SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Gatty Hithesh K.) srt2:(2015-2019)"

Sökning: WFRF:(Gatty Hithesh K.) > (2015-2019)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Cavallaro, Sara, et al. (författare)
  • Label-Free Surface Protein Profiling of Extracellular Vesicles by an Electrokinetic Sensor
  • 2019
  • Ingår i: ACS Sensors. - : AMER CHEMICAL SOC. - 2379-3694. ; 4:5, s. 1399-1408
  • Tidskriftsartikel (refereegranskat)abstract
    • Small extracellular vesicles (sEVs) generated from the endolysosomal system, often referred to as exosomes, have attracted interest as a suitable biomarker for cancer diagnostics, as they carry valuable biological information and reflect their cells of origin. Herein, we propose a simple and inexpensive electrical method for label-free detection and profiling of sEVs in the size range of exosomes. The detection method is based on the electrokinetic principle, where the change in the streaming current is monitored as the surface markers of the sEVs interact with the affinity reagents immobilized on the inner surface of a silica microcapillary. As a proof-of-concept, we detected sEVs derived from the non-small-cell lung cancer (NSCLC) cell line H1975 for a set of representative surface markers, such as epidermal growth factor receptor (EGFR), CD9, and CD63. The detection sensitivity was estimated to be similar to 175000 sEVs, which represents a sensor surface coverage of only 0.04%. We further validated the ability of the sensor to measure the expression level of a membrane protein by using sEVs displaying artificially altered expressions of EGFR and CD63, which were derived from NSCLC and human embryonic kidney (HEK) 293T cells, respectively. The analysis revealed that the changes in EGFR and CD63 expressions in sEVs can be detected with a sensitivity in the order of 10% and 3%, respectively, of their parental cell expressions. The method can be easily parallelized and combined with existing microfluidic-based EV isolation technologies, allowing for rapid detection and monitoring of sEVs for cancer diagnosis.
  •  
2.
  • Gatty, Hithesh K., et al. (författare)
  • A Miniaturized Amperometric Hydrogen Sulfide Sensor Applicable for Bad Breath Monitoring
  • 2018
  • Ingår i: Micromachines. - : MDPI. - 2072-666X. ; 9:12
  • Tidskriftsartikel (refereegranskat)abstract
    • Bad breath or halitosis affects a majority of the population from time to time, causing personal discomfort and social embarrassment. Here, we report on a miniaturized, microelectromechanical systems (MEMS)-based, amperometric hydrogen sulfide (H2S) sensor that potentially allows bad breath quantification through a small handheld device. The sensor is designed to detect H2S gas in the order of parts-per-billion (ppb) and has a measured sensitivity of 0.65 nA/ppb with a response time of 21 s. The sensor was found to be selective to NO and NH3 gases, which are normally present in the oral breath of adults. The ppb-level detection capability of the integrated sensor, combined with its relatively fast response and high sensitivity to H2S, makes the sensor potentially applicable for oral breath monitoring.
  •  
3.
  • Gatty, Hithesh K., et al. (författare)
  • An amperometric nitric oxide sensor with fast response and ppb-level concentration detection relevant to asthma monitoring
  • 2015
  • Ingår i: Sensors and actuators. B, Chemical. - : Elsevier BV. - 0925-4005 .- 1873-3077. ; 209, s. 639-644
  • Tidskriftsartikel (refereegranskat)abstract
    • A MEMS-based amperometric nitric oxide (NO) gas sensor is reported in this paper. The sensor is designed to detect NO gas for the purpose of asthma monitoring. The unique property of this sensor lies in the combination of a microporous high-surface area electrode that is coated with Nafion (TM), together with a liquid electrolyte. The sensor is able to detect gas concentrations of the order of parts-per-billion (ppb) and has a measured NO sensitivity of 0.045 nA/ppb and an operating range between 25 and 65% relative humidity. The settling time of the sensor is measured to 8s. The selectivity to interfering gases such as ammonia (NH3) and carbon monoxide (CO) was high when placing an activated carbon fiber filter above the sensor. The ppb-level detection capability of this sensor combined with its relatively fast response, high selectivity to CO and NH3 makes the sensor potentially applicable in gas monitoring for asthma detection.
  •  
4.
  • Gatty, Hithesh K, 1980- (författare)
  • MEMS-based electrochemical gas sensors and wafer-level methods
  • 2015
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • This thesis describes novel microel ectromechanical system (MEMS) based electrochemical gas sensors and methods of fabrication.This thesis presents the research in two parts. In the first part, a method to handle a thin silicon wafer using an electrochemically active adhesive is described. Handling of a thin silicon wafer is an important issue in 3D-IC manufacturing where through silicon vias (TSVs) is an enabling technology. Thin silicon wafers are flexible and fragile, therefore difficult to handle. In addressing the need for a reliable solution, a method based on an electrochemically active adhesive was developed. In this method, an electrochemically active adhesive was diluted and spin coated on a 100 mm diameter silicon wafer (carrier wafer) on which another silicon wafer (device wafer) was bonded. Device wafer was subjected to post processing fabrication technique such as wafer thinning. Successful debonding of the device wafer was achieved by applying a voltage between the two wafers. In another part of the research, a fabrication process for developing a functional nanoporous material using atomic layer deposition is presented. In order to realize a nanoporous electrode, a nanoporous anodized aluminum oxide (AAO) substrate was used, which was functionalized with very thin layers (~ 10 nm) of platinum (Pt) and aluminum oxide (Al2O3) using atomic layer deposition. Nanoporous material when used as an electrode delivers high sensitivity due to the inherent high surface area and is potentially applicable in fuel cells and in electrochemical sensing.The second part of the thesis addresses the need for a high performance gas sensor that is applicable for asthma monitoring. Asthma is a disease related to the inflammation in the airways of the lungs and is characterized by the presence of nitric oxide gas in the exhaled breath. The gas concentration of above approximately 50 parts-per-billion indicates a likely presence of asthma. A MEMS based electrochemical gas sensor was successfully designed and developed to meet the stringent requirements needed for asthma detection. Furthermore, to enable a hand held asthma measuring instrument, a miniaturized sensor with integrated electrodes and liquid electrolyte was developed. The electrodes were assembled at a wafer-level to demonstrate the feasibility towards a high volume fabrication of the gas sensors. In addition, the designed amperometric gas sensor was successfully tested for hydrogen sulphide concentration, which is a bio marker for bad breath.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy