SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Giovannella S.) srt2:(2007-2009)"

Sökning: WFRF:(Giovannella S.) > (2007-2009)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Anelli, M., et al. (författare)
  • Measurement and simulation of neutron detection efficiency in lead-scintillating fiber calorimeters
  • 2009
  • Ingår i: Nuclear physics B, Proceedings supplements. - : Elsevier BV. - 0920-5632 .- 1873-3832. ; 197:1, s. 353-357
  • Tidskriftsartikel (refereegranskat)abstract
    • The overall detection efficiency to neutrons of a small prototype of the KLOE lead-scintillating fiber calorimeter has been measured at the neutron beam facility of The Svedberg Laboratory, TSL, Uppsala, in the kinetic energy range [5-175] MeV. The measurement of the neutron detection efficiency of a NE110 scintillator provided a reference calibration. At the lowest trigger threshold, the overall calorimeter efficiency ranges from 30% to 50%. This value largely exceeds the estimated 8-15% expected if the response were proportional only to the scintillator equivalent thickness. A detailed simulation of the calorimeter and of the TSL beam line has been performed with the FLUKA Monte Carlo code. First data-MC comparisons are encouraging and allow to disentangle a neutron halo component in the beam.
  •  
2.
  • Anelli, M., et al. (författare)
  • Measurement of the detection efficiency of the KLOE calorimeter for neutrons between 22 and 174 MeV
  • 2009
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 598:1, s. 244-247
  • Tidskriftsartikel (refereegranskat)abstract
    • A prototype of the high-sampling lead-scintillating fiber KLOE calorimeter has been exposed to neutron beams of 21, 46 and 174 MeV, provided by the The Svedberg Laboratory, Uppsala, to test its neutron detection efficiency. The measurement of the neutron detection efficiency of an NE110 scintillator provided a reference calibration. The measured efficiency is larger than what expected considering the scintillator thickness of the KLOE prototype only. This result proves the existence of a contribution from the passive material to neutron detection efficiency, in a high-sampling calorimeter configuration.
  •  
3.
  • Anelli, A., et al. (författare)
  • Measurement and simulation of the neutron response and detection efficiency of a Pb-scintillating fiber calorimeter
  • 2008
  • Ingår i: IEEE Transactions on Nuclear Science. - 0018-9499 .- 1558-1578. ; 55:3, s. 1409-1412
  • Tidskriftsartikel (refereegranskat)abstract
    • We have measured the overall detection efficiency to neutrons of a small prototype of the KLOE Pb-scintillating fiber calorimeter in the kinetic energy range [5,175] MeV. using the neutron beam facility of The Svedberg Laboratory, TSL, Uppsala. The measurement of the neutron detection efficiency of a NE110 scintillator provided a reference calibration. At the lowest trigger threshold, the overall calorimeter efficiency ranges from 28% to 33%. This value largely exceeds the estimated similar to 8% expected if the response were proportional only to the scintillator equivalent thickness. A detailed simulation of the calorimeter and of the TSL beamline has been performed with the FLUKA Monte Carlo code. The simulated response of the detector to neutrons is presented together with first data to Monte Carlo comparison. The results show an overall neutron efficiency of about 35%. The reasons for such an efficiency enhancement, in comparison with the typical scintillator-based neutron counters, are explained, opening the road to a novel neutron detector.
  •  
4.
  • Anelli, M., et al. (författare)
  • Measurement and simulation of the neutron response and detection efficiency of a Pb-scintillating fiber calorimeter
  • 2007
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 581:1-2, s. 368-372
  • Tidskriftsartikel (refereegranskat)abstract
    • The overall detection efficiency to neutrons of a small prototype of the KLOE Pb-scintillating fiber calorimeter has been measured at the neutron beam facility of The Svedberg Laboratory, TSL, Uppsala, in the kinetic energy range 5-175 MeV. The measurement of the neutron detection efficiency of a NE110 scintillator provided a reference calibration. At the lowest trigger threshold, the overall calorimeter efficiency ranges from 40% to 50%. This value largely exceeds the estimated 8-16% expected if the response were proportional only to the scintillator equivalent thickness. A detailed simulation of the calorimeter and of the TSL beamline has been performed with the FLUKA Monte Carlo code. The simulated response of the detector to neutrons is presented, as well as a first data Monte Carlo comparison. The results show an overall neutron efficiency of about 50%, when no trigger threshold is applied. The reasons of such an efficiency enhancement, in comparison with the typical scintillator-based neutron counters, are explained, opening the road to a novel neutron detector.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy