  • Anguille, Sébastien, et al. (författare)
  • Dendritic cell vaccination as postremission treatment to prevent or delay relapse in acute myeloid leukemia
  • 2017
  • Ingår i: Blood. - : American Society of Hematology. - 0006-4971 .- 1528-0020. ; 130:15, s. 1713-1721
  • Tidskriftsartikel (refereegranskat)abstract
    • Relapse is a major problem in acute myeloid leukemia (AML) and adversely affects survival. In this phase 2 study, we investigated the effect of vaccination with dendritic cells (DCs) electroporated with Wilms’ tumor 1 (WT1) messenger RNA (mRNA) as postremission treatment in 30 patients with AML at very high risk of relapse. There was a demonstrable antileukemic response in 13 patients. Nine patients achieved molecular remission as demonstrated by normalization of WT1 transcript levels, 5 of which were sustained after a median follow-up of 109.4 months. Disease stabilization was achieved in 4 other patients. Five-year overall survival (OS) was higher in responders than in nonresponders (53.8% vs 25.0%; P 5 .01). In patients receiving DCs in first complete remission (CR1), there was a vaccine-induced relapse reduction rate of 25%, and 5-year relapse-free survival was higher in responders than in nonresponders (50% vs 7.7%; P < .0001). In patients age £65 and >65 years who received DCs in CR1, 5-year OS was 69.2% and 30.8% respectively, as compared with 51.7% and 18% in the Swedish Acute Leukemia Registry. Long-term clinical response was correlated with increased circulating frequencies of polyepitope WT1-specific CD81 T cells. Long-term OS was correlated with interferon-g1 and tumor necrosis factor-a1 WT1-specific responses in delayed-type hypersensitivity-infiltrating CD81 T lymphocytes. In conclusion, vaccination of patients with AML with WT1 mRNA-electroporated DCs can be an effective strategy to prevent or delay relapse after standard chemotherapy, translating into improved OS rates, which are correlated with the induction of WT1-specific CD81 T-cell response. This trial was registered at www.clinicaltrials.gov as #NCT00965224.
  •  
3.
  • Becker, Holger, et al. (författare)
  • Microfluidic system for the identification of bacterial pathogens causing urinary tract infections
  • 2015
  • Ingår i: Microfluidics, BioMEMS, and Medical Microsystems XIII. - : SPIE - International Society for Optical Engineering. - 9781628414103
  • Konferensbidrag (refereegranskat)abstract
    • Urinary tract infections (UTIs) are among the most common bacterial infections and pose a significant healthcare burden. The growing trend in antibiotic resistance makes it mandatory to develop diagnostic kits which allow not only the determination of a pathogen but also the antibiotic resistances. We have developed a microfluidic cartridge which takes a direct urine sample, extracts the DNA, performs an amplification using batch-PCR and flows the sample over a microarray which is printed into a microchannel for fluorescence detection. The cartridge is injection-molded out of COP and contains a set of two-component injection-molded rotary valves to switch between input and to isolate the PCR chamber during thermocycling. The hybridization probes were spotted directly onto a functionalized section of the outlet microchannel. We have been able to successfully perform PCR of E. coli in urine in this chip and perform a fluorescence detection of PCR products. An upgraded design of the cartridge contains the buffers and reagents in blisters stored on the chip.
  •  
4.
  •  
5.
  • Herman, Anne, et al. (författare)
  • Allergic contact dermatitis caused by isobornyl acrylate in Freestyle® Libre, a newly introduced glucose sensor
  • 2017
  • Ingår i: Contact Dermatitis. - : Wiley. - 0105-1873. ; 77:6, s. 367-373
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Glucose sensors, such as FreeStyle® Libre, are innovative medical devices developed for diabetes patients as a replacement for classic glucose meters, ensuring continuous glucose monitoring without the disadvantage of regular skin finger pricks. Objectives: To report several cases of allergic contact dermatitis caused by FreeStyle® Libre, and to report on isobornyl acrylate as a culprit allergen. Patients and Methods: Fifteen patients presented with allergic contact dermatitis caused by FreeStyle® Libre. All but 1 were patch tested with a baseline series, and with pieces and/or ultrasonic bath extracts of (the adhesive part of) the glucose sensor. Isobornyl acrylate was patch tested, in various concentrations and vehicles, in 13 patients. Gas chromatography–mass spectrometry (GC-MS) of the sensors was performed. Results: All patients reacted to the adhesive part of the sensor, and 12 patients were shown to be sensitized to isobornyl acrylate. Simultaneous reactions to other allergens were rarely observed. GC-MS showed the presence of isobornyl acrylate in the sensors. Conclusions: Cases of allergic contact dermatitis caused by FreeStyle® Libre are increasingly being observed, and isobornyl acrylate is a relevant culprit allergen. Cross-reactivity to other acrylates was infrequently observed, but other, hitherto unidentified, contact allergens may still be present in the device.
  •  
6.
  • Herman, Anne, et al. (författare)
  • Allergic contact dermatitis caused by isobornyl acrylate in the Enlite glucose sensor and the Paradigm MiniMed Quick-set insulin infusion set
  • 2019
  • Ingår i: Contact Dermatitis. - : Wiley. - 0105-1873 .- 1600-0536. ; 81:6, s. 432-437
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: The FreeStyle Libre glucose sensor has caused many cases of allergic contact dermatitis, and isobornyl acrylate (IBOA) in this sensor has been identified as one of the culprit allergens. Objectives: To report on the presence of IBOA in devices produced by Medtronic, namely, Enlite sensor and insulin infusion set Paradigm MiniMed Quick-set. Patients and Methods: Five patients reacting to the glucose sensor Enlite and/or the insulin infusion set Paradigm MiniMed Quick-set observed in three clinics (two Belgian and one Swedish) were patch tested with the baseline and other series, as well as with IBOA; four of them also with pieces of adhesive patches from the devices, and two with a thin layer chromatogram of Enlite glucose sensor extracts. Gas chromatography-mass spectrometry (GC-MS) analyses were performed. Results: Four patients reacted to IBOA and one to colophonium, a known allergen in Enlite, and three to the adhesive part of the sensor or the insulin infusion set. IBOA was identified in the sensor by GC-MS, and its presence was indicated in the infusion set. Conclusions: IBOA is a contact allergen in Enlite glucose sensor, and likely also in the infusion set. Therefore, these devices are not suitable alternatives for patients sensitized to the FreeStyle Libre sensor.
  •  
7.
  • Herman, Anne, et al. (författare)
  • The preservative 2-(thiocyanomethylthio)benzothiazole : A potential allergen in leather products
  • 2019
  • Ingår i: Contact Dermatitis. - : Wiley. - 0105-1873 .- 1600-0536. ; 81:4, s. 262-265
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Allergic contact dermatitis caused by leather is common, and several responsible allergens, such as tanning agents, glues, mercaptobenzothiazole derivatives, and dyes, but also antimicrobials and antifungals, are involved. Material and methods: Three female patients were referred to the Departments of Dermatology in a Belgian university hospital following skin reactions caused by leather products (shoes, belt, and car seats). They were patch tested with the European baseline series and samples of suspected leather products, and additionally with 2-(thiocyanomethylthio)benzothiazole (TCMTB), an antifungal agent previously reported to be a contact allergen in footwear. Chromatographic analyses of samples of all the leather materials tested were performed at the Department of Occupational and Environmental Dermatology in Malmö, Sweden. Results: The patients reacting to the leather samples were shown to be sensitized to TCMTB, the presence of which could be confirmed by chemical analyses of samples obtained from the patients. Conclusion: Patch tests with TCMTB should be considered in patients with contact dermatitis caused by leather items.
  •  
8.
  • Herman, Anne, et al. (författare)
  • Unexpected positive patch test reactions to sesquiterpene lactones in patients sensitized to the glucose sensor FreeStyle Libre
  • 2019
  • Ingår i: Contact Dermatitis. - : Wiley. - 0105-1873 .- 1600-0536. ; 81:5, s. 354-367
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Most diabetic patients sensitized to FreeStyle Libre react to isobornyl acrylate (IBOA), with a considerable number of them also showing unexpected positive patch test reactions to sesquiterpene lactone (SL) mix (SLM) tested in the baseline series. Objectives: To compile patch test results of subjects affected, and provide potential explanations for this association. Patients and Methods: Fifty-three Freestyle Libre-allergic patients were patch tested with IBOA and/or SLM, and several were also patch tested with the components of SLM. Chromatographic analyses were performed on the glucose sensor, IBOA, and the components of SLM. Results: Thirty-three patients reacted positively to the components of SLM, and 11 of 27 patients reacted positively to alantolactone, in particular. Gas chromatography-mass spectrometry (GC-MS) analyses did not detect these chemicals in the different parts of the glucose sensor, or in IBOA. Conclusion: Significant co-sensitizations between SLs on the one hand and the glucose sensor FreeStyle Libre and/or isobornyl acrylate on the other hand exist, without evidence of the presence of SLs via GC-MS analysis. Cross-reactions between them seem improbable. As a possible hypothesis, a common precursor for both, such as camphene, may exist. Highlights: Of the diabetic patients sensitized to the glucose sensor FreeStyle Libre and/or IBOA, 62.3% reacted positively to SLM. Cross-reactions between IBOA and the three components of SLM (alantolactone, costunolide, and dehydrocostus lactone) seem unlikely, because of their different spatial structures. Co-sensitization between IBOA and SLS can be explained by the fact that there is a common precursor, such as camphene, between these two molecules.
  •  