SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Giannitsis E.) srt2:(2015-2019)"

Sökning: WFRF:(Giannitsis E.) > (2015-2019)

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Boeddinghaus, Jasper, et al. (författare)
  • Impact of age on the performance of the ESC 0/1h-algorithms for early diagnosis of myocardial infarction
  • 2018
  • Ingår i: European Heart Journal. - : OXFORD UNIV PRESS. - 0195-668X .- 1522-9645. ; 39:42, s. 3780-3794
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims We aimed to evaluate the impact of age on the performance of the European Society of Cardiology (ESC) 0/1h-algorithms and to derive and externally validate alternative cut-offs specific to older patients. Methods and results We prospectively enrolled patients presenting to the emergency department (ED) with symptoms suggestive of and results acute myocardial infarction in three large diagnostic studies. Final diagnoses were adjudicated by two independent cardiologists. High-sensitivity cardiac troponin (hs-cTn) T and I concentrations were measured at presentation and after 1 h. Patients were stratified according to age [<55 years (young), >= 55 to <70 years (middle-age), >= 70 years (old)]. Rule-out safety of the ESC hs-cTnT 0/1h-algorithm was very high in all age-strata: sensitivity 100% [95% confidence interval (95% CI) 94.9-100] in young, 99.3% (95% CI 96.0-99.9) in middle-age, and 99.3% (95% CI 97.599.8) in old patients. Accuracy of rule-in decreased with age: specificity 97.0% (95% CI 95.8-97.9) in young, 96.1% (95% CI 94.5-97.2) in middle-age, and 92.7% (95% CI 90.7-94.3) in older patients. Triage efficacy decreased with increasing age (young 93%, middle-age 80%, old 55%, P <0.001). Similar results were found for the ESC hs-cTnT 0/1h-algorithm. Alternative, slightly higher cut-off concentrations optimized for older patients maintained very high safety of rule-out, increased specificity of rule-in (P< 0.01), reduced overall efficacy for hs-cTnT (P <0.01), while maintaining efficacy for hs-cTnl. Findings were confirmed in two validation cohorts (n = 2767). Conclusion While safety of the ESC 0/1h-algorithms remained very high, increasing age significantly reduced overall efficacy and the accuracy of rule-in. Alternative slightly higher cut-off concentrations may be considered for older patients, particularly if using hs-cTnl.
  •  
3.
  • Mair, J., et al. (författare)
  • How is cardiac troponin released from injured myocardium?
  • 2018
  • Ingår i: European Heart Journal-Acute Cardiovascular Care. - : Oxford University Press (OUP). - 2048-8726 .- 2048-8734. ; 7:6, s. 553-560
  • Tidskriftsartikel (refereegranskat)abstract
    • Cardiac troponin I and cardiac troponin T are nowadays the criterion biomarkers for the laboratory diagnosis of acute myocardial infarction due to their very high sensitivities and specificities for myocardial injury. However, still many aspects of their degradation, tissue release and elimination from the human circulation are incompletely understood. Myocardial injury may be caused by a variety of different mechanisms, for example, myocardial ischaemia, inflammatory and immunological processes, trauma, drugs and toxins, and myocardial necrosis is preceded by a substantial reversible prelethal phase. Recent experimental data in a pig model of myocardial ischaemia demonstrated cardiac troponin release into the circulation from apoptotic cardiomyocytes as an alternative explanation for clinical situations with increased cardiac troponin without any other evidence for myocardial necrosis. However, the comparably lower sensitivities of all currently available imaging modalities, including cardiac magnetic resonance imaging for the detection of particularly non-focal myocardial necrosis in patients, has to be considered for cardiac troponin test result interpretation in clinical settings without any other evidence for myocardial necrosis apart from increased cardiac troponin concentrations as well.
  •  
4.
  • Neumann, J. T., et al. (författare)
  • Application of High-Sensitivity Troponin in Suspected Myocardial Infarction
  • 2019
  • Ingår i: New England Journal of Medicine. - : MASSACHUSETTS MEDICAL SOC. - 0028-4793 .- 1533-4406. ; 380:26, s. 2529-2540
  • Tidskriftsartikel (refereegranskat)abstract
    • BackgroundData regarding high-sensitivity troponin concentrations in patients presenting to the emergency department with symptoms suggestive of myocardial infarction may be useful in determining the probability of myocardial infarction and subsequent 30-day outcomes. MethodsIn 15 international cohorts of patients presenting to the emergency department with symptoms suggestive of myocardial infarction, we determined the concentrations of high-sensitivity troponin I or high-sensitivity troponin T at presentation and after early or late serial sampling. The diagnostic and prognostic performance of multiple high-sensitivity troponin cutoff combinations was assessed with the use of a derivation-validation design. A risk-assessment tool that was based on these data was developed to estimate the risk of index myocardial infarction and of subsequent myocardial infarction or death at 30 days. ResultsAmong 22,651 patients (9604 in the derivation data set and 13,047 in the validation data set), the prevalence of myocardial infarction was 15.3%. Lower high-sensitivity troponin concentrations at presentation and smaller absolute changes during serial sampling were associated with a lower likelihood of myocardial infarction and a lower short-term risk of cardiovascular events. For example, high-sensitivity troponin I concentrations of less than 6 ng per liter and an absolute change of less than 4 ng per liter after 45 to 120 minutes (early serial sampling) resulted in a negative predictive value of 99.5% for myocardial infarction, with an associated 30-day risk of subsequent myocardial infarction or death of 0.2%; a total of 56.5% of the patients would be classified as being at low risk. These findings were confirmed in an external validation data set. ConclusionsA risk-assessment tool, which we developed to integrate the high-sensitivity troponin I or troponin T concentration at emergency department presentation, its dynamic change during serial sampling, and the time between the obtaining of samples, was used to estimate the probability of myocardial infarction on emergency department presentation and 30-day outcomes.
  •  
5.
  • Omland, T, et al. (författare)
  • Troponins in heart failure
  • 2015
  • Ingår i: Clinica chimica acta. - : Elsevier BV. - 1873-3492 .- 0009-8981. ; 443, s. 78-84
  • Tidskriftsartikel (refereegranskat)
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy