1.
  • Gustafsson, Ola, et al. (författare)
  • Heat exchanger design aspects related to noise in heat pump applications
  • 2016
  • Ingår i: Applied Thermal Engineering. - : Elsevier. - 1359-4311 .- 1873-5606. ; 93, s. 742-749
  • Tidskriftsartikel (refereegranskat)abstract
    • An increased use of heat pumps is one of the measures that can be taken to reduce energy consumption on a large scale. For a wider acceptance, and major heat pump market expansion, it is crucial to develop heat pumps that cause minimal disturbance. Results from field measurements made by SP Technical Research Institute of Sweden indicate that the use of indirect heat pumps has potential to significantly reduce the outdoor noise level of ambient air heat pumps. The noise level caused by such heat pumps has been shown to be highly influenced by the design of the air-to-fluid heat exchanger. The overall purpose of this study is to propose a design of an air-to-fluid heat exchanger that allows for a well performing system as well as a low level of noise and cost. Two different types of heat exchangers, with flat tubes and round tubes, are compared theoretically. According to the modelling results, a heat exchanger with flat tubes and plain fins is the most suitable out of the studied designs due to its low heat transfer resistance on the tube side. The round tube heat exchangers showed to be significantly less suitable, displacing more than twice the volume.
  •  
2.
  • Haglund Stignor, Caroline, et al. (författare)
  • New type of energy efficient heat exchanger for indirectly cooled display cabinets - Laboratory and field tests
  • 2018
  • Ingår i: Refrigeration Science and Technology. - 9782362150241 ; , s. 206-214
  • Konferensbidrag (refereegranskat)abstract
    • In this study, a completely new type of air-to-liquid heat exchanger, adapted for obtaining good heat transfer performance even at a laminar flow regime on the liquid side has been evaluated in a display cabinet application. The heat exchanger consists of parallel plates, with liquid in every second passage and air in the other passages. Tests were performed with a traditional open vertical display cabinet, first with a traditional finned-tube coil and thereafter with the new type of heat exchanger, both in a climate chamber and thereafter in the field. The results from both tests showed that the liquid inlet temperature could be increased by around 6°C, from the range -8°C - -7°C with the traditional coil to the range -2°C -1°C with the new type of heat exchanger, which can lead to considerable energy savings and operation without the need for defrosting of the heat exchanger.
  •  
Skapa referenser, mejla, bekava och länka