0.01 to 5 μg/l in samples showing salt concentration values varying from 0 to 35 g/l and pH values from 2 to 10. One of these immunoassays (Atrazine High-Sensitivity RaPID assay) was employed to directly analyze atrazine in real estuarine and coastal water samples. The same samples were analyzed after filtration and C18 Empore disks extraction.
Nyckelord
- Atrazine
- Chromatography
- Immunoassay
- Sea water
- Solid-phase extraction
- Waters
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas