Dual-Energy Computed Tomography Compared to Lung Perfusion Scintigraphy to Assess Pulmonary Perfusion in Patients Screened for Endoscopic Lung Volume Reduction

Gietema, H. A. (author)
Walraven, K. H. M. (author)
Posthuma, R. (author)
show more...
Mitea, C. (author)
Slebos, D. J. (author)
Vanfleteren, Lowie E G W (author)
Gothenburg University,Göteborgs universitet,Institutionen för medicin,Institute of Medicine
show less...
 (creator_code:org_t)
2021-08-10
2021
English.
In: Respiration. - : S. Karger AG. - 0025-7931 .- 1423-0356.
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Background: Endoscopic lung volume reduction (ELVR) using one-way endobronchial valves is a technique to reduce hyperinflation in patients with severe emphysema by inducing collapse of a severely destroyed pulmonary lobe. Patient selection is mainly based on evaluation of emphysema severity on high-resolution computed tomography and evaluation of lung perfusion with perfusion scintigraphy. Dual-energy contrast-enhanced CT scans may be useful for perfusion assessment in emphysema but has not been compared against perfusion scintigraphy. Aims: The aim of the study was to compare perfusion distribution assessed with dual-energy contrast-enhanced computed tomography and perfusion scintigraphy. Material and Methods: Forty consecutive patients with severe emphysema, who were screened for ELVR, were included. Perfusion was assessed with 99mTc perfusion scintigraphy and using the iodine map calculated from the dual-energy contrast-enhanced CT scans. Perfusion distribution was calculated as usually for the upper, middle, and lower thirds of both lungs with the planar technique and the iodine overlay. Results: Perfusion distribution between the right and left lung showed good correlation (r = 0.8). The limits of agreement of the mean absolute difference in percentage perfusion per region of interest were 0.75-5.6%. The upper lobes showed more severe perfusion reduction than the lower lobes. Mean difference in measured pulmonary perfusion ranged from -2.8% to 2.3%. Lower limit of agreement ranged from -8.9% to 4.6% and upper limit was 3.3-10.0%. Conclusion: Quantification of perfusion distribution using planar 99mTc perfusion scintigraphy and iodine overlays calculated from dual-energy contrast-enhanced CTs correlates well with acceptable variability.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine (hsv//eng)

Keyword

Bronchoscopic lung volume reduction
Computed tomography
lung
Dual-energy computed tomography
Emphysema
Perfusion scan
Scintigraphy
endobronchial valve therapy
expert panel recommendation
ct
Respiratory System

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Gietema, H. A.
Walraven, K. H. ...
Posthuma, R.
Mitea, C.
Slebos, D. J.
Vanfleteren, Low ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
Articles in the publication
Respiration
By the university
University of Gothenburg

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view