1.
  • Alshamari, Muhammed, 1975-, et al. (författare)
  • Low-dose computed tomography of the lumbar spine: a phantom study on imaging parameters and image quality
  • 2014
  • Ingår i: Acta Radiologica. - : SAGE Publications. - 1600-0455 .- 0284-1851. ; 55:7, s. 824-832
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Lumbar spine radiography has limited diagnostic value but low radiation dose compared with computed tomography (CT). The average effective radiation dose from lumbar spine radiography is about 1.1 mSv. Low-dose lumbar spine CT may be an alternative to increase the diagnostic value at low radiation dose, around 1 mSv. Purpose: To determine the optimal settings for low-dose lumbar spine CT simultaneously aiming for the highest diagnostic image quality possible. Material and Methods: An ovine lower thoracic and lumbar spine phantom, with all soft tissues around the vertebrae preserved except the skin, was placed in a 20 L plastic container filled with water. The phantom was scanned repeatedly with various technical settings; different tube potential, reference mAs, and with different convolution filters. Five radiologists evaluated the image quality according to a modification of the European guidelines for multislice computed tomography (MSCT) quality criteria for lumbar spine CT 2004. In a visual comparison the different scans were also ranked subjectively according to perceived image quality. Image noise and contrast were measured. Results: A tube potential of 120 kV with reference mAs 30 and medium or medium smooth convolution filter gave the best image quality at a sub-millisievert dose level, i.e. with an effective dose comparable to that from lumbar spine radiography. Conclusion: Low-dose lumbar spine CT thus opens a possibility to substitute lumbar spine radiography with CT without obvious increase in radiation dose.
  •  
2.
  • Geijer, Håkan, 1961-, et al. (författare)
  • Somatostatin receptor PET/CT in neuroendocrine tumours : update on systematic review and meta-analysis
  • 2013
  • Ingår i: European Journal of Nuclear Medicine and Molecular Imaging. - : Springer. - 1619-7070 .- 1619-7089. ; 40:11, s. 1770-1780
  • Forskningsöversikt (refereegranskat)abstract
    • Purpose Neuroendocrine tumours (NET) are uncommon and may be localized in many different places in the body. Traditional imaging has mainly been performed with CT and somatostatin receptor scintigraphy (SRS). Recently, it has become possible to use somatostatin receptor PET/CT (SMSR PET) instead, which might improve diagnostic quality. To evaluate the diagnostic quality of SMSR PET we performed a meta-analysis as an update of a previous study published in 2012. A literature search was performed searching MEDLINE, Embase and five other databases with a combination of the expressions "PET", "positron emission tomography", "neuroendocrine" and "NET". The search was updated to 31 December 2012. Studies were selected which evaluated the sensitivity and specificity of SMSR PET for NET in the thorax or abdomen with a study size of at least eight patients. The methodological quality of the included studies was evaluated with QUADAS-2. Eight studies fulfilled the inclusion criteria and were selected for final analysis, and 14 articles from a previous meta-analysis were added for a total of 22 articles. A total of 2,105 patients were included in the studies, an increase from 567 in the previous meta-analysis. The pooled sensitivity was 93 % (95 % CI 91 - 94 %) and specificity 96 % (95 % CI 95 - 98 %). The area under the summary ROC curve was 0.98 (95 % CI 0.95 - 1.0). In the previous meta-analysis the pooled sensitivity was 93 % (95 % CI 91 - 95 %) and specificity 91 % (95 % CI 82 - 97 %). SMSR PET has good diagnostic performance for evaluation of NET in the thorax and abdomen, better than SRS which has been the previous standard method. This meta-analysis gives further support for switching to SMSR PET.
  •  
3.
  • Johansson, Benny L., et al. (författare)
  • Slower progression of atherosclerosis in vein grafts harvested with 'no touch' technique compared with conventional harvesting technique in coronary artery bypass grafting : an angiographic and intravascular ultrasound study
  • 2010
  • Ingår i: European Journal of Cardio-Thoracic Surgery. - : Oxford University Press (OUP). - 1010-7940 .- 1873-734X. ; 38:4, s. 414-419
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: In a long-term randomised coronary artery bypass grafting (CABG) study, the patency rate using a new 'no touch' (NT) vein-graft preparation technique was superior to the conventional (C) technique. This cineangiographic and intravascular ultrasound (IVUS) substudy examined possible mechanisms.Methods: A total of 45 patients (118 grafts) in the NT group and 46 patients (112 grafts) in the C group had patent grafts at short-term follow-up after 18 months. Thirty-seven patients (91 grafts) in the NT group and 37 patients (77 grafts) in the C group had patent grafts at long-term follow-up after 8 5 years, and were evaluated on a scale from 0 (normal) to 2 (significant stenosis) by cineangiogram. IVUS was performed in 15 NT grafts and 14 C grafts in the short-term follow-up, and 27 NT grafts and 26 C grafts in the long-term follow-up, in grafts considered normal by the cineangiogram. The grafts were evaluated with respect to lumen volume, intimal thickness, incidence of plaque and plaque components.Results: In the short-term follow-up, the cineangiogram showed more normal grafts (89.0% in the NT group compared with 75.0% in the C group), and the number of grafts with stenosis was 11.0% in the NT group compared with 25.0% in the C group (p = 0.006). IVUS showed less mean intimal thickness (0.43 (0.07) mm vs 0.52 (0.08) mm; p = 0.03), less grafts with considerable intimal hyperplasia (>= 0.9 mm; 20% vs 78.6%; p = 0.011) and fewer patients with considerable hyperplasia (>= 0.9 mm; 25% vs 100%; p = 0.007). In the long-term follow-up, the cineangiogram showed more normal grafts, with 91.2% in the NT group compared with 83.1% in the C group; there were fewer grafts with significant stenosis, with 7.7% in the NT group compared with 15 6% in the C group (p = 0.14). IVUS showed fewer grafts containing multiple plaques (14.8% vs 50%; p = 0.008), less advanced plaque with lipid (11.8% vs 63.9%; p = 0.0004) and less maximal plaque thickness (1.04 (0.23) mm vs 1.32 (0.25) mm; p = 0.02) in the NT group compared with the C group.Conclusion: The superior long-term patency rate using the NT vein-graft technique at CABG could be explained by a significantly slower progression of atherosclerosis. (C) 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
  •  
4.
  • Lidén, Mats, 1976-, et al. (författare)
  • Urinary stone size estimation : a new segmentation algorithm-based CT method
  • 2012
  • Ingår i: European Radiology. - New York, USA : Springer. - 0938-7994 .- 1432-1084. ; 22:4, s. 731-737
  • Tidskriftsartikel (refereegranskat)abstract
    • The size estimation in CT images of an obstructing ureteral calculus is important for the clinical management of a patient presenting with renal colic. The objective of the present study was to develop a reader independent urinary calculus segmentation algorithm using well-known digital image processing steps and to validate the method against size estimations by several readers. Fifty clinical CT examinations demonstrating urinary calculi were included. Each calculus was measured independently by 11 readers. The mean value of their size estimations was used as validation data for each calculus. The segmentation algorithm consisted of interpolated zoom, binary thresholding and morphological operations. Ten examinations were used for algorithm optimisation and 40 for validation. Based on the optimisation results three segmentation method candidates were identified. Between the primary segmentation algorithm using cubic spline interpolation and the mean estimation by 11 readers, the bias was 0.0 mm, the standard deviation of the difference 0.26 mm and the Bland-Altman limits of agreement 0.0 +/- 0.5 mm. The validation showed good agreement between the suggested algorithm and the mean estimation by a large number of readers. The limit of agreement was narrower than the inter-reader limit of agreement previously reported for the same data. The size of kidney stones is usually estimated manually by the radiologist. An algorithm for computer-aided size estimation is introduced. The variability between readers can be reduced. A reduced variability can give better information for treatment decisions.
  •  
5.
  • Lundin, Margareta, et al. (författare)
  • Virtual non-contrast dual-energy CT compared to single-energy CT of the urinary tract : a prospective study
  • 2012
  • Ingår i: Acta Radiologica. - : Informa Healthcare. - 0284-1851 .- 1600-0455. ; 53:6, s. 689-694
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Dual-energy computed tomography (DECT) has been shown to be useful for subtracting bone or calcium in CT angiography and gives an opportunity to produce a virtual non-contrast-enhanced (VNC) image from a series where contrast agents have been given intravenously. High noise levels and low resolution have previously limited the diagnostic value of the VNC images created with the first generation of DECT. With the recent introduction of a second generation of DECT, there is a possibility of obtaining VNC images with better image quality at hopefully lower radiation dose compared to the previous generation.Purpose: The aim of this study is to compare the image quality of the single-energy series to a VNC series obtained with a two generations of DECT scanners. CT of the urinary tract was used as a model.Material and Methods: Thirty patients referred for evaluation of haematuria were examined with an older system (Somatom Definition) and another 30 patients with a new generation (Somatom Definition Flash). One single-energy series was obtained before and one dual-energy series after administration of intravenous contrast media. We created a VNC series from the contrast-enhanced images. Images were assessed concerning image quality with a visual grading scale evaluation of the VNC series with the single-energy series as gold standard.Results: The image quality of the VNC images was rated inferior to the single-energy variant for both scanners, OR range 11.5-67.3 for the Definition and OR 2.1-2.8 for the Definition Flash. Visual noise and overall quality were regarded as better with Flash than Definition.Conclusions: Image quality of VNC images obtained with the new generation of DECT is still slightly inferior compared to native images. However the difference is smaller with the new compared to the older system.
  •  
6.
  • Savilampi, Johanna, 1977-, et al. (författare)
  • Aspiration Induced by Remifentanil : A Double-blind, Randomized, Crossover Study in Healthy Volunteers
  • 2014
  • Ingår i: Anesthesiology. - : Lippincott Williams & Wilkins. - 0003-3022 .- 1528-1175. ; 121:1, s. 52-58
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Remifentanil is widely used for monitored anesthesia care in spontaneously breathing patients. However, the authors' previous studies have shown that remifentanil induces subjective swallowing difficulties, which may increase the risk of aspiration.Methods: Twenty-five healthy volunteers participated in a double-blind, randomized, crossover trial at the University Hospital in orebro, orebro, Sweden. The volunteers were studied on two different occasions during which they received either remifentanil with an effect-site target concentration of 3 ng/ml or saline over 1 h. A radionuclide tracer was infused simultaneously into the nasopharynx at a rate of 0.1 ml/min. Aspiration was determined by lung scans, and subjective swallowing difficulties and grip strength were evaluated. The primary outcome was the difference in occurrence of aspiration between remifentanil and placebo treatments. The secondary outcomes were differences in swallowing difficulty and grip strength and the association between aspiration and swallowing difficulty.Results: During remifentanil and placebo infusion, 48 and 12% of the volunteers aspirated, respectively, difference: 36% (95% CI, 10 to 62%). A similar significant difference was found for swallowing difficulties but not for the association between aspiration and swallowing. No difference was found in grip strength between the two treatments.Conclusions: Remifentanil infusion at concentrations used in monitored anesthesia care increases the incidence of aspiration. However, the subjective swallowing difficulty induced by remifentanil is not indicative of the aspiration risk.
  •  