1.
  • Eriksson, Jacob, et al. (författare)
  • Finite Larmor radii effects in fast ion measurements as demonstrated using neutron emission spectrometry of JET plasmas heated with 3rd harmonic ICRF
  • 2011
  • Ingår i: 38th EPS Conference on Plasma Physics 2011 (EPS 2011): Europhysics Conference Abstracts. - 2914771681
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)abstract
    • This paper demonstrates how the finite Larmor radii (FLR) of fast ions can affect fast ion measurements by studying data from the neutron time-of-flight spectrometer TOFOR. Neutron spectra were calculated from a model of the fast ion velocity distribution for a JET experiment with 3rd harmonic ICRF heating of deuterium beams. It was found that  FLR effects need to be considered to get a good description of the data,  if the Larmor radius of the fast ions are comparable to the width of the field of view of the instrument. This applies not only to results from neutron spectrometry but also to other types of fast ion diagnostics.
  •  
2.
  • Moro, F., et al. (författare)
  • Neutronic calculations in support of the design of the ITER High Resolution Neutron Spectrometer
  • 2011
  • Ingår i: Fusion engineering and design. - : Elsevier BV. - 0920-3796 .- 1873-7196. ; 86:6-8, s. 1277-1281
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper presents the results of neutronic calculations performed to address important issues related to the optimization of the ITER HRNS (High resolution Neutron Spectrometer) design, in particular concerning the definition of the collimator and the choice of the detector system. The calculations have been carried out using the MCNP5 Monte Carlo code in a full 3-D geometry. The HRNS collimation system has been included in the latest MCNP ITER 40 model (Alite-4). The ITER scenario 2 reference DT plasma fusion neutron source peaked at 14.1 MeV with Gaussian energy distribution has been used. Neutron fluxes and energy spectra (>1 MeV) have been evaluated at different positions along the HRNS collimator and at the detector location. The noise-to-signal ratio (i.e. the ratio of collided to uncoilided neutrons), the breakdown of the collided spectrum into its components, the dependency on the first wall aperture and the gamma-ray spectra at the detector position have also been analyzed. The impact of the results on the design of the HRNS diagnostic system is discussed.
  •  