Improved accuracy and extended flow range for a Fleisch pneumotachograph
-
Strömberg, N O (författare)
-
- Grönkvist, Mikael J. (författare)
- Swedish Defence Research Agency,National Defense Research Establishment, Division of Human Sciences, Aviation Medicine, Linköping, Sweden
-
- Strömberg, Tomas, 1966- (författare)
- Linköpings universitet,Institutionen för medicinsk teknik,Tekniska högskolan
-
(creator_code:org_t)
- 1999
- 1999
- Engelska.
-
Ingår i: Medical and Biological Engineering and Computing. - 0140-0118 .- 1741-0444. ; 37:4, s. 456-460
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.1...
-
https://urn.kb.se/re...
-
visa färre...
Abstract
Ämnesord
Stäng
- A large linear flow range and a small instrumental dead space volume are incompatible properties for a pneumotachometer (PTM). The linearity of a Fleisch number 2 PTM is studied for flows up to 6 litre s-1 (nominal range 0-2 litre s-1) with various up- and downstream geometries. It is hypothesised that using an array of calibration factors (conductance; flow/pressure), instead of a single calibration factor over the entire flow range, could improve accuracy and also extend the applicable flow range. The conductance against pressure characteristics are calculated with a previously described weighted averaging technique based on multiple strokes from a precision syringe. A single conductance value gives stroke volume errors in the range of -5 to 3% (0-2 litre s-1) and -6 to 11% (0-6 litre s-1) for validation using the same geometry as for calibration. The pressure dependent conductance improves accuracy to within -3% and 1% independent of flow range. However, for validation using a different geometry than for calibration, errors range from -5% to +8%. The degree of non-linearity varies between the geometries (range 3-15%) and is highest when using a one-directional valve upstream of the PTM and a Y-shaped connector. In conclusion, a pressure-dependent conductance improves accuracy and can also be used to extend the applicable flow range up to at least three times the nominal flow range.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Medicinska och farmaceutiska grundvetenskaper -- Fysiologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Basic Medicine -- Physiology (hsv//eng)
Nyckelord
- Conductance
- Flow calibration
- FIowmeter
- Extended flow range
- MEDICINE
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas