SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Gopal S) srt2:(2005-2009)"

Sökning: WFRF:(Gopal S) > (2005-2009)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Schael, S, et al. (författare)
  • Precision electroweak measurements on the Z resonance
  • 2006
  • Ingår i: Physics Reports. - : Elsevier BV. - 0370-1573 .- 1873-6270. ; 427:5-6, s. 257-454
  • Forskningsöversikt (refereegranskat)abstract
    • We report on the final electroweak measurements performed with data taken at the Z resonance by the experiments operating at the electron-positron colliders SLC and LEP. The data consist of 17 million Z decays accumulated by the ALEPH, DELPHI, L3 and OPAL experiments at LEP, and 600 thousand Z decays by the SLID experiment using a polarised beam at SLC. The measurements include cross-sections, forward-backward asymmetries and polarised asymmetries. The mass and width of the Z boson, m(Z) and Gamma(Z), and its couplings to fermions, for example the p parameter and the effective electroweak mixing angle for leptons, are precisely measured: m(Z) = 91.1875 +/- 0.0021 GeV, Gamma(Z) = 2.4952 +/- 0.0023 GeV, rho(l) = 1.0050 +/- 0.0010, sin(2)theta(eff)(lept) = 0.23153 +/- 0.00016. The number of light neutrino species is determined to be 2.9840 +/- 0.0082, in agreement with the three observed generations of fundamental fermions. The results are compared to the predictions of the Standard Model (SM). At the Z-pole, electroweak radiative corrections beyond the running of the QED and QCD coupling constants are observed with a significance of five standard deviations, and in agreement with the Standard Model. Of the many Z-pole measurements, the forward-backward asymmetry in b-quark production shows the largest difference with respect to its SM expectation, at the level of 2.8 standard deviations. Through radiative corrections evaluated in the framework of the Standard Model, the Z-pole data are also used to predict the mass of the top quark, m(t) = 173(+10)(+13) GeV, and the mass of the W boson, m(W) = 80.363 +/- 0.032 GeV. These indirect constraints are compared to the direct measurements, providing a stringent test of the SM. Using in addition the direct measurements of m(t) and m(W), the mass of the as yet unobserved SM Higgs boson is predicted with a relative uncertainty of about 50% and found to be less than 285 GeV at 95% confidence level. (c) 2006 Elsevier B.V. All rights reserved.
  •  
2.
  •  
3.
  • Govind, Satish C., et al. (författare)
  • Quantification of low-dose dobutamine stress using speckle tracking echocardiography in coronary artery disease
  • 2009
  • Ingår i: European Journal of Echocardiography. - : Oxford University Press (OUP). - 1525-2167 .- 1532-2114. ; 10:5, s. 607-612
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims We sought to evaluate the utility of speckle tracking echocardiography (STE) for detecting left ventricular (LV) mechanical abnormalities during low-dose (20 mu g) dobutamine stress (DSE). Methods and results Twenty-nine patients (56 +/- 12 years) with a history of recent acute coronary events (ACE) underwent STE-DSE. Left ventricular images, sampled at frame rates 70-100 Hz, were analysed off-line (Echopac BT 6.0.0). Velocity, strain, and rotational imaging were performed. Twenty patients had LV ejection fraction (EF) >40% (Group 1) whereas nine patients had LVEF <40% (Group 2). Average heart and frame rates were identical during DSE in the two groups (P = ns). Global circumferential strain (%) was significantly lower in Group 2 compared with Group 1 (10.65 +/- 5.30 vs. 16.82 +/- 6.61; P < 0.05) at rest and during peak stress (14.72 +/- 6.51 vs. 21.13 +/- 7.2; P < 0.05). The global peak rotation rate (degree/s) was, however, higher at rest in Group 2 (70 +/- 97 vs. 19 +/- 67; P < 0.05) and 20 mu g stress. Peak systolic velocity increased in three of the four LV walls at 20 mu g ( in Groups 1 and 2). A global rotational rate increased significantly at 20 mu g during systole in both the groups, but was unchanged in Group 2 during diastole. Conclusions Speckle tracking echocardiography dobutamine stress appears to provide comprehensive information on LV mechanical status in the aftermath of ACE. The modality may help risk stratify such patients.
  •  
4.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy